AEG 61502G Operating Instructions Manual page 13

Gas hob
Hide thumbs Also See for 61502G:
Table of Contents

Advertisement

TYPE OF GAS
NOMINAL THERMAL
POWER
NATURAL GAS
20 mbar
NOMINAL FLOW
VALUE =
RATE
37.78 MJ/m
3
NOZZLE
Ws - 50.7 MJ/ m
3
NOMINAL THERMAL
LPG GAS
POWER
28-30/37 mbar
NOMINAL FLOW
VALUE =
RATE
49.92 MJ/Kg
NOZZLE
Burner
Auxiliary
Semi-rapid
Rapid
Aeration adjustment none
BURNER
POSITION
kW
m
3
/h
REFERENCE
1/100 mm
kW
g/h
REFERENCE
1/100 mm
Dia. Tap By-pass
1/100 mm
28
32
40
RAPID
SEMI-RAPID
(large)
(medium)
M A X
MIN
M A X
3.0
0.65
2.0
0.286
0.057
0.190
119
Adjust.
9 6
2.8
0.65
2.0
202
43.5
144
8 6
4 0
7 1
AUXILIARY
(small)
MIN
M A X
MIN
0.45
1.0
0.33
0.038
0.095
0.028
Adjust.
7 0
Adjust.
0.45
1.0
0.33
2 9
7 2
21,5
3 2
5 0
2 8
1 3

Advertisement

Table of Contents
loading

Table of Contents