Control Board; Pressure Control Transducer; Pressure Adjust Potentiometer - Graco 3A0243A Repair Manual

Airless sprayers 3300 psi (22.8 mpa, 228 bar) maximum working pressure
Table of Contents

Advertisement

Pressure Control
Removal
1.
Remove two screws (71) and swing down
cover (130a).
2.
Remove strain relief bushings (130r and 123).
3.
Disconnect at control board (130b):
Lead from potentiometer (130d)
Lead from transducer (66)
Lead from WatchDog switch (130g)
Lead from pump ON/OFF switch (130f)
Lead from gallon counter sensor (39)
Display connector (130m)
Engine, ground and clutch wires
4.
Remove four screws (130c) and control board (130b).
Removal
1.
Remove two screws (71) and swing down
cover (130a).
2.
Disconnect transducer (66) lead from control board
(130b).
3.
Pull transducer connector through rubber grommet (113).
Removal
1.
Remove two screws (71) and swing down
cover (130a).
2.
Disconnect potentiometer (130d) lead from control board
(130b).
3.
Loosen set screws on potentiometer knob (130h) and
remove knob, shaft nut, lock washer and potentiometer
(130d).
4.
Remove shaft spacer (130e) from potentiometer.
22

Control Board

Pressure Control Transducer

Pressure Adjust Potentiometer

Installation
1.
Install control board (130b) with four screws (130c).
2.
Connect engine wires to control board (130b).
3.
Connect at control board (130b):
Ground and clutch wires
Display connector (130m)
Lead from gallon counter sensor (39)
Lead from pump ON/OFF switch (130f)
Lead from WatchDog switch (130g)
Lead from transducer (66)
Lead from potentiometer (130d)
4.
Install new strain relief bushings (123 and 130r).
5.
Swing up cover (130a) and secure with two screws (71).
4.
Remove pressure control transducer (66) and o-ring (67)
from filter housing (72).
Installation
1.
Install o-ring (67) and pressure control transducer (66) in
filter housing (72). Torque to 35 - 45 ft-lb.
2.
Install transducer connector and rubber grommet in con-
trol housing.
3.
Connect transducer (66) lead to control board (130b).
4.
Swing up cover (130a) and secure with two screws (71).
Installation
1.
Install shaft spacer (130e) on potentiometer (130d).
2.
Install potentiometer, shaft nut, lock washer and potenti-
ometer knob (130h).
a.
Turn potentiometer shaft clockwise to internal stop.
Assemble potentiometer knob (130h) to strike pin on
cover (130a).
b.
After adjustment of step a., tighten both set screws in
knob 1/4 to 3/8 turn after contact with shaft.
3.
Connect potentiometer lead to control board (130b).
4.
Swing up cover (130a) and secure with two screws (71).
After a fault, follow these steps to restart sprayer:
1.
Correct fault condition.
2.
Turn sprayer OFF.
3.
Turn sprayer ON.
3A0243A

Hide quick links:

Advertisement

Table of Contents
loading