• 12 V DC power supply terminal
q Loosen the screw of the power cable plug (accesso-
ry).
w Connect the output cable to the power cable plug.
Strip 3 mm to 7 mm {1/8 inches to 9/32 inches} from
the end of the wire, and twist the stripped part of the
wire sufficiently to avoid short circuit.
Specification of cable (wire): 16 AWG - 24 AWG,
* Check whether the stripped part of the wire is not
exposed and is securely connected.
e Tighten the screw of the power cable plug.
Recommended tightening torque: 0.339 N·m {0.25 lbf·ft}
r Connect the power cable plug to the 12 V DC power
supply terminal on the rear of the camera.
* FOR UL LISTED MODEL(S), ONLY CONNECT 12 V DC
CLASS 2 POWER SUPPLY (UL 1310/CSA 223) or
LIMITED POWER SOURCE (IEC/EN/UL/CSA 60950-1).
Power cable plug
(accessory)
IMPORTANT:
• The 12 V DC power supply shall be insulated from the
commercial AC power.
• Be sure to use the power cable plug provided with
this product.
• Be sure to fully insert the power cable plug into the
12 V DC power supply terminal. Otherwise, it may
damage the camera or cause malfunction.
• Be sure to use an AC adaptor compliant with the
Specifications regarding power source and power
consumption (☞ page 31).
22
Single core, twisted
Strip range
Approx. 3 mm - 7 mm
{1/8 inches - 9/32 inches}
+
Step 10
After completing the cable connections, attach the upper
and lower parts of the decorative cover (accessory).
q Match the "❘" position of the decorative cover to the
arrow of the unit, and then slightly push up the deco-
rative cover while holding the lower part of the deco-
rative cover.
q
w Push the decorative cover up until it is approx. 10 mm
{13/32 inches} from the ceiling, and then turn the
decorative cover by approx. 16 ° in the direction of
the arrow (clockwise) as illustrated.
e
w
(Approx. 16 °)
e After completing w, push up the decorative cover to
the ceiling until it covers all of the fixed section of the
unit.
Arrow
" ❘ " position
Decorative cover -
lower part (accessory)
Approx. 10 mm
{13/32 inches}