MD-SR50H/50W/60E/60W
IC401 RH-iX0341AWZZ: System Microcomputer (IX0341AW) (2/3)
Terminal Name Input/Output
Pin No.
Port Name
58
MD1
MD1
59
P23
_PLAY
60
WDTOVF
WDTOVF
61
MD2
MD2
62
RES
_RESET
63
NMI
_NMI
64
STBY
_STBY
65
Vcc
VCC
66
XTAL
XTAL
67
EXTAL
EXTAL
68
Vss
VSS
69
PF7
_DCEXT
70
PF6
PCNT2
71
PF5
PCNT1
72
PF4
RCPCNT
73
PF3
_DINT
74
PF2
_ARQD
75
PF1
_RPLAY
76
IRQ0
_ARQK
77
AVcc
AVCC
78
Vref
VREF
79
AN0
PLVBAT
80
AN1
PLCHK
81
AN2
HKEY2
82
AN3
HKEY1
83
AN4
RKEY
84
AN5
TEMP
85
AN6
CHGCNT
86
DA1
LDVAR
87
AVss
AVSS
88
Vss
VSS
89
P24
PLVOW
90*
TIOCB4
MCMON
91*
P26
P26
92
P27
PLVGN
93
PG0
CHGON
94
PG1
JPNP
95
PG2
_KHOLD
96
PG3
LDON
97
PG4
OPICGA
98
Vcc
VDD
99
P10
DCNT
100
P11
HDON
In this unit, the terminal with asterisk mark (*) is (open) terminal which is not connected to the outside.
Input
Operation mode selection input 1
Input
Unit PLAY button operation detection input
Output
Watch dog timer (not used)
Input
Operation mode selection input 2
Input
Microcomputer hard reset input
Input
Nonmaskable interruption (not used)
Input
Microcomputer standby input (not used)
Positive power supply
Crystal connection terminal
Crystal connection terminal
Ground potential
Input
DC-IN detection input
Output
Vcc supply control output of power IC
Output
Vref supply control output of power IC
Input/Output
Record cir cuit power control output
Input
System LSI interruption
Input
Disk cap opens and closes detection/it is started and required
Input
Remote control PLAY key operation detection
Input
It is started by the button input, requirement
A/D and D/A converter positive power supply
A/D and D/A converter reference voltage
Input
Battery voltage detection input
Input
Power supply circuit abnormal detection input
Input
Unit key operation detection input 2
Input
Unit key operation detection input 1
Input
Remote control key operation detection
Input
Ambient temperature detection inputinput
Output
Charging current control output
Output
P.U. laser power setting output
A/D and D/A converter ground potential
Ground potential
Output
Battery voltage measurement
Output
Internal openation status monitor
Output
Spare
Output
Battery voltage detection gain select output
Output
Ni-MH Battery charge ON output
Input
Kana conversion/Kana input existencel nonexistence discrimination
Input
Unit key hold switch input
Output
P.U. laser ON/OFF control output
Output
P.U. detection sensitivity switching output
Positive power supply
Output
Mechanism driver enable output
Output
Recording head current control output
– 36 –