INSTALLATION

This section gives step-by-step instructions about how to install
the EtherNav" D-GES7600 switch:

Selecting a Site for the Switch

As with any electric device, you should place the switch where it will not be subjected to
temperatures, humidity, or electromagnetic interference above the rated specifications.
The site you select should meet the following requirements:
- The ambient temperature should be between –40 to 74 degrees Celsius.
- The relative humidity should be less than 95 percent, non-condensing.
- Surrounding electrical devices should not exceed the electromagnetic field
(RFC) standards for EIC 801-3, Level 2 (3V/M) field strength.
- Make sure that the switch receives adequate ventilation. Avoid blocking the
ventilation holes on all sides of the switch.

Methods for Mounting the D-GES7600

Several mounting configurations are available for the variety of applications for which this
switch was designed. Each configuration is described as follows:
Wall or Floor Mounting (-W Option)
The brackets provided will require the removal and re-installation of the cover screws as
shown below.
Bracket
(-W Option)
Note: Insure that all screw are re-installed for adequate stability in mounting.