Outlet connection width is 1 inch - Mounting bracket width is 1½ inch.
For complete dimensional information, see CAPS submittal drawings.
All dimensions are in inches.
Performance Data
Model
RPM
Amps
Watts
2,3,5
SP-A50
700
0.31
2,3,5
SP-A70
850
0.27
2,3,5
SP-A90
900
0.34
2,3,4,5,6
SP-A110
950
0.58
2,3,5,6
SP-A125
1100
0.62
3,4,5,6
SP-A190
1400
1.30
3,5
SP-A200
900
0.43
3,5
SP-A250
1000
0.77
3,4,5
SP-A290
1050
0.72
3,4,5
SP-A390
1350
1.34
3
SP-A410
1000
1.74
3,4
SP-A510
1070
3.30
3
SP-A700
1100
3.20
3
SP-A710
1080
4.40
3,4
SP-A780
1600
3.30
3
SP-A900
950
4.00
3,4
SP-A1050
1095
6.30
3
SP-A1410
1450
7.40
3,4
SP-A1550
1610
8.60
1 HVI sones at 0.1 wg
3 Available with CRD - Ceiling Radiation Damper
2 Available with light
4 Available with 50 Hz motors
Performance certified is for Model SP exhaust for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft damper. Speed
(RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5m) in a hemispherical free field calculated
per AMCA Standard 301. Values are for installation type B: free inlet fan sone levels.