NOTE: Dense smoke will override the SMART HUSH
sound a continuous alarm.
CAUTION: Before using the alarm SMART HUSH
the source of the smoke and be certain safe conditions exist.
8. BATTERY
BATTERY ACTIVATION AND DEACTIVATION
NOTE: One Lithium-Ion battery, permanently sealed inside the alarm, powers this
unit; no battery installation or replacement is necessary for the life of the alarm.
IMPORTANT: Constant exposure to high or low humidity may reduce battery life.
WARNING! DO NOT ATTEMPT TO OPEN THE ALARM
FOR ANY REASON!
Do not try to repair the smoke alarm yourself. No serviceable parts included.
Low battery: This alarm is equipped with a low battery monitor circuit which
will cause the alarm to produce a single "chirp" approximately every 60
seconds and blink the Red LED every 30 seconds, for a minimum of seven
(7) days should the battery become low.
Model P3010B will also issue a voice prompt stating "Low battery."
THE UNIT MUST BE DEACTIVATED (see "Deactivation of Alarm"
section) and replaced within 7 days of the first occurrence of the
"Low Battery Warning" to provide continuous alarm protection.

9. DEACTIVATION OF ALARM

WARNING!
• Deactivation of the alarm is permanent. Once the alarm has
been deactivated, it cannot be reactivated!
• Once deactivated, the alarm will NO LONGER DETECT SMOKE.
• Once the alarm is deactivated the battery will be depleted and
the alarm will no longer function.
• Once the alarm has been deactivated, it cannot be mounted
onto the mounting plate or reactivated.
WARNING! Failure to turn off alarm as instructed prior to disposal
may create potential for lithium battery related fire or hazard.
feature and
TM
TM
feature, identify
TO DEACTIVATE THE ALARM:
Remove the alarm from the mounting plate
by rotating it in the direction indicated by
the arrows on the cover of the alarm.
On back side of alarm, locate the
area on product label.
Break through label with a screw driver.
Turn the screw to the "OFF" location.
This will deactivate the alarm, stop the
low battery "chirp" and render the alarm
safe for disposal by draining the battery.

10. CLEANING YOUR ALARM

YOUR ALARM SHOULD BE CLEANED AT LEAST ONCE A YEAR
You can clean the interior of your alarm (sensing chamber) by using compressed
air or a vacuum cleaner hose and blowing or vacuuming through the openings
around the perimeter of the alarm. The outside of the alarm can be wiped with
a damp cloth. Use only water to dampen the cloth, use of detergents or clean-
ers could damage the alarm.
After cleaning, test your alarm by using the test button. If cleaning does
not restore the alarm to normal operation, the alarm should be replaced.
• Never use detergent or other solvents to clean the unit.
• Avoid spraying air freshener, hair spray, or other aerosols near the
Smoke Alarm.
• Do not paint the unit. Paint will seal the vents and interfere with the
sensor's ability to detect smoke.