4. PERFORMANCE SPECOFOCATIONS
Input voltage
Frequency
Input
Fuse rating
Rush current
Output voltage
Output current
Output
Ripple noise
Holding time
Protection against
overcurrent *2
Protection
function
Protection against
overvoltage *3
Output indication
Others
[Output derating]
100
80
60
40
20
0
0
10
Ambient temperature (°C)
*1 The available output current varies depending on the ambient operating temperature. Use the FX
20PSU in the available range in accordance with the output derating graph shown above.
*2 If the output current flows beyond the specified value, the overcurrent protection circuit is actuated
and the output voltage drops.
When the overcurrent status or the short-circuit status returns to acceptable levels, the output voltage
automatically recovers.
*3 If the voltage beyond the specified value is generated by an internal failure, etc., the output is shut
down so that high voltage is not output. When the voltage comes from a load circuit connected to an
output terminal or when overvoltage is input from the outside, the overvoltage protection circuit may
be actuated.
When the overvoltage protection circuit is actuated, the output is shut down and does not automati-
cally recover. Ask for inspection and repair after such an occurance.
85 to 264V AC
50/60Hz
3.15A (built in)
60A/200V AC maximum
24V DC ± 10%
2A (maximum), 0.2A (minimum)
(Derating is performed if ambient temperature exceeds 40 °C.)*1
500mVp-p or less
10ms/100V AC
Actuated when current becomes 110 - 160% or more, voltage drop
occurs automatic recovery
Actuated when voltage becomes 110 - 140% or more, output shuts-
down, no automatic recovery (diode clamp)
Green LED(POWER) is lit while voltage is output.
Serial/parallel operation with other power supply units is not allowed.
(See Section 6.3)
20
30
40
50 55
-
2N