Flame Color And Behavior - Lennox Hearth Products Vintage VIN Installation And Operation Manual

Elite series direct-vent
Table of Contents

Advertisement

TO TURN OFF GAS TO APPLIANCE
1. Turn off the "ON/OFF" rocker switch and/or thermostat (if in-
stalled) to its lowest setting.
2. Turn off electric power to the appliance if service is to be
performed.
3. Push in gas control knob slightly and turn clockwise
to "OFF." Do not force.
This appliance needs fresh air for safe operation and must be
installed so there are provisions for adequate combustion and
ventilation air.
SHUTDOWN PROCEDURE
To turn off the burner, turn the rocker switch to "OFF" or adjust
the thermostat (if installed) to a setting below room temperature.
The pilot will remain lit for future burner ignition. For complete
shutdown, see "TO TURN OFF GAS TO APPLIANCE" above.
• Improper installation, adjustment, alteration,
service or maintenance can cause injury or
property damage. For assistance or additional
information, consult a qualified installer, service
agency or your gas supplier.
• Operation of this appliance when not connected
to a properly installed and maintained venting
system can result in carbon monoxide (CO)
poisoning and possible death.
• Carbon monoxide poisoning – early signs of
carbon monoxide poisoning resemble the flu
with headaches, dizziness, or nausea. If you
have these signs, get fresh air at once! Have
the heater inspected by a qualified service
technician. Some people are more affected by
carbon monoxide than others. These include
pregnant women, people with heart or lung
disease or anemia, those under the influence
of alcohol and those at high altitudes.
Flame Height Control Knob
- LO / HI +
(Commande De
Taille De Flamme)
Figure 29
20
WARNINGS
Igniter / Allumeur
PILOT
Gas Control Knob
(pilot/on/off )
Bouton de contrôle
(veilleuse/ouverte/fermée)
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Flame Height Control
Knob (HI/LO)
Figure 30
SIT Millivolt Gas Valve

Flame Color and Behavior

Your Vintage™ gas stove is designed for maximum heating efficiency.
Therefore, upon lighting of the main burner the flames will be semi-
transparent or "bluish." After 10-20 minutes of operation the logs will
heat up and the flames will become a yellow/orange color.
Adjusting the stove to cause the flames to turn orange sooner may result
in poor combustion, sooting and a hazardous situation. See Figure 31
showing proper flame appearance.
When testing for proper operation - If an optional thermostat is installed
adjust it to its highest temperature setting. Visually determine that main
burner gas is burning properly: i.e., no floating, lifting or flashback.
Adjust the primary air shutter(s) as required. Check for proper main
burner operation at both high and low flame.
Burner Flame Appearance
Soot above
Soot at
Flame Tip
Flame Tip
Dark Orange
Flame
Ports on Pan
Burner Assembly
No Blue Flame
Center
IMPROPERLY
BURNING FLAME
Figure 31
Pilot Flame Appearance
Figure 32
Gas Control Knob
(Pilot / On / Off)
No Soot at
Flame Tip
Semi-Transparent
Yellow Flame
Blue Flame
Center
PROPERLY
BURNING FLAME