Cognos Transformer does not allow dimension views that use Summarize or
Cloak for time dimensions that specify a time-state rollup for one or more
measures.
Procedure
To resolve the problem, do one of the following:
v Eliminate the summarized or cloaked view from the time dimension.
v Eliminate the time-state rollup for the measure.

TR2723

A gap has been detected between partition n and n+1. No gaps in partition
numbers are permitted.
You have tried to specify partition level numbers for a model, and you have
inadvertently missed a number. You cannot leave a gap in the series of numbers
assigned to partition levels.
For example, suppose your dimension contains four levels: 1 through 4. You
cannot assign partition level 1 to the highest-level categories and partition level 3
to their immediate descendants.
Procedure
In the above example, you must assign partition level 2 to categories at the level
between levels 1 and 3.The same constraint applies when you specify partition
level numbers across different dimensions. You must avoid setting level 1 for
categories in one dimension and level 3 for categories in another dimension,
without setting level 2 somewhere else.

TR2724

Partition n is defined in dimensions dimension_name1 and dimension_name2. A
partition number cannot be assigned in more than one dimension.
You have tried to specify partition level numbers for a model, and you have
inadvertently assigned the same number to categories in different dimensions.
Procedure
To resolve the problem, change the partition numbers currently specified for the
categories in your model to avoid duplicate partition numbers in different
dimensions.

TR2725

Category category_name1 is a descendant of category category_name2 and shares
the same partition number in dimension dimension_name. A partition number can
only occur once in a category path of a dimension.
You have tried to specify partition level numbers for a model, and you have
inadvertently used the same level number more than once in the path from the
root to the leaf category of a dimension.