Summary of Contents for American Standard 605XRCT

  • Page 1 Selectronic Remote Control Operating Manual Software Version 1.6 M965370 REV. 1.6 (June 2019)
  • Page 2 Transmission Area Mini-SUB Port OPERATION: The remote programmer has 4 keys: “Enter” or validate “Cancel” “Scroll UP” “Scroll Down” The ‘Down’ Key is also used to turn “ON” the remote programmer. After not being used for 2 minutes, the programmer automatically turns itself off.
  • Page 3 Setting The Detection Distance ONLY DONE AFTER SELECTING ALL THE MODE SETTINGS When using the programmer, the sensor will begin blinking for approximately 5 seconds after the “ENTER” key is pressed and the display shows “TRANSMISSION OK”. While it is blinking move your finger to within 1 inch of the sensor (nearly covering it). When the light stops blinking and stays on steady, remove your finger and, with the palm of your hand facing the sensor, move your hand to the distance to be set.
  • Page 4 Start Cleaning Disinfection Press to turn on the programmer (Version VI.6 will display) Diagnostics Press to activate the menus TIP: Cleaning – Use this mode to disable the sensor for MENU 1 1 minute. This is sometimes used by the cleaning crew to keep CLEANING the faucet “off”...
  • Page 5 Parameter SENSOR 2018 URI. & WC Language From MENU 3 SENSOR 2018 FAUCET Backlight MENU 4 PARAMETER NEXTGEN From this menu, scroll down to the specific mode you want SENSOR MENU 5 to program: 2016 VERSION PARTIAL COUNT • Urinal Align the programmer NOTE: Not all features are with the sensor and press...
  • Page 6 Hand-Wash NOTE: This is the standard ʻinstant on / instant offʼ faucet mode. Setting the sensor to the Hand-Wash faucet mode: - Set the "Comfort Timeout" From MENU 4 - Set the "Safety Timeout" - Set "Auto-Rinse" frequency (if the frequency is set to 0, “auto-rinsing”...
  • Page 7 Metering -- Faucet Setting the sensor to the Metering faucet mode: (RUN TIME) COMF. TIMEOUT - Set the "Comfort Timeout" (run time) Press up or down to adjust = 15 Sec. From MENU 4.1 metering run time - Set "Auto-Rinse" frequency (if the frequency is set to 0, ‘auto-rinsing”...
  • Page 8 Metering with On/Off -- Faucet NOTE: This is actually uses the ‘Metering’ mode, but with the added feature of being able to start and stop the water flow before the metering time runs out. Setting the sensor to the Metering faucet mode: - Set the "Comfort Timeout"...
  • Page 9 Urinal -- Urinal Flush Valve TIP: The "DETEC. INTERVAL" (Detection Interval) is how long From MENU 4 a user must be in the detection zone to arm the flush valve. This eliminates false flushing due to people walking past the urinals. Recommended setting is 5 sec.
  • Page 10 Flushometer – Toilet Flush Valve TIP: The "DETEC. INTERVAL" (Detection Interval) is how long a user must be in the detection zone to arm the flush valve. This eliminates false flushing due to people walking past the urinals. From MENU 4 Recommended setting is 5 sec.
  • Page 11 Dual Flush – Toilet Flush Valve From MENU 4 TIP: The "Short Rinsing" is the is the flush time used when the user stays in the detection zone for less than 1 minute. – This should be the setting for the lowest of the 2 flush volumes listed for MENU 4.8 *SHORT RINSING this model flush valve.
  • Page 12 OFF - 72 hr (in 1 hour increments) OFF - 72 hr (in 1 hour increments) OFF - 72 hr (in 1 hour increments) OFF - 72 hr (in 1 hour increments) OFF - 72 hr (in 1 hour increments) OFF - 72 hr (in 1 hour increments) OFF - 72 hr...