Parity Disable Jumper; Data Compression On Switch; Power Connector; Scsi 68 Pin Connector - Sony SDX-1100V/R User Manual

Ait-5
Table of Contents

Advertisement

3.1.3. Parity Disable Jumper

Parity check function can be disabled by Jumper. Parity check is disabled while left end jumper is installed. Parity
generate function is always enabled.
Parity
Disable
Enable
: = OPEN
| = CLOSED

3.1.4. Data Compression ON Switch

Data compression can be selected by DIP switch.
DC Control-1
DC Control-2
OFF
OFF
ON
ON

3.1.5. Power Connector

The power connector is illustrated as Figure 3-4.

3.1.6. SCSI 68 pin Connector

Figure 3-5 illustrates SCSI 68 pin connector, and table 3-4 shows the assignments for the pins of the connector.
SDX-1100V supports both Low-Voltage-Differential SCSI configuration as shown table 3-4 and Single-Ended SCSI
configuration as shown table 3-5. SDX-1100V detects and switches SCSI configuration between
Low-Voltage-Differential and single-ended modes by monitoring DIFFSENS signal assigned pin 16 in SCSI bus.
(Refer to table 3-4)
SONY AIT-5 drive SDX-1100V series Ver.1.0
Setting
|
:
Jumper not installed
Jumper installed
Table 3-3: Data Compression Switches
OFF
Compression disabled at power-on. The host is allowed to control
compression.
ON
Compression disabled at power-on. The host is not allowed to
control compression.
OFF
Compression enabled at power-on. The host is allowed to control
compression.
ON
Compression enabled at power-on. The host is not allowed to
control compression.
4
3
5V
GND
Figure 3-4: Power Connector
Pin 34
Pin 68
Figure 3-5: Non-shielded SCSI Device Connector
Definition
2
1
GND
12V
1
35
3.Installation