Troubleshooting - Graco 1K Ultra–Lite 243482 Instructions-Parts List Manual

Air operated, single component dispense valve
Table of Contents

Advertisement

WARNING
SKIN INJECTION HAZARD
To reduce the risk of serious injury
whenever you are instructed to relieve
pressure, always follow the Pressure
Relief Procedure on page 8.
PROBLEM
Valve does not open
Valve does not close
(leaks)
Higher
than
normal
back-pressure
10
308876

Troubleshooting

CAUSE
Insufficient air pressure
Air not exhausted from behind air cylin-
der piston
Shaft adjustment too far closed
Insufficient air pressure
Air not exhausted from behind air cylin-
der piston
Blockage between needle and seat
Bad or missing gasket between seat
and housing
Needle worn out
Nosepiece plugging up
1. Relieve the pressure.
2. Check all possible causes to the problem before
disassembling the pump.
SOLUTION
Turn on or turn up air pressure.
Use four-way, relieving-type air valve operator.
Adjust the shaft stroke as instructed on page 9.
Turn on or turn up air pressure.
Use four-way, relieving-type air valve operator.
Remove and clean needle and seat.
Replace gasket (38).
Replace needle and seat.
Remove and clean.