Safe Operation; Emission Control - Echo PB-460LN Operator's Manual

Serial number 02001001 - 02999999
Hide thumbs Also See for PB-460LN:
Table of Contents

Advertisement

6

SAFE OPERATION

Do not operate this product indoors or in inadequately ventilated areas. Engine exhaust contains poisonous
emissions and can cause serious injury or death.
Determine Operation Area
• Review area to be cleared. Look for potential hazards such as stones
or metal objects.
• Take wind conditions into account: avoid open doors and windows.
• Do not point blower at people or animals.
• Start unit on ground with throttle at idle. Check that blower pipe is
not blocked by the ground or by any objects.
Read the Manuals
• Provide all users of this equipment with the Operator's Manual and
Safety Manual for instructions on Safe Operation.
Keep A Firm Grip
• Hold handle with fingers together encircling the handle.
Clear the Work Area
• Spectators and fellow workers must be warned, and children and
animals prevented from coming nearer than 15 m (50 ft.) while the unit
is in use.
Keep A Solid Stance
• Maintain footing and balance at all times. Do not stand on slippery,
uneven or unstable surfaces. Do not work in odd positions or on
ladders.
• Do not perform Maintenance or Assembly procedures with engine
running.
E
C
MISSION
ONTROL
EPA Phase 2
The emission control system for this engine is EM/TWC (Engine
Modification and Catalyst).
An Emission Control Label is located on the unit. (This is an EX-
AMPLE ONLY, information on label varies by engine FAMILY).
The 300 hour emission durability compliance period is the time span selected by the manufacturer certifying the
engine emissions output meets applicable emissions regulations, provided that approved maintenance procedures are
followed as listed in the Maintenance Section of this manual.
WARNING
PRODUCT EMISSION DURABILITY
DANGER
Noise Control
• Follow local noise regulations on sound
levels and hours of operations. Use only
during appropriate hours.
• Never use a higher speed setting then
necessary to perform a task. The higher
the engine speed the louder the blower
noise.
• Be a good neighbor.
Avoid Hot Surfaces
• During operation, the muffler or catalytic
muffler and surrounding cover may
become extremely hot. Avoid contact
during and immediately after operation.
Always keep exhaust area clear of
flammable debris.
IMPORTANT ENGINE INFORMATION
ENGINE FAMILY: 4EHXS.0444CA DISPLACEMENT: 44.0
EMISSION COMPLIANCE PERIOD : 300 HRS.
THIS ENGINE MEETS U.S. EPA PH2 AND 2000 AND LATER
CALIFORNIA EMISSION REGULATIONS FOR S.O.R.E. REFER
TO OWNER'S MANUAL FOR MAINTENANCE SPECIFICA-
TIONS AND ADJUSTMENTS.