Download Print this page

American Standard ELLISSE OVAL 2709 Installation Instructions

Whirlpool / bathing pool

Advertisement

Quick Links

INSTALLATION INSTRUCTIONS

ELLISSE OVAL™
HIGH GLOSS ACRYLIC
2709.XXXW SERIES WHIRLPOOL / BATHING POOL
240 mm
(9-7/16)
305mm(12) X 229mm(9)
CUTOUT IN FLOOR FOR DRAIN
978 mm
(38-1/2)
489mm
(19-1/4)
76mm
(3)
C L OF DRAIN
OUTLET
SAFE-T-HEATER
REMOVABLE BLANK
86mm
(3-3/8)
38mm
(1-1/2)
502mm
(19-3/4 )
464mm
(18-1/4)
1-1/2 N.P.T.M.
THREADS
1-1/2 O.D.
TAILPIECE
GENERAL SPECIFICATIONS FOR 2709 WHIRLPOOL
69-1/4 x 38-1/2 x 19-3/4 In.(1759 x 978 x 502mm)
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT 3 )
WHIRLPOOL ELECTRICAL SPECIFICATIONS
SYSTEM II PUMP
GENERAL INSTALLATION INFORMATION
Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor
immediately.
After inspection and during installation, protect the bath from construction damage. After installation, and before
enclosing with wallboard, tile, etc., water test the unit and check for leaks.
Do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect
the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump,
motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and
enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead
(required for recess installations).
Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.
WARNING! Do not lift whirlpool by the piping harness at any time.
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
751753-100 Rev. L
1759 mm
(69-1/4)
OUTLINE OF
CUTOUT
ON/OFF
SWITCH
PUMP
PROVIDE ACCESS
TO PUMP FOR
SERVICING ON ALL
INSTALLATIONS
INTEGRAL
FEET
SUPPORT
ROUGH
FLOOR
35mm
(1-3/8)
98mm
(3-7/8)
107 Lbs. (49 Kg.)
640 Lbs. (291 Kg.)
64 Gal. (243 L)
53 Gal. (201 L)
45 x 23 In. (1143 x 584mm)
63 x 32 In. (1600 x 813mm)
13 In. (330mm)
35 Lbs./Sq.Ft. (166 Kgs./Sq.m)
25.6
49.4
2.1 HPR, 15.6 AMPS, 120V.
THANK Y O U.. .
for selecting an American Standard bath. Your new
bath is shipped to you after careful inspection. The
whirlpool version is completely assembled with pump,
motor, and system piping. All you need to finish the
installation are your selected fittings and electrical
connections for a whirlpool.
To insure maximum performance and pleasure from
this product, please follow the instructions and
cautions.
List of Optional Components (not included):
• Safe-T-Heater 9075.120*
* see your American Standard Distributor
List of Required Components (not included):
• Drain 1583.470*
• Bath Filler*
* see your American Standard Distributor
List of Required Tools and Supplies:
Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard
Woodworking Tools
• Personal Safety
Equipment
• Caulking Gun
© AS America, Inc. 2009
All product names listed herein are trademarks
of AS America, Inc. unless otherwise noted.
Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 3 or 2 x 2
Stringers
• Drop Cloth
• 20 amp GFCI
Outlet
• Cement, Plaster,
Grout

Advertisement

loading

Summary of Contents for American Standard ELLISSE OVAL 2709

  • Page 1: Installation Instructions

    Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead (required for recess installations).
  • Page 2 FRAMING AND INSTALLATION THE VARIETY OF INSTALLATIONS POSSIBLE FOR THIS BATH MAY REQUIRE FRAMING PROCEDURES OTHER THAN THOSE SHOWN. LOCATE STUDS AS REQUIRED. INSURE ROUGH DIMENSIONS ARE PROPER, PLUMB AND SQUARE. FOR WHIRLPOOLS, PROVISION MUST BE MADE IN ALL INSTALLATIONS FOR AN ACCESS OPENING FOR SERVICING PUMP AND CONTROLS. THE FOLLOWING PROCEDURE MUST BE USED FOR ALL INSTALLATIONS: STRINGER OR PIER HEIGHT SHOULD BE AS INDICATED.
  • Page 3 ELECTRICAL INSTALLATION INSTRUCTIONS All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes. WARNING: When using electrical products, basic precautions should always be observed, including the following: DANGER: RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a ground-fault circuit interrupter.
  • Page 4 WI RE SE LECTI ON G UID E M ax im um d ist ance f r om Motor T he siz es sh own o n th i s fu se box t o m o t or Hi-Performance ch ar t ar e r e co mme nda ti on s Rating 100'...