4.4.

GSM Control

4.4.1.

Overview

User application could communicate with GSM module of BETA903A by COM1 with the
following settings:
Baud rate = 57600, Data bit = 8, Stop bit = 1, No parity.
After opening COM1, user could send AT command to control the GSM module. Here is some
AT commands used in our example application:
AT command
ATA
ATH
ATD<n>
AT^SNFS=<n>
*More detailed description about AT command could be found at document "MC55i AT
Command Set" of Siemens.
BETA903A USER MANUAL
Description
Answer a call.
Disconnect existing call.
Set up an outgoing call.
<n>: phone number.
Set the audio mode required for the connected equipment.
The audio mode should be set to 2 for GSM module of BETA903A.