Specifications; Replacement Parts; Service Hints; Technical Service - Desa VMH10TPB Operation And Installation Manual

Unvented (vent-free) gas compact classic hearth fireplace
Table of Contents

Advertisement

SPECIFICATIONS

Thermostat Models:
VMH10TPB, EFS10TP VMH10TNB, EFS10TN VMH26PRA, EFS26PR,
Btu/Hr
10,000
Type Gas
Propane/LP Gas Only
Ignition
Piezo
Manifold Pressure
8.5" W.C.
Inlet Gas Pressure
(in. of water)
Maximum
14"
Minimum*
11"
Dimensions, inches (HxWxD)
7
Fireplace
25
/
8
(including hood
and screws)
5
Carton
32
/
8
Weight, pounds
Fireplace
44
1
/
2
Shipping
48 lbs.
* For purpose of input adjustment

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your
warranty coverage for parts replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers of this product. If they can't supply
original replacement part(s), call DESA Heating Products' Techni-
cal Service Department at 1-866-672-6040.
When calling DESA Heating Products, have ready
• your name
• your address
• model and serial numbers of your fireplace
• how fireplace was malfunctioning
• type of gas used (propane/LP or natural gas)
• purchase date
Usually, we will ask you to return the part to the factory.
PARTS NOT UNDER WARRANTY
Contact authorized dealers of this product. If they can't supply original
replacement part(s), call DESA Heating Products at 1-866-672-6040
for referral information.
When calling DESA Heating Products, have ready
• model number of your fireplace
• the replacement part number
For more information, visit www.desatech.com
For more information, visit www.desatech.com
107032-01J
Thermostat Models:
10,000
Natural Gas Only
Piezo
3" W.C.
10.5"
5"
13
3
7
x 26
/
x 9
/
25
/
16
8
8
13
5
5
x 27
/
x 11
/
32
/
16
8
8
lbs.
44
1
/
2
48 lbs.
Remote-Ready Models:
FMH26PR
14,000/26,000
Propane/LP Gas Only
Piezo
8" W.C.
14"
11"
13
3
7
x 26
/
x 9
/
25
/
16
8
8
13
5
5
x 27
/
x 11
/
32
/
16
8
8
lbs.
44
1
/
2
48 lbs.

SERVICE HINTS

When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• fireplace will not produce specified heat
• for propane/LP units, propane/LP gas supply may be low
You may feel your gas pressure is too low. If so, contact your local
natural or propane/LP gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, operation, or
troubleshooting. If so, contact DESA Heating Products' Technical
Service Department at 1-866-672-6040. When calling, please have
your model and serial numbers of your heater ready.
You can also visit DESA Heating Products' technical services web
site at www.desatech.com.
SPECIFICATIONS
REPLACEMENT PARTS
SERVICE HINTS
TECHNICAL SERVICE
Remote-Ready Models:
VMH26NRA, EFS26NR,
FMH26NR
14,000/26,000
Natural Gas Only
Piezo
3.5" W.C.
10.5"
5"
13
3
x 26
/
x 9
/
25
16
8
13
5
x 27
/
x 11
/
32
16
8
lbs.
44
48 lbs.
33
33
7
13
3
/
x 26
/
x 9
/
8
16
8
5
13
5
/
x 27
/
x 11
/
8
16
8
1
/
lbs.
2

Advertisement