  • Page 6 4“ MAX...
  • Page 7: Lighting Instructions

    LIGHTING INSTRUCTIONS AND SHUT-OFF PROCEDURES MANUALLY LIGHTED PILOTS (MILLIVOLT SYSTEM) A. This appliance has a pilot that must be lighted by *If you cannot reach your gas supplier, call the hand. When lighting the pilot, follow these fire department. instructions exactly. C.
  • Page 8: What To Do If You Smell Gas

    OPERATING INSTRUCTIONS AND SHUT-OFF PROCEDURES AUTOMATICALLY LIGHTED PILOTS (ELECTRONIC IGNITION SYSTEMS) A. This appliance is equipped with an ignition *If you cannot reach your gas supplier, call the device which automatically lights the pilot. Do fire department. not try to light the pilot by hand. C.
  • Page 12 foot Minimum foot Minimum foot Minimum foot Minimum foot foot Minimum Minimum Forced Air Inlet U.S. Installation Only...
  • Page 15 10' OR LESS VENT CAP 2' MIN 2' MIN 5' MIN VENT PIPE DRAFT HOOD HEATER The gas pressure regulator is preset and sealed at 4" WC for natural gas, and 11" WC for propane. Between the gas valve and the burners is a 1/8" pipe plug. The pressure at this point, taken with a manometer, should be about 3.7"...
  • Page 16 Gas Pressure Gas Pressure Test at Heater Test at Gas Valve Gas Pressure Adjustment...
  • Page 17 Inlet/Outlet Header Flange Gasket Header Flange Pipe Unitherm Governor Outlet Inlet...
  • Page 18 From Heater To Heater Auxiliary Bypass Valve (do not use gate valve) Drain Pipe Drain Pipe Heater Outlet Heater Outlet...
  • Page 19 240V ATMOSPHERIC HEATER BLACK BLACK SUPPLY SIDE HEATER 4 WIRES GREEN GREEN Robertshaw Intermittent Ignition Device WHITE Honeywell Intermittent Ignition Device 120V ATMOSPHERIC HEATER 120V LOW NOx HEATER BLACK BLACK SUPPLY RETURN SIDE NEUTRAL WHITE WHITE HEATER 4 WIRES WIRING DIAGRAM KEY GROUND PINK CONNECTOR BLUE CONNECTOR GREEN...
  • Page 22: High Limits

    Typical Comfortable Pool Typical Temperature Comfortable Range Temperature Range Knobstop Ring Set Screw Drain Valve HIGH LIMITS (Located in the Inlet/Outlet header) Pressure Switch Burner & Pilot Thermal Fuse Solid State Thermostat & Ignition Control Gas Valve...
  • Page 23 Adjustment Knob Heat Exchanger Height 5' Max. 5' Max. Pool or Spa Heat Exchanger Height Fig. # 8152.0s...
  • Page 24 Opening Orifice...
  • Page 25 Immersion Well...
  • Page 26 U.G. U.G. Retainer Shield Spring Outlet Inlet Inlet/Outlet Header...
  • Page 27 These instructions are primarily intended for use by qualified personnel specifically trained and experienced in the installation of this type of heating equipment and related system components. Installation and service personnel may be required by some states to be licensed. Persons not qualified shall not attempt to install this equipment nor attempt repairs according to these instructions.
  • Page 28 ... . replace. U.G. not functioning...... Replace if no movement when heated. Leaking at well Overacid........Replace well and maintain water chemistry properly. Leaking at heat exchanger Overacid........Replace heat exchanger and maintain chemistry properly.
  • Page 29: High Voltage

    WARNING HIGH VOLTAGE ELECTRICAL - IID For qualified Technicians ONLY NOTE: Some heaters may be equipped with Intermittent Pilot System an ignition module that shuts off pilot gas if TROUBLESHOOTING HONEYWELL S8600 pilot fails to light. To reset, interrupt power to heater.
  • Page 30 ELECTRICAL - IID, SOLID STATE THERMOSTAT If the pool/spa/hot tub water is too cold, troubleshoot the system as follows: Check voltage at 24 V terminals. VOLTAGE BETWEEN 21.5-28.5 V. VOLTAGE OUTSIDE RANGE 21.5-28.5 V. Set control to max. temperature. After 2-3 Check transformer, 120 V supply, correct as cycles, check water temperature.
  • Page 32 10-H 12-H 13-H 14-H 11-H Fig # 240654 11-P HONEYWELL MILLIVOLT PILOT HONEYWELL IID PILOT 12-P 13-P 14-P 15-P 14-P Fig # 8133 Fig # 8132...
  • Page 33 CALL PREMIUM DESCRIPTION BRONZE BURNER TRAY Burner Tray w/Burners (Sea Level)* 004688F Burner 301210/4 Burner Orifice Nat. #52 (Sea Level)* 350081F/4 Burner Orifice Pro. #62 (Sea Level)* 350086F/4 CONTROLS High Limit 135 F 600889B High Limit 140 F 600890B Thermostat Control MV (Mechanical) 003346F Thermostat Control MV (Solid State) 005391F...
  • Page 34 CALL PREMIUM DESCRIPTION BRONZE PILOT Pilot Nat. MV 600525B Pilot Pro. MV 600575B Pilot Nat. IID 002003F Pilot Pro. IID 002003F Pilot Orifice Nat. MV 003901F Pilot Orifice Pro. MV 003902F Pilot Orifice Nat. IID 003903F Pilot Orifice Pro. IID 004308F Pilot Generator MV 600019B...