6. Technical point
3) The other water level data
The water data unter each conditon
1st water supply (only preparation)
Overflow error
Bubble
detectingatwashing/rinse/dehydrating
Bubble detecting rinse water level
Water level which can open door
Water level which can drive heater
Water level which can reset the drain
※ If water level is 15KHZ below or 30 KHZ above , sensor-pressur is out of order so needs changing.
24.60
1st water supply level to washing tub
20.50
The water supplied reach 2/3 of door
25.45
Bubble -detecting water level
22.60
The water level which can detect bubbles
24.10 over
It is possible to open the door
24.50(3.5 ℓ )
Safety water level of wash heater
24.50
The water level can be detected after 1st draining
11