Configuring A Boundary Clock - Cisco ME-3600X-24CX Series Manual

Chassis configuration guide
Table of Contents

Advertisement

Chapter 4
Configuring Clocking and Timing
Command
Step 8
sync interval value
Example:
Switch(config-ptp-port)# sync
interval 1
Step 9
announce timeout value
Example:
Switch(config-ptp-port)# announce
timeout 8
Step 10
delay-req interval interval
Example:
Switch(config-ptp-port)# delay-req
interval 1
Step 11
Router(config-ptp-port)# end

Configuring a Boundary Clock

Follow these steps to configure the switch to act as a boundary clock.
OL-27620-01
Purpose
Specifies the sync interval.
Specifies the number of PTP announcement intervals
before the session times out. Valid values are 1-10.
Configures the minimum interval allowed between PTP
delay-request messages when the port is in the master state.
The intervals are set using log base 2 values, as follows:
3—1 packet every 8 seconds
2—1 packet every 4 seconds
1—1 packet every 2 seconds
0—1 packet every second
-1—1 packet every 1/2 second, or 2 packets per second
-2—1 packet every 1/4 second, or 4 packets per second
-3—1 packet every 1/8 second, or 8 packets per second
-4—1 packet every 1/16 seconds, or 16 packets per
second.
-5—1 packet every 1/32 seconds, or 32 packets per
second.
-6—1 packet every 1/64 seconds, or 64 packets per
second.
-7—1 packet every 1/128 seconds, or 128 packets per
second.
Exit configuration mode.
Cisco ME-3600X-24CX Series Switch Chassis Configuration Guide
Configuring Clocking and Timing
4-7