Flushometer – Toilet Flush Valve - American Standard Selectronic Operating Manual

Table of Contents

Advertisement

From MENU 4.4
MENU 4.5
NOT USED
LF URINAL + PF
MENU 4.6
FLUSHOMETER
MENU 4.7
NOT USED
KITCHEN
TIP: The "Rinse" is the Flush Time (Flush Duration).
See Flush Valve Settings Chart
To MENU 4.7
DETEC. INTERVAL
= 3 Sec
Press up or down to adjust the
user detection activation time
RINSE START INT
= 7
Press up or down to adjust
how long to wait after the
user leaves to begin the flush
RINSE
= 7 s
Press up or down to
adjust Flush Time
Flushometer – Toilet Flush Valve
TIP: The "DETEC. INTERVAL" (Detection Interval) is how
long a user must be in the detection zone to arm the flush
valve. This eliminates false flushing due to people walking
past the urinals. Recommended setting is 5 sec.
TIP: The "RINSE START INT." (Rinse Start Interval) is
how long after the user leaves the detection zone before
the valve will flush. Recommended setting is 3 sec.
Align the programmer with the sensor
Auto. RINSE
and press to transmit the program, with
= OFF
the Auto Rinse OFF, to the sensor
Press up or down to turn
ON the Auto Rise feature
and adjust frequency
Auto. RINSE
TIP: The "Auto. RINSE'" (Sanitary Flush) allows the
= 72 h
flush valve to automatically flush, after a set time period
of non-use, to maintain the trap seal . This time period
can be set to activate from OFF to 72 hrs (of non-use) in
1 hr increments. You can set the duration of flush time
from 1 sec. to 240 sec. –never more than the fixture
can drain before overflowing! (Recommended
setting is OFF unless prolonged non-use is
Auto. RINSE
expected – then 2 s should maintain the trap seal).
= 55 s
Default Setting: 'Off'
Press up or down to adjust
the Auto Rinse run time
Align the programmer with the sensor
and press to transmit the program, with
the Auto Rinse ON, to the sensor
10