Download Print this page

Installation - DeLonghi WH 45 Nat Operating Instructions

Infrared gas heater type of gas: natural

Advertisement

573291
29-07-2002
10:00
TECHNICAL SPECIFICATIONS
The manufacturer reserves the right to make any modifications it feels appropriate at any time.
MODEL
WH 45
Kcla
Nat
4500
3100
1650

INSTALLATION

Mounting to the wall
-
remove the two self-threading screws from the bottom two corners of the front part (see
Figure 1);
-
remove the front part slowly, by lifting it from below and pushing it upwards, and then
detaching it from the rear part;
-
make four 6mm holes in the wall, following the indications shown in Figure 2;
-
place the plastic plugs supplied in the holes;
-
fasten the rear part to the wall using the 4 screws supplied;
-
replace the front part, performing the same operations described previously in reverse
order.
FITTING THE FEET/WHEELS
-
fasten the wheels and the feet to the holes shown in Figure 2, using the screws supplied.
IMPORTANT
The heater only works on natural gas at an inlet pressure of 18 mbar.
The adjustment and maintenance operations must only be performed by specialist personnel.
WARNING
The residues of combustion from the heater are discharged in the room, therefore sufficient ven-
tilation must be ensured.
For correct ventilation, the room that the appliance is used in must have an opening of at least
100 cm
. If necessary, this opening can be created by increasing the distance between the door
2
and the floor.
ON-OFF
Open the mains supply line cock.
Starting from position "0", fully press the adjustment knob and turn it anticlockwise, to position
"1". In this position, the pilot flame must ignite (if not, continue to press the knob for around 10
seconds so as to release any air in the pipes, and repeat the above operation).
2
Pagina 2
MODEL
Hourly
consumption
Kcla
m
/h
3
17865
0,560
21183
0,387
6485
0,207
Adjustment
Volume
heated
knob pos.
m
3
3
150
2
103
1
55

Advertisement

loading