Download Print this page

Connections; Intercom Cpu Pit - Honeywell PIT User Manual

Intercom keyboard remote extender

Advertisement

2.1 CONNECTIONS

2.1.1 Intercom CPU PIT

The RS422 slave port of this PIT connects pin to pin to the Intercom CPU BossWare
master port. Due to the master / slave connection, pin to pin connections are required.
Pin Number
1
2
3
4
5
6
7
8
9
The RS232 master port connects to the keyboard PIT RS232 master port. As both ports
have "master" pin-outs, it is necessary to swap the TXD and RXD lines.
It is only necessary to connect pins 2,3 and 5 as follows:
Intercom CPU PIT Pin
Number
2
3
5
Rev. 1
RS422 Receive data [-] (from BossWare master RS422 Tx[-])
RS422 Receive data [+] (from BossWare master RS422 Tx[+])
RS422 Transmit data [+] (to BossWare master RS422 Rx[+])
RS422 Transmit data [-] (to BossWare master RS422 Rx[-])
RS422 Communications common
Power Supply +
N/C
N/C
Power Supply Common
Pin Number
1
Internally connected to pins 4 and 6
TXD (data to slave device RXD)
2
RXD (data from slave device TXD)
3
4
Internally connected to pins 1 and 6
5
GND
Internally connected to pins 4 and 6
6
CTS (from slave device RTS)
7
8
RTS (to slave device CTS)
9
N/C
Keyboard PIT Pin Number
3
2
5
Pin Function
Pin Function
Intercom CPU PIT Pin
Function
TXD
RXD
GND
3
Keyboard PIT Pin Function
RXD
TXD
GND
900.0405