Water Connection; Water Inlet Hose - AEG Favorit 88025 VI User Manual

Aeg dishwasher favorit 88025 vi
Table of Contents

Advertisement

We recommend that you make a custom made
kick-panel that aligns your kitchen cabinets.
• A notched continuous panel is necessary to pre-
vent door swing interference and to keep kick-
panel alignment with adjacent units.
• Cut a notch in the kick-panel sufficient to let
the door swing freely under the appliance.
• Make a check for interference. Open and close
the door slowly. If the door touches the kick-
panel, trim to prevent interference.
• Attach the kick-panel to adjacent cabinets so
that if service is necessary you can remove it.

Water connection

Water inlet hose

Connect the appliance to a cold water supply.
Connect the inlet hose to a water tap with an external BSP thread spout of 3/4".
CAUTION!
Always use new hoses when you connect the appliance to the water mains. Old hoses must
not be used. The water inlet hose must be examined at an interval of twelve months for
deterioration and replaced if necessary.
The water pressure must be in the limits (refer to 'Technical data'). Make sure that the local
water authority gives you the average mains pressure in your area.
Make sure that there are no kinks in the water inlet hose and that the water inlet hose is
not squashed or entangled.
Fit the hose nut correctly to prevent water leaks.
CAUTION!
Do not connect the appliance to new pipes or pipes that have been not used for a long
time. Let the water run for some minutes, then connect the inlet hose.
The water inlet hose is double-walled and has an inner mains cable and a safety valve. The
water inlet hose is under pressure only while the water is running. If there is a leak in the
water inlet hose, , the safety valve interrupts the running water.
Be careful when you install the water inlet hose.
WARNING!
• The mains cable is in the double-walled inlet hose. Do not immerse the water inlet hose
or the safety valve in water.
• Do not attempt to shorten the inlet hose.
• If the water inlet hose or the safety valve is damaged, immediately turn off the power
and remove the mains plug from the mains socket.
• Only a qualified Service Engineer can replace the water inlet hose with safety valve.