1. GENERAL
a.
The Alpha Easy-Flue is suitable for straight horizontal flues only and can be extended up to the maximum lengths
given in Fig. 1 and 2.
b.
The Easy-Flue includes a 90° bend, (no separate 90° bend is required).
c.
Ensure that there is a slight downward slope of the flue to outside.
d.
The flue system must be installed in accordance with BS 5440:1.
e.
The Easy-Flue is suitable for use in the flue length ranges given in Fig. 1 and 2.
Fig. 1 - Rear Flue
Note: Where the length is less than the minimum or more than the maximum, refer to Appendix 2.
(Kit Part No. 6.1000382)
KIT CONTENTS
Fig. 2 - Side Flue

Advertisement

loading

Summary of Contents for Alpha Alpha Top Easy-Flue 1000 mm

  • Page 1: Installation Instructions

    KIT CONTENTS 1. GENERAL The Alpha Easy-Flue is suitable for straight horizontal flues only and can be extended up to the maximum lengths given in Fig. 1 and 2. The Easy-Flue includes a 90° bend, (no separate 90° bend is required).
  • Page 2: Installation

    Secure the 90° bend to the boiler using the clamp and rubber seal. Ensure that the seal covers the bend and adaptor joint. See Fig. 6. Make good the inside and outside walls with the flue collars. See Fig. 6. Note: The second flue collar is supplied with the boiler. Fig. 6 Alpha CB/C/SY Top Easy-Flue 1000 mm...
  • Page 3 Secure the 90° bend to the boiler using the clamp and rubber seal. Ensure that the seal covers the bend and adaptor joint. See Fig. 9. Make good the inside wall by pushing the inside collar up to the wall. Fig. 9 Alpha CB/C/SY Top Easy-Flue 1000 mm...
  • Page 4 Up to Max:- 3865 mm (CB/SY) 3855 mm (CB/SY) Alpha 750 flue extension (Part No. 6.1000320) is required to extend the range of the telescopic flue. Refer to Appendix 3 for instructions on how to extend the flue. 2865 mm (C23/27)
  • Page 5 Duct B fitted, will not be more than that given in Appendix 2. Note: To gain the correct length, only cut the flue extension ducts (ensure that the cuts are square, free from burrs and the ducts are not distorted). Do Not cut the Easy-Flue ducts. Alpha CB/C/SY Top Easy-Flue 1000 mm...
  • Page 6 These instructions have been carefully prepared but we reserve the right to Nepicar House, London Road, Wrotham Heath, alter the specification at any time in the interest of product improvement. Sevenoaks, Kent TN15 7RS © Alpha Therm Limited 2004. Tel: 0870 3001 964 email: info@alphatherm.co.uk website: www.alpha-innovation.co.uk Part No.