  • Page 1 Z-3080 CCD Barcode Scanner Multi-Interface User’s Manual ZBA Inc 94 Old Camplain Road Hillsborough NJ 08844 Phone: 908-359-2070 Fax: 908-359-1272 Web: http://www.zbausa.com/...
  • Page 2 NOTICE The issuer of this manual has made every effort to provide accurate information contained in this manual. The issuer shall not be held liable for any technical and editorial omissions or errors made herein; nor for incidental consequential damages resulting from the furnishing, performance or use of this material.
  • Page 3 INSTALLATION Keyboard Wedge 1. Turn off the PC 2. Disconnect the keyboard cable from the PC. 3. Connect the Keyboard Cable to the scanner and connect the scanner cable to the PC 4. Turn the terminal/computer power on. 5. You are ready use the scanner RS-232 1.
  • Page 4: Table Of Contents

    TABLE OF CONTENTS Introduction............1 Default Parameters ..........2 Program Procedure..........5 System Setting ........... 6 General Configuration Scanning Mode Selection........9 Inter- Message Delay ........10 Inter- Character Delay........11 Message/ Block Mode Selection......11 Beeper Tone Selection ........12 Interface Configuration RS-232C Serial Communication Parameters Setting Handshaking Protocol.......
  • Page 5: Introduction

    1. INTRODUCTION Chinese Post Code Parameters Setting....32 UPC/ EAN/ JAN Parameters Setting ....33 Scanning a series of programming bar code labels can Coda bar/ Monarch Parameters Setting....37 configure the series scanners. This allows decoding Code 128 Parameters Setting ......37 options and interface protocols to be tailored to a MATRIX 25 Parameters setting ......38 specific application.
  • Page 6: Default Parameters

    3. DEFAULT PARAMETERS DEFAULT VALUES OF KEYBOARD EMULATION PARAMETERS SETTING This table gives the default settings of all the Function Default Values programmable parameters. The default settings will be Keyboard type selection IBM PC/AT USA restored whenever the "Reset" programming label is Message terminator Enter/ carriage scanned and the laser scanner is in programming mode.
  • Page 7: Program Procedure

    DEFAULT VALUES OF DECODING PARAMETERS PROGRAM PROCEDURE USING BARCODE MENUS Function Code Default Value Code 39 Enable ITF 2 of 5 Enable Chinese Post Code Disable UPC/EAN/JAN Enable Coda bar Enable Reading codes ¡ ° Disable Selection Code 128 Enable Code 93 Enable ¡...
  • Page 8: System Setting

    Start of Configuration Ÿ The reading of the "RESET” label turns parameters back to default values. Ÿ When you intend to turn your scanner back RESET default parameter, please scans "Start configuration" label first, then scan "RESET" label The reading of the "ABORT" label discards ABORT...
  • Page 9: General Configuration

    Start of Configuration SCANNING MODE SELECTION (for laser scanner) For series laser scanners, there are 3 scanning modes to suit your application requirements. The scanner becomes inactive soon data transmitted. must triggered to become active Trigger Mode again. The scanner will light up when press the pulse mode trigger switch once.
  • Page 10: Inter-Message Delay

    INTER-CHARACTER DELAY This option governs delay time between consecutive characters. Scanning the following labels can alter the Start of Configuration delay time. DATA REDUNDANT CHECK The option allows you to set None decoder data redundant check. Enable 10 msec Disable 20 msec INTER-MESSAGE DELAY These series of scanners allow you to add a delay...
  • Page 11: Beeper Tone Selection

    SOUND DURATION Start of Configuration long(120 ms) SEND COMMAND IN BLOCK MODE COMMUNICATION You can use this option to set your own “Sen d” command used in block mode communication. Medium(50 ms) Enable Short(20 ms) Disable Very short(5 ms) *For Alpha-70 and SC-2070 Series only Medium and disable setting available, it’s hardware beeper Store control.
  • Page 12: Interface Configuration

    Start of Configuration 1. RS-232C SERIAL COMMUNICATION PARAMETERS SETTING The RS-232C scanner supports four handshaking protocols. With these options of communication protocol, you can tailor the scanner to meet the requirement of most systems HANDSHAKING PROTOCOL None RTS/CTS INTERFACE ACK/NAK CONFIGURATION Xon/Xoff ACK/NAK RESPONSE TIME SETTING...
  • Page 13: Baud Rate

    DATA BIT Start of Configuration ACK/NAK RESPONSE TIME SETTING (Cont’d) 3 sec STOP BIT 1 sec 5 sec BAUD RATE PARITY 19200 Even 9600 4800 Mark 2400 Space 1200 None End of Configuration...
  • Page 14: Message Terminator

    2. KEYBOARD EMULATION PARAMETERS SETTING Start of Configuration KEYBOARD TYPE SELECTION MESSAGE TERMINATOR (FOR RS-232C TYPE The keyboard emulation scanners can emulate a number of ONLY) personal computers keyboard and a number of terminal keyboard. Keyboard emulation is activated whenever you have selected the type of keyboard for which the scanner is going to emulate.
  • Page 15 KEYBOARD LANGUAGE SELECTION Start of Configuration KEYBOARD TYPE SELECTION (Cont’d) NEC 9801 IBM 3196 Terminal French APPLE MAC II( ¡ ° ) Spanish IBM 3477/3472 Terminal Italian PS2/30/56 Swiss IBM 3477 Terminal (Without break code) Swedish NEC 5200( ¡ ° ) Note: The configuration of the items with asterisk ( ¡...
  • Page 16: Keyboard Type Selection

    FUNCTION KEY ACTIVE ON/ OFF (FOR IBM AT USE) Function keys can be concatenated with input data as header and/or trailer. See table on page 40. MESSAGE TERMINATOR (FOR KEYBOARD WEDGE USE) None CAPITAL LOCK ON/ OFF Return /Enter Select the suitable code to match your keyboard caps lock status.
  • Page 17: Wand Emulation Parameters Setting

    EMULATION DATA OUTPUT SELECTION The decoded data output logic level can be set to befit Start of Configuration the external decoder. 00H~1FH ASCII Code defined Black = High Alt-mode code Black = Low WAND EMULATION NARROW/WIDE RATIO Crtl+code WAND EMULATION PARAMETERS SETTING CURSOR PAD WORK AT NUMLOCK...
  • Page 18: Usb Interface Parameters Setting

    Start of Configuration INTERFACE PARAMETERS SETTING The USB mode is effectively a keyboard emulator that works with hosts that USB-compatible operating system and USB ports. USB compatible operating systems are Windows 98, Windows NT 5.0 and later, no additional software is needed since the USB driver support is built into this operating system.
  • Page 19: Reading Code Selection

    Start of Configuration Code 128 Disable READING CODE SELECTION MSI Enable Code 39 Enable MSI Disable Code 39 Disable Code 93 Enable Coda bar Enable Code 93 Disable Coda bar Disable IATA Enable UPC/ EAN/ JAN Enable IATA Disable UPC/ EAN/ JAN Disable EAN- 128 Enable ITF 2 of 5 Enable EAN-128 Disable...
  • Page 20: Code 39 Parameters Setting

    Start of Configuration CONCATENATION READING CODE SELECTION (Cont’d) Enable Italian Pharmacy Enable Disable Italian Pharmacy Disable INTERLEAVED 2 OF 5 PARAMENTERS SETTING Examples: Felting length 4 to 8 digits CODE 39 PARAMETERS SETTING LENTGTH CHARACTER SET Scan:. Start of configuration Standard Code 39 Full ASCII Code 39 START/STOP CHARACTER TRANSMISSION...
  • Page 21: Chinese Post Code Parameters Setting

    CHECK DIGIT Start of Configuration CHECK DIGIT Calculate and Transmit Calculate but not Transmit Calculate and Transmit UPC/EAN/JAN PARAMETERS SETTING FORMAT Calculate but not Transmit CHINESE POST CODE PARAMETERS SETTING LENGTH EAN-8 or EAN-13 Scan:. Start of configuration UPC-A and EAN-13 UPC-A and UPC-E UPC-A End of...
  • Page 22 FORCE UPC-A TO EAN-13 FORMAT Start of Configuration UPC/EAN/JAN PARAMETERS SETTING (Cont’d) EAN-13 TRANSMIT UPC-A LEADING CHARACTER EAN-8 ADDENDUM TRANSMIT UPC-A CHECK DIGIT 5 Characters 2 Characters 2 or 5 Characters TRANSMIT UPC-E LEADING CHARACTER FORCE UPC-E TO UPC-A FORMAT End of Configuration...
  • Page 23: Codabar/ Monarch Parameters Setting

    CODABAR/ MONARCH PARAMETERS SETTING START/ STOP CHARACTER TRANSMISSION Start of Configuration TRANSMIT UPC-E CHECK DIGIT A, B, C, D DC1~DC4 TRANSMIT EAN-13 CHECK DIGIT a/ t, b/ n, c/ *, d/ e CONCATENATION Enable TRANSMIT EAN-8 CHECK DIGIT Disable CODE 128 PARAMETERS SETTING FNC 2 CONCATENATION Enable Disable...
  • Page 24: Matrix 25 Parameters Setting

    MSI/PLESSY PARAMETERS SETTING Examples: Felting length 4 to 8 characters Start of Configuration Scan:. Start CODE 128 PARAMETERS SETTING (Cont’d) configuration CHECK DIGIT End of configuration Calculate but not Transmit Double Check digit Calculate and Transmit UCC/EAN128 PARAMETERS SETTING The character FNC1 can be transmitted or not using Calculate but not Transmitted these codes.
  • Page 25: Italian Pharmacy Parameters Setting

    BARCODE LENGTH SETTING CODE 39 LENGTH SETTING Start of Configuration MSI/PLESSY PARAMETERS SETTING (Cont’d) PLESSY CODE SETTING CODE 93 LENGTH SETTING Calculated and transmitted Calculate but not transmitted CHECK DIGHT CODE 128 LENGTH SETTING Calculate and Transmit CODABAR LENGTH SETTING Calculate but not Transmit ITALIAN PHARMACY PARAMETERS SETTING TRANSMIT "A"...
  • Page 26: Isbn/ Issn Conversion

    Start of Configuration ISBN/ ISSN CONVERSION The function convents the UPC/EAN codes appearing on books and magazine not ISBN/ISSN format. ACTIVE ISBN/ ISSN INACTIVE ISBN/ ISSN DATA EDITING End of Configuration...
  • Page 27: Header And Trailer

    BARCODE IDENTIFIER CODE SETTING Each of the series type scanners can set max.2 digits as barcode identifier code according to different barcode. Start of Configuration The procedure is as follows: 1. Scan “Start of configuration” label HEADER AND TRAILER 2. Scan “Barcode identifier setting code” label. This option allows you to append a header and/or a trailer to 3.
  • Page 28: Truncate Header/Trailer Character

    Truncate Header/Trailer Character (Version az1.24, dz1.05, ac1.01, dz1.05,pl1.39 Start of Configuration Or higher is required) You can truncate a number header or trailer for a BARCODE IDENTIFIER CODE SETTING (Cont’d) symbology. When you do, the specific character you select is deleted from the symbology you want.
  • Page 29: Appendixes

    APPENDIX A CODE 39 FULL ASCII CODE TABLE CODE VALEUR CODE VALEUR ASCII ASCII HEXA. HEXA. & APPENDIXES < > "...
  • Page 30 APPENDIX A APPENDIX A CODE 39 FULL ASCII CODE TABLE FUNCTION KEY EMULATION CODE VALEUR CODE VALEUR FUNCTION CODE FUNCTION CODE ASCII ASCII ASCII ASCII HEXA. HEXA. Home Down Left Backspace Enter(num) Right PgUp Enter PgDn Ctl(L) shift Alt(L) 5 (num)
  • Page 31: Code 39 Full Ascii Barcode Table

    APPENDIX B APPENDIX B CODE 39 FULL ASCII BARCODE TABLE CODE 39 FULL ASCII BARCODE TABLE Start of Configuration (Enter)(num) 5 (num) (Up) (Right) (F1) (Ins) (Down) (PgUp) (F2) (Del) (Left) (Enter) (F3) (Home) (Backspace) (PgDn) (F4) (End) (TAB) shift(L) (F5) End of Configuration...
  • Page 32 APPENDIX B APPENDIX B CODE 39 FULL ASCII BARCODE TABLE CODE 39 FULL ASCII BARCODE TABLE Start of Configuration (F6) (ESC) (F7) Ctl (L) & (F8) Alt (L) (F9) (F10) (F11) " (F12) End of Configuration...
  • Page 33 APPENDIX B APPENDIX B CODE 39 FULL ASCII BARCODE TABLE CODE 39 FULL ASCII BARCODE TABLE Start of Configuration < > End of Configuration...
  • Page 34 APPENDIX B APPENDIX B CODE 39 FULL ASCII BARCODE TABLE CODE 39 FULL ASCII BARCODE TABLE Start of Configuration End of Configuration...
  • Page 35 APPENDIX B APPENDIX B CODE 39 FULL ASCII BARCODE TABLE CODE 39 FULL ASCII BARCODE TABLE Start of Configuration End of Configuration...
  • Page 36: Appendix D Quick Settings

    APPENDIX C APPENDIX D BARCODE SAMPLES QUICK SETTINGS Code 39 1. Quick Settings for Keyboard Wedge Mode Program Reset Code 128 PC/AT C O D E 2. Quick Settings for RS 232 Mode Interleaved 2 of 5 Program Reset 1 2 3 4 5 6 7 8 9 0 RS-232C Coda bar(NW-7) 3.