Remedial Action In The Event Of Faults - Electrolux DAGL55 Operating Insructions

Electrolux extractor hood
Table of Contents

Advertisement

12 electrolux

Remedial action in the event of faults

Check whether you can correct any minor faults on the appliance yourself, by means of the
following instructions. If this information is of no help in your specific case, please contact
After Sales.
Fault
• The extractor hood will
not work at all.
• The fan motor will not
run.
• No light
• The appliance does not
„extract" well.
• Smoke when hood is in
operation.
• Formation of grease
droplets
• Filter becomes clogged
with grease
• Hood becomes extre-
mely dirty
• Grease and deposits on
furnishings
• Excessive contamination
behind the filters and in
the exhaust ducts.
• Condensation on the
extending hood.
• Inadequate extraction
power in exhaust
mode.
Caution! Damaged appliances must not be used. Switch off circuit breakers or un-
screw fuses in the event of a fault or malfunction.
Caution! Do not attempt to mend the appliance. Any work incorrectly carried out may
lead to material damage and personal injury.
If you are not able to correct any faults or malfunctions by means of these tips, please con-
tact After Sales.
Cause
• No mains power supply.
• Extending hood not pulled
out.
• Bulb blown.
• Very airtight doors and win-
dows, resulting in negative
pressure.
• Negative pressure
• Hood switched on too late.
• Boiling water without
switching on the extractor
hood.
• Operation at a too low fan
speed.
• There is excessively low ne-
gative pressure in the room.
• Excessively high air speed.
• There is excessively low
negative pressure in the
room.
High air resistance as a result
of:
• exhaust duct diameter too
small.
• exhaust duct badly routed.
Solution
• Check whether the fuse/
circuit breaker is OK.
• Check whether the mains
cable is correctly plugged
in.
• Pull out the extending
hood.
• Replace bulb.
• Open doors and windows,
but not in the immediate
vicinity of the cooker. En-
sure that there is adequate
ventilation.
• Install a valve for exter-
nal ventilation, or open a
window.
• Switch on the extractor
hood in good time.
• Select a higher speed.
• Enable ventilation, open
ventilation valve or doors/
windows.
• Run the extractor hood at
a lower speed.
• Enable ventilation.
• Use 150 mm diameter
exhaust duct.
• Re-route exhaust duct
more effectively.