Nordyne E2EH-xxx HB Series Owner's Manual & Installation Instructions page 31

Downflow, upflow electric furnaces
Table of Contents

Advertisement

5-Wire Thermostat
W
Wire
nuts
1
2
E2EB FURNACE Control Plug
(6-pin matrix)
2-Wire Thermostat
W
Wire
nuts
1
2
E2EB FURNACE Control Plug
(6-pin matrix)
Figure 31. E2EB Thermostat Connection
Wire from furnace to Platinum unit
Red and white
Yellow
t-stat wire
connected by
OEM
Platinum installer
disconnects
white and red
t-stat wires
PLATINUM
Grey or Green
White
Orange or Red
Yellow
Figure 32. E2 Furnace Low Voltage Wiring if Installed with Platinum Series Models
Y RC RH G
Wire
To A/C
nuts
3
4
5
6
R
Unstripped
Wires
Wire
nuts
3
4
5
6
PLATINUM
Green
Black
White
Red
Yellow or Blue
Yellow or Blue
White
Y
W
G
R
Green
Red
THERMOSTAT
Wire from thermostat
to furnace
Wire from furnace to
Platinum unit
Yellow or Blue
White
Y
W
G
R
Green
THERMOSTAT
Red
Wire from thermostat
to furnace
4-Wire Thermostat
W
Y
R
G
To A/C
1
2
3
4
5
6
E2EB FURNACE Control Plug
(6-pin matrix)
Heat Pump Thermostat
G
R W
C
E
O
Y
2
1
2
3
4
5
6
E2EB FURNACE Control Plug
(6-pin matrix)
Typical AC
FURNACE
Grey
White
Red
Green
Typical HP
Green
White
Red
Yellow or Blue
FURNACE
Grey
White
Red
Green
To
H/P
31