Technical Data; Safety Device - DeLonghi CH SILVE R Instructions Manual

Catalytic heater

Advertisement

573244 GB
30-01-2001 09:42

Technical Data

Type
Category
see rating label
This appliance is designed to operate with Butane, propane or mix LPG at nominal pressure:
28 ÷ 30 mbar. For a correct gas combustion the required air quantity is 6 m
-
ALWAYS use heater in accordance with instructions. Read the instructions book carefully
and keep it in a safe place.
-
This appliance requires a rubber tube and a pressure regulator in accordance with the
law in force. If not supplied check with your gas supplier.
-
Use ONLY in a well ventilated area.
-
This appliance MUST NOT be used in basements, high rise flats, bathrooms or
bedrooms and in rooms having volume less than 18,5m
-
This appliance emits the combustion residues in the room in which is used.
-
DO NOT place clothes or other materials on the heater, as apart from the danger of fire
their presence could affect the efficient working of the appliance (fig. 1).
-
DO NOT move heater from room to room when it is lit (fig. 2).
-
DO NOT position heater alongside a wall or near curtains or arm-chairs etc. (fig. 3 - 4).
-
ALWAYS face heater towards centre of room. Special care should be taken if the heater
is on a surface where it can move or twist on its wheels or castors if knocked by a child
or dog, etc.
-
Minimum Clearance : 200 mm from sides,1500 mm from front.
-
Be sure installation is complying to local standard.
-
Set the appliance to run on maximum for at least 15 minutes the first time it is used, in
order to get rid of the "new" smell and a small amount of smoke coming from protective
substances applied to the components. Air the room while this procedure takes place.

Safety device

The heater you have purchased is fitted with safety devices which come on in the event of
malfunctioning while the appliance is in use. If the pilot light (placed opposite the burner)
accidentally goes out, or if the room is not sufficiently ventilated, the safety device will block
the gas flow, causing the heater to go off.
Pagina 3
CATALYTIC HEATER
Maximum
Medium
Input
Input
KW
g/h
KW
g/h
3.0
218
2.35
170
WARNINGS
Low
Gas pressure
Input
KW
g/h
1.85
134
28÷30 mbar
/h.
3
(37 m
in living rooms).
3