ELECTRICAL CONNECTIONS
IF COOKTOP IS USED IN A NEW BRANCH CIRCUIT INSTALLATION (1996 NEC), MOBILE
HOME, RECREATIONAL VEHICLE, OR WHERE LOCAL CODES DO NOT PERMIT GROUNDING
TO THE NEUTRAL (WHITE) WIRE
Observe all governing codes and local
ordinances.
Disconnect the power supply.
At the circuit breaker box, fuse box or junction
box, connect appliance and power supply cable
wires as shown.
WARNING
If connecting to a 4-wire power supply cable
electrical system, the appliance frame
connected ground wire MUST NOT be
connected to the neutral wire of the 4-wire
electrical system.

COOKTOP INSTALLATION

Visually inspect the cooktop for damage.
Make sure all cooktop screws are tight
(see below for locations).
Screws
(cont.)
4-WIRE GROUNDED JUNCTION BOX
Cable from power supply
Ground
Wire
Red
wires
Green wire (ground)
Cable from cooktop
Carefully lower the cooktop into the counter- top
cutout, making sure not to trap any wires.
NOTE: Do not use caulking compound. The
cooktop must be removable, should service be
required.
White wire
(no connection)
Black
wires
Junction box
UL-listed conduit
connector