Back Panel – Power Supply
1. Remote trigger + 14 VDC to control external amplifier power on
2. Remote trigger + 14 VDC to control external amplifier power on
3. Fuse 1 amp Slow Blow – main power fuse
4. IEC AC power input connector
5. Fuse 1 amp Slow Blow – secondary high voltage and filament fuse
6. 8 pin multi conductor power cable to preamp section
7. 120V/50 Hz – 60 Hz
8. 240V/50 Hz – 60 Hz
9. Serial Number
Power Supply Meter Bulb Replacement Guide
The lamps (bulbs) that back light the voltage and current meters in the SLP 05 power supply may require
service from time to time. These lamps are incandescent filament bulbs. The type of lamp is specified as
Festoon Lamp with a 12 volt 1.2 watt rating. These lamps are available from Cary Audio Design should the
occasion arise that replacements become necessary.
To service meter bulbs:
1. Remove the AC power cord from the rear of the SLP 05 power supply.
2. Remove the multi-conductor preamp power cord as well and lay the power supply upside down
on a soft towel.
3. Unscrew the 12 # 6:32 Philips head screws from the bottom plate of the power supply
4. Remove the bottom plate and avoid touching the power connections.
5. With a small Jeweler's Philips screwdriver remove the two screws from the rear of the meter. Look
to the drawing for location of the screws marked with the letter A.
6. Now you can simply push the Festoon lamp up and out of the spring metal fingers.
7. Replace the lamp and simply reverse the above directions.
11