11.
Fuse (Fig.1. 3)
The modelling and flash circuitry is protected by a single 5 amp (F) 20mm
fuse mounted on the rear panel. Never replace the fuse with one of a different
rating. As the fuse may blow when the modelling lamp fails always check the
fuse when replacing bulb. A spare fuse is supplied in the fuse holder. Always
switch OFF the Esprit 250 before changing the bulb or fuse.
12.

Fitting / Removing A Reflector

A range of reflectors is available for the Esprit 250. To fit, slide the neck of
the reflector over the front of the unit. Align the three pegs on the reflector
with the three slots in the retaining ring. Press down and turn clockwise to
lock.
To remove reflector, press Latch Knob (Fig.2. 1) turn the reflector fully anti-
clockwise and withdraw.
If an umbrella is to be used a 'Spill Kill' (BW-1885) should be fitted and the
umbrella inserted through the hole in the mounting bracket on the Spill Kill
and locked into position with the knurled screw.
Note: Take care when fitting / removing reflectors not to damage the
flashtube assembly. The flashtube is very delicate, avoid unnecessary handling
of the glass tube. Always switch off and disconnect from mains supply before
fitting / changing the flashtube assembly.
Do not touch the flashtube assembly for thirty minutes after
disconnecting from supply.
13.

Replacement Of Flashtube

Ensure that the unit is switched off and disconnected from the mains supply
and then wait thirty minutes before touching / removing flashtube. Remove the
protective cap and unwind the twisted Trigger wire from the flashtube support.
Gently pull flashtube assembly out of the unit. To replace the flashtube,
holding the flashtube as shown in Fig.3 and taking care to support both legs of
the tube,gently but firmly, push the flashtube into position. Wind the Trigger
wire around the flashtube support.
14.
Operation
Mount the Esprit 250 on selected support system. The mounting bush on the
'L' bracket allows for two possible ways of mounting to the stand / support
(Fig.4). Method B may be found useful if the light is required to point down.
Fit the reflector and connect to supply.
Plug in the sync cord and connect to camera shutter at 'x' synchronisation.
Alternatively, plug in Infra Red Receiver or Omnicell. Switch ON and select
modelling lamp ON or OFF and flash power required. When the unit is ready

Warning High Voltage