Message
Toner not recognized
Toner empty
Invalid Dept.Code
Memory is full
Clear paper output tray:
PRESS START KEY.
Meaning
The toner cartridge is not
installed correctly.
A toner cartridge not recom-
mended by TOSHIBA is
being used.
The toner in the toner car-
tridge has run out.
The department code
entered in the department
code entering screen is not
correct.
The built-in memory of the
equipment has become full.
Approx. 250 sheets of paper
have continuously exited and
the equipment stops copy-
ing to prevent the copied
paper from overflowing from
the tray.
Countermeasure
Install the toner cartridge correctly.
If you are using a toner cartridge other
than the one we recommend, the equip-
ment may not be able to detect whether it
is installed or not.
P.14 "Recommended toner cartridges"
Replace the toner cartridge with a new
one.
P.192 "Replacing Toner Cartridge"
Enter the correct department code. If you
do not know the department code, contact
your administrator.
Select "Print" on the LCD screen to copy
the data scanned so far. Select "Cancel
job" to delete all the data scanned so far.
Remove the paper from the receiving tray,
and then press the [START] button. Copy-
ing resumes.
Press the [CLEAR/STOP] button to end
the copy job. "Memory clear?" appears on
the LCD screen. Select "YES", and then
press the [START] or [ENTER] button.
When This Message Appears