Honeywell TrueFRESH Owner's Manual

Honeywell TrueFRESH Owner's Manual

Ventilation system
Table of Contents

Advertisement

Available languages

Available languages

TrueFRESH™ Ventilation System
INCLUDED IN THIS BOX
A
1
B
TrueFRESH™ Ventilation System
OWNER'S GUIDE
INCLUDED IN THIS BOX
A
1
A
2
B
C
1
C
2
C
3
C
4
C
5
TrueFRESH™ Ventilation System
INCLUDED IN THIS BOX
OWNER'S GUIDE
1
A
A
2
INCLUDED IN THIS BOX
AA
B
TrueFRESH™ Ventilation System
A
OWNER'S GUIDE
C
1
C
2
3
C
4
C
5
C
Owner's Guide
Optional Controls:
1. Vision Pro IAQ
3. Dehumidistat H8908
5. W8150 Ventilation Control
B
C
TrueFRESH™ VNT5150H1000 or VNT5150E1000
4. 20/40/60 Minute Boost Control
A
2. True IAQ
TrueFRESH™ VNT5200H1000 or VNT5200E1000
B
C
TrueFRESH™ VNT5150H1000 or VNT5150E1000
69-2481EF-01
C
C
C
A
OPTIONAL CONTROLS SOLD SEPARATELY
C
OPTIONAL CONTROLS SOLD SEPARATELY
OPTIONAL CONTROLS SOLD SEPARATELY
Owner's Guide
C
1
A
B
2
TrueFRESH™ VNT5200H1000 or VNT5200E1000
1. Vision Pro IAQ
Optional Controls:
3. Dehumidistat H8908
2. True IAQ
4. 20/40/60 Minute Boost Control
5. W8150 Ventilation Control
69-2481EF-01
A
TrueFRESH™ VNT5150H1000 or VNT5150E1000
1
TrueFRESH™ VNT5200H1000 or VNT5200E1000
A
2
B
Owner's Guide
C
Optional Controls:
1. Vision Pro IAQ
2. True IAQ
3. Dehumidistat H8908
4. 20/40/60 Minute Boost Control
5. W8150 Ventilation Control
69-2481EF-01
TrueFRESH™ VNT5150H1000 or VNT5150E1000
A
1
TrueFRESH™ VNT5200H1000 or VNT5200E1000
A
2
Owner's Guide
B
Optional Controls:
C
1. Vision Pro IAQ
2. True IAQ
3. Dehumidistat H8908
4. 20/40/60 Minute Boost Control
5. W8150 Ventilation Control
C
C
1
2
OPTIONAL CONTROLS SOLD SEPARATELY
A
2
C
C
3
4
OWNER'S GUIDE
C
5
69-2481EF-01

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell TrueFRESH

  • Page 1 TrueFRESH™ Ventilation System INCLUDED IN THIS BOX OWNER’S GUIDE TrueFRESH™ Ventilation System INCLUDED IN THIS BOX OWNER’S GUIDE TrueFRESH™ VNT5150H1000 or VNT5150E1000 TrueFRESH™ VNT5200H1000 or VNT5200E1000 Owner’s Guide Optional Controls: 1. Vision Pro IAQ 2. True IAQ 3. Dehumidistat H8908 4.
  • Page 2: Installation Checklist

    Installation Checklist Included in This Box A1 TrueFRESH™ VNT5150H1000 or VNT5150E1000 A2 TrueFRESH™ VNT5200H1000 or VNT5200E1000 B Owner’s Guide Control Options (Sold separately) C1 Prestige™ and Prestige™ IAQ Comfort System (wireless) C2 TruelAQ C3 H8908 Manual Dehumidistat C4 VisionPRO and VisionPRO IAQ control...
  • Page 3: Table Of Contents

    NEED HELP? For assistance with this product please visit http://yourhome.honeywell.com or call Honeywell Customer Care toll-free at 1-800-468-1502. Read and save these instructions. ® U.S. Registered Trademark. Patents pending. Copyright © 2011 Honeywell International Inc. All rights reserved. TrueFRESH™ Ventilation System 69-2481EF—01...
  • Page 4: Operation And Main Function

    NOTE: Reverse process occurs in the summer months. System Installation (examples) Independent System Bathroom Control floor Ground floor Fresh air supply hood Exhaust air hood Basement HRV/ERV TrueFRESH™ Ventilation System 69-2481EF—01...
  • Page 5 Operation and Main Function Exhaust at the Source and Supply in the Return Bathroom Control floor Ground floor Fresh air supply hood Exhaust air hood Basement Forced Air HRV/ERV System TrueFRESH™ Ventilation System 69-2481EF—01...
  • Page 6 Operation and Main Function Exhaust and Supply in the Return Bathroom Control floor Ground floor Fresh air supply hood Exhaust air hood Basement Forced Air HRV/ERV System TrueFRESH™ Ventilation System 69-2481EF—01...
  • Page 7: Description

    • Control Panel: Selects your ventilation modes (OFF, CONT or INTER), also to adjust your continuous airflow rates: Increasing (+)/ Decreasing (-). • Synthetic Filters: Capture the largest particle and protects your heat recovery core from potential obstruction by these particles. TrueFRESH™ Ventilation System 69-2481EF—01...
  • Page 8: Control Panel

    NOTE: See Balancing Steps on page 7. Speed Control used as a Motor Control • + Button: Increase the speed of the selected motor. • – Button: Decrease the speed of the selected motor. NOTE: See Balancing Steps on page 7. TrueFRESH™ Ventilation System 69-2481EF—01...
  • Page 9: Balancing Steps

    Press the (+) and (–) buttons simultaneously to exit balancing mode . Speed Control b. Indicator light turns green. c. Continuous speed will be 50% of measured CFM. Open for Instructions 3-POSITION SPEED CONTROL SELECTOR SWITCH BUTTONS (+ AND -) M32371 TrueFRESH™ Ventilation System 69-2481EF—01...
  • Page 10: Operating Your Wall Controls

    Manual Dehumidistat (H8908DSPST) and Automatic Ventilation Controls (W8150A1000) • Manual humidity control with intuitive comfort settings. • Automatic W8150 ventilation control to ASHRAE standard, or for continuous operation. Boost Control Digital Timer (50053952-020) • Ventilation boost control for 20/40/60 minutes. TrueFRESH™ Ventilation System 69-2481EF—01...
  • Page 11: Troubleshooting

    If the LED light on the ERV/HRV control panel remains green, the green motors do not energize, and the controls do not operate. This can indicate that the Polarization in the main AC outlet is inverted TrueFRESH™ Ventilation System 69-2481EF—01...
  • Page 12 Once a year or as needed, vacuum the four surfaces, let soak in warm water and mild soap for 15 minutes, then spray rinse and let dry. NOTE: See Cleaning Steps on page 11 for the above maintenance items. TrueFRESH™ Ventilation System 69-2481EF—01...
  • Page 13: Cleaning

    3. Clean inside of unit with a damp cloth and wipe 4. Replace the Core and the two filters, re-latch the dry when finished. side panel, then reconnect the AC power to the unit. TrueFRESH™ Ventilation System 69-2481EF—01...
  • Page 14: 5-Year Limited Warranty

    5-Year Limited Warranty Honeywell warrants this product to be free from defects in the workmanship or materials, under normal use and service, for a period of five (5) years from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective or malfunctions, Honeywell shall repair or replace it (at Honeywell’s option).
  • Page 15 Système de ventilation TrueFRESH™ GUIDE DU PROPRIÉTAIRE.. INCLUS DANS CETTE BOÎTE TrueFRESH™ Ventilation System OWNER’S GUIDE INCLUDED IN THIS BOX TrueFRESH™ Ventilation System OWNER’S GUIDE INCLUDED IN THIS BOX OPTIONAL CONTROLS SOLD SEPARATELY TrueFRESH™ VNT5150H1000 or VNT5150E1000 TrueFRESH™ VNT5200H1000 or VNT5200E1000 Owner’s Guide...
  • Page 16 Liste de vérification pour l’installation Inclus dans cette boîte A1 TrueFRESH™ VNT5150H1000 ou VNT5150E1000 A2 TrueFRESH™ VNT5200H1000 ou VNT5200E1000 B Guide du propriétaire Options de régulateurs (vendus séparément) C1 Systèmes Prestige™ et Prestige™ IAQ Comfort (sans fil) C2 TruelAQ C3 Déshumidistat manuel H8908 C4 Régulateurs VisionPRO et VisionPRO IAQ...
  • Page 17 à la clientèle de Honeywell au 1-800-468-1502. Lisez et conservez ces instructions. ® Marque de commerce déposée américaine. Brevets en instance. Copyright © 2011 Honeywell International Inc. Tous droits réservés. Système de ventilation TrueFRESH™ 69-2481EF—01...
  • Page 18: Fonctionnement Et Fonction Principale

    REMARQUE : le processus inverse se déroule pendant les mois d’été. Installation du système (exemples) Système indépendant Salle de bains Étage du régulateur Rez-de-chaussée Hotte d’alimentation en air frais Hotte d’évacuation de l’air Sous-sol VRC/VRE Système de ventilation TrueFRESH™ 69-2481EF—01...
  • Page 19 Fonctionnement et fonction principale Évacuation à la source et alimentation dans le circuit de retour Salle de bains Étage du régulateur Rez-de-chaussée Hotte d’alimentation en air frais Hotte d’évacuation de l’air Sous-sol Système VRC/VRE d’air forcé Système de ventilation TrueFRESH™ 69-2481EF—01...
  • Page 20 Fonctionnement et fonction principale Évacuation et alimentation dans le circuit de retour Salle de bains Étage du régulateur Rez-de-chaussée Hotte d’alimentation en air frais Hotte d’évacuation de l’air Sous-sol Système VRC/VRE d’air forcé Système de ventilation TrueFRESH™ 69-2481EF—01...
  • Page 21: Description

    • Air frais provenant de l’orifice extérieur (A) : Augmentation (+)/Diminution (-). entrée d’air frais extérieur. • Filtres synthétiques : capturent les particules les plus grosses et protègent votre noyau de récupération de chaleur d’obstructions potentielles dues à ces particules. Système de ventilation TrueFRESH™ 69-2481EF—01...
  • Page 22: Panneau De Commande

    Régulateur de vitesse utilisé comme commande de moteur • Touche + : augmente la vitesse du moteur sélectionné. • Touche – : diminue la vitesse du moteur sélectionné. REMARQUE : voir les Étapes de l’équilibrage à la page 7. Système de ventilation TrueFRESH™ 69-2481EF—01...
  • Page 23: Étapes De L'équilibrage

    Le voyant devient vert. c. La vitesse continue sera égale à 50 % de la Open for Instructions valeur pi³/min mesurée. SÉLECTEUR À TOUCHES DE RÉGULATION 3 POSITIONS DE LA VITESSE (+ ET -) MF32371 Système de ventilation TrueFRESH™ 69-2481EF—01...
  • Page 24: Utilisation De Vos Régulateurs Muraux

    • Régulateur d’humidité manuel avec réglages de confort intuitifs. • Régulateur de ventilation automatique W8150 conforme aux normes ASHRAE ou pour un fonctionnement en continu. Minuterie numérique de régulation de la suralimentation (50053952-020) • Régule la suralimentation de la ventilation pendant 20/40/60 minutes. Système de ventilation TrueFRESH™ 69-2481EF—01...
  • Page 25: Dépannage

    Si la diode du panneau de commande VRE/VRC reste verte, reste verte les moteurs ne sont pas mis sous tension et les régulateurs ne fonctionnent pas. Ceci peut indiquer que la polarité de la prise de courant CA principale est inversée Système de ventilation TrueFRESH™ 69-2481EF—01...
  • Page 26 Une fois par an ou en fonction des besoins, aspirez les quatre surfaces, laissez-les tremper dans une solution d’eau chaude et de savon doux pendant 15 minutes, puis rincez et laissez sécher. REMARQUE : voir les Étapes de nettoyage de la page 11 pour les points d’entretien ci-dessus. Système de ventilation TrueFRESH™ 69-2481EF—01...
  • Page 27: Nettoyage

    3. Nettoyez l’intérieur de l’unité à l’aide d’un chiffon 4. Replacez le noyau et les deux filtres, verrouillez humide et séchez-le lorsque vous avez terminé. le panneau latéral et reconnectez la prise de courant CA à l’unité. Système de ventilation TrueFRESH™ 69-2481EF—01...
  • Page 28: Garantie Limitée De 5 Ans

    Garantie limitée de 5 ans Honeywell garantit ce produit contre tout vice de fabrication ou de matière dans la mesure où il en est fait une utilisation et un entretien convenables, et ce, pour cinq (5) ans à partir de la date d’achat par le consommateur.

Table of Contents