The iQ Drive Thermostat features additional fi ne-tuning options that can increase comfort, save energy,
and maximize the performance of the heating and cooling system. These settings are optional and do
not require modifi cation for the heating/cooling system to operate. However, some of these settings may
require the consultation of an installer for determining which settings will achieve peak performance.
This thermostat contains customizable energy-saving schedules (also called events) that can adjust the
heating/cooling system 2 or 4 times a day on individual days, every day, just weekdays, just weekends,
an entire week or a combination of days. Residential systems can be setup for a 2 event or 4 event
per day schedule. Companies can set their schedule to 2 events per day using the business option. By
default, this thermostat is factory set to a 4 Schedule Events/Day. If the nonprogrammable option or
other event schedule is desired, then this setting must be changed before programming the thermostat.
NOTE: Full programmable operation may be resumed by performing steps 1 - 9 below and selecting a
programmable option in the program schedule usage menu.

Programmable Options

4 Schedule Events/Day
• WAKE: The temperature setting in the morning
when everyone wakes up.
• LEAVE: The temperature setting for the time
away from home and energy savings are
wanted.
• RETURN: The temperature setting in the
evening when everyone returns home.
• SLEEP: The temperature setting at night when
everyone is asleep.
2 Schedule Events/Day
• DAY: The temperature setting during daylight
hours.
• NIGHT: The temperature setting during night
time hours.
2 Events/D Business
• ACTIVE: The temperature setting during
business hours.
• IDLE: The temperature setting when business
is closed.

ADVANCED THERMOSTAT SETTINGS

Program Schedule Usage

Nonprogrammable Option

The nonprogrammable option disables the
usage of all programming schedules, Smart
Recovery, and temperature holds. It requires no
programming and is as basic as operating an old
manual style rotary thermostat.
To use this option, perform steps 1 - 9 below
and select NONPROGRAMMABLE in step 8. To
activate an air conditioner, furnace, or heat pump,
place the thermostat in an operating mode as
described on page 6. Adjust the temperature by
simply pressing the
on the Main Screen (or by accessing the TEMP
menu on the Main Screen). When the desired
temperature setting is displayed, press the
button to save the setting.
1. Select MENU on the Main Screen using the
or
button.
2. Press the
button.
3. Select SETTINGS using the
4. Press the
button.
5. Select OPTIONS using
the
or
button.
6. Press the
button.
NOTE: The OPTIONS
menu will appear in the
display with an event
beneath EVENTS PER
DAY already selected.
7. Press the
button.
8. Change the event using the
9. Press the
button to save the setting.
or
buttons anywhere
or
button.
or
buttons.
11