Rheem RTG-53X Installation Instructions page 2

Tankless water heater recess box

Advertisement

Recess Box Location
guidelines below or in the Use and Care Manual provided with the water heater for choosing a suitable location.
X AIR SUPPLY INLET
V VENT TERMINAL
Water Heater Exhaust Terminal Location
The following information should be used for determining the proper location of
the vent terminal for outdoor tankless water heaters.
A= Clearance above grade, ve-
randa, porch, deck or balcony.
B= Clearance to window or door
that may be opened.
C= Clearance to permanently
closed window.
D= Vertical Clearance to venti-
lated soffit located above the
terminal within a horizontal
distance of 2 feet (61 cm)
from the center line of the
terminal.
E= Clearance to unventilated
soffit.
F= Clearance to outside corner.
G= Clearance to corner.
H = Clearance to each side of cen-
ter line extended meter/regu-
lator assembly.
I = Clearance to service regulator
vent outlet.
J = Clearance to nonmechanical
air supply inlet to building or
the combustion air inlet to any
other appliance.
K = Clearance to mechanical air
supply inlet.
L = Clearance above paved
sidewalk or paved driveway
located on public property.
M = Clearance under veranda,
porch, deck or balcony.
In accordance with current CAN/CGA-B149 Installation Code
1
In accordance with current ANSI Z223.1/NFPA National Fuel Gas Code.
2
* If clearances are not specified, then follow local installation codes and the requirement of the gas supplier.
** For condensing appliances: The vent for this appliance shall not terminate over public walkways, near soffit
vents, crawl space vents, or other areas where condensate or vapor could create a nuisance, hazard or cause
property damage, or where condensate or vapor could cause damage or could be detrimental to the operation
of regulators, relief valves or other equipment.
- This water heater recess box is intended for an outdoor location only. Follow the
AREA WHERE TERMINAL IS NOT PERMITTED
Canadian Installations
1
Indoor and Outdoor
12 inches (30 cm) above antici-
pated snow level.
6 inches (15 cm) for appliances ≤
10,000 Btuh (3 kW), 12 inches (30
cm) for appliances > 10,000 Btuh
(3kW) and ≤100,000 Btuh (30kW),
36 inches (91 cm) for appliances >
100,000 Btuh (30kW).
*
*
*
*
*
3 feet (91 cm) within a height 15
feet (4.57 m) above the meter/regu-
lator assembly.
3 feet (91 cm)
6 inches (15 cm) for appliances
≤10,000 Btuh (3 kW), 12 inches
(30 cm) for appliances > 10,000
Btuh (3kW) and ≤ 100,000 Btuh
(30kW), 36 inches (91 cm) for ap-
pliances > 100,000 Btuh (30kW).
6 feet (1.83 m)
Not Allowed
Not Allowed
Figure 1
US Installations
2
Outdoor
12 inches (30 cm) above antici-
pated snow level.
6 inches (15 cm) for appliances
≤ 10,000 Btuh (3 kW), 9 inches
(23 cm) for appliances > 10,000
Btuh (3kW) and ≤ 50,000 Btuh
(15kW), 12 inches (30 cm)
for appliances > 50,000 Btuh
(15kW).
*
*
*
*
*
*
*
6 inches (15 cm) for appliances
≤10,000 Btuh (3 kW), 9 inches
(23 cm) for appliances > 10,000
Btuh (3kW) and ≤ 50,000 Btuh
(15kW), 12 inches (30 cm) for
appliances > 50,000 Btuh (15kW)
3 feet (91 cm) above if within 10
feet (3 m) horizontally.
Not Allowed
Not Allowed
2
Caulk
Rising moisture will collect under eaves
If soffit vent is too close,
block off and install new
vent at another location
Inside
corner
6' (1.8 m) caulk
zone
Caulk
4'
(1.2 m)
WARNING
Moisture in the flue gas will condense as it
:
leaves the vent terminal. In cold weather this condensate can
freeze on the exterior wall, under the eaves and on
surrounding objects. Some discoloration to the exterior of
the building is to be expected. However, improper location
or installation can result in severe damage to the structure
or exterior finish of the building
Additional Considerations
1. Do not install water heater under
any patio or deck.
2. To help prevent moisture from freez-
ing on walls and under eaves, do not
locate the water heater on the side
of a building with prevailing winter
winds.
3. To help prevent water lines from
freezing do not locate water heater
on the side of a building with pre-
vailing winter winds.
4. Do not locate water heater too close
to shrubbery, as flue gases may dam-
age them.
5. Caulk all cracks, seams and joints
within six (6) feet (1.8 m) of exhaust
vent.
6. Guard exhaust vent against acciden-
tal contact with people and pets.
7. Install the water heater such that the
air inlet and exhaust vent are above
anticipated snow levels
6'
(1.8 m)
6' (1.8 m)
caulk zone or to edge of
window etc., starting
within 6' (1.8 m)
Caulk
Figure 2

Advertisement

loading

This manual is also suitable for:

Rmtg-53xRutg-53xPtg-53xPh-20rof