ADTRAN 1200105L2 User Manual
ADTRAN 1200105L2 User Manual

ADTRAN 1200105L2 User Manual

E&m+ dual voice option module e&m+ dual voice plug-on board
Table of Contents

Advertisement

Quick Links

E&M+ Dual Voice Option Module
E&M+ Dual Voice Plug-On Board
61200105L2-1C
January 1999
Part Numbers
1200105L2
1200105L3
Part Number
1200106L2
1200106L3
User Manual

Advertisement

Table of Contents
loading

Summary of Contents for ADTRAN 1200105L2

  • Page 1 E&M+ Dual Voice Option Module Part Numbers 1200105L2 1200105L3 E&M+ Dual Voice Plug-On Board Part Number 1200106L2 1200106L3 User Manual 61200105L2-1C January 1999...
  • Page 2 901 Explorer Boulevard P.O. Box 140000 Huntsville, AL 35814-4000 (256) 963-8000 © 1999 ADTRAN, Inc. All Rights Reserved. Printed in U.S.A.
  • Page 3 Notes provide additional useful information. Cautions signify information that could prevent service interrup- tion. Warnings provide information that could prevent damage to the equipment or endangerment to human life.
  • Page 4: Important Safety Instructions

    Important Safety Instructions When using your telephone equipment, please follow these basic safety precautions to reduce the risk of fire, electrical shock, or personal injury: Do not use this product near water, such as near a bath tub, wash bowl, kitchen sink, laundry tub, in a wet basement, or near a swim- ming pool.
  • Page 5: Federal Communications Commission

    Warranty and Customer Service ADTRAN will replace or repair this product within five years from the date of shipment if it does not meet its published specifications or fails while in service. For detailed warranty, repair, and return information refer to the ADTRAN Equipment Warranty and Repair and Return Policy Procedure.
  • Page 6: Limited Product Warranty

    Customer or a third party (including, but not limited to, loss of data or information, loss of profits, or loss of use). ADTRAN is not liable for damages for any cause whatsoever (whether based in contract, tort, or otherwise) in excess of the amount paid for the item.
  • Page 7: Table Of Contents

    E&M+ Option Module Specifications ............. 1-3 Physical Description ..................1-4 Chapter 2. Installation .................... 2-1 Unpack and inspect ....................2-1 Shipped by ADTRAN..................2-1 Provided by Customer ..................2-1 Installing the option module .................. 2-2 Modules With Hot Replaceable Label on Back Panel........2-2 Modules Without Hot Replaceable Label on Back Panel ......
  • Page 8 Table of Contents Port Configuration (Port Config) ..............3-5 Mode ......................3-6 Receive Level/Transmission Level Point (RX LVL (TLP)) ....3-6 Transmit Level/Transmit Level Point (TX LVL (TLP)) ......3-6 Fault Response (FAULT RESP) ..............3-7 Port Utility (PORT UTIL) .................. 3-7 Port Test ....................... 3-8 TSU Features Used with E&M+ options .............
  • Page 9: List Of Figures

    List of Figures Figure 1-1. E&M+ Dual Voice Option Module ............1-4 Figure 2-1. Installing Option Module..............2-3 Figure 3-1. TSU 100 Main Menu ................3-2 Figure 3-2. Port Status Submenus................3-3 Figure 3-3. E&M Status Display................3-4 Figure 3-4. View Signaling Bits Display..............3-4 Figure 3-5. Port Configuration Submenus.............3-5 Figure 3-6.
  • Page 10 List of Figures E&M+ Dual Voice Option Module User Manual 61200105L2-1...
  • Page 11: List Of Tables

    List of Tables Table 2-1. E&M Voice Pinout Connection ............2-4 Table 3-1. Port Configuration Parameters ............3-5 Table 3-2. Port Test Parameters................3-8 Table C-1. E&M+ Signaling States.................C-1 61200105L2-1 E&M+ Dual Voice Option Module User Manual...
  • Page 12 List of Tables E&M+ Dual Voice Option Module User Manual 61200105L2-1...
  • Page 13: Chapter 1. Introduction

    JUMPER the plug-in board(Part number 1200105L3) near the rear panel directly to the right of the ADTRAN logo. By plac- ing the jumper across Pins 1 and 2, Type I and Type II E&M signalling is enabled. By placing the jumper across pins 2 and 3, Type V E&M signaling is enabled.
  • Page 14: Functional Description

    Chapter 1. Introduction Functional Description The E&M+ Dual Voice Option Module is designed to fit in the option slot of the TSU 100/120/600 and is subject to its operation and control. The E&M+ option module is configured from the front panel of the TSU 100/120/600 or by an external personal computer (PC) program (T- Watch).
  • Page 15: E&M+ Option Module Specifications

    Chapter 1. Introduction E&M+ Option Module Specifications The E&M+ Dual Voice option module conforms to the fol- lowing specifications: Voice Channels Two (four with plug-on module installed) Transmission Levels TX: +13 to -17 dB TLP , 1 dB steps between -17 db and +6 dB, 7 dB step between +6 dB and +13 dB RX: -17 to +7 dB LP , 1 dB steps...
  • Page 16: Physical Description

    Chapter 1. Introduction Physical Description The E&M+ is an option module which plugs into the op- tion slot in the rear of the TSU 100/120/600. See Figure 1-1. Cover Plate TSU 100/120/600 Option Module Figure 1-1. E&M+ Dual Voice Option Module The E&M+ option module rear panel includes a plastic plug over a cutout for additional connectors.
  • Page 17: Chapter 2. Installation

    Shipped by ADTRAN The following items are included in the ADTRAN ship- ment: • E&M+ Dual Voice option module and/or plug-on board •...
  • Page 18: Installing The Option Module

    Chapter 2. Installation INSTALLING THE OPTION MODULE Before installing the option module, check the back panel for the presence or absence of a Hot Replaceable label on the back panel. Modules With Hot Replaceable Label on Back Panel For ease of replacement, power to the TSU 100/120/600 may be when installing or removing the option mod- ule with a Hot Replaceable label on the back panel.
  • Page 19: Placement Of The Option Module

    Chapter 2. Installation Placement of the Option Module Figure 2-1 represents the action required for proper place- ment of the option module. Remove cover plate from the TSU 100/120/600 rear panel. Slide option module into the rear panel until it is positioned firmly against the front of the TSU 100/ 120/600.
  • Page 20: Power Connection

    Chapter 2. Installation Power Connection Each option module derives power from the base TSU 100/120/600 unit. Power to the TSU 100/120/600 is sup- plied by a captive eight-foot power cord. Wiring The E&M+ Dual Voice option module offers two connec- tors for an analog voice interface.
  • Page 21: Power Up Testing And Initialization

    Chapter 2. Installation POWER UP TESTING AND INITIALIZATION The option module executes a partial self test during the power up sequence, as described in the TSU 100/120/600 manual. A full self test can be activated from the Test menu. No initialization input is required. Any previously configured setting for the option module is restored auto- matically upon power up.
  • Page 22 Chapter 2. Installation E&M+ Dual Voice Option Module User Manual 61200105L2-1...
  • Page 23: Chapter 3. Operation

    Operation Chapter 3 OVERVIEW The E&M+ D is con- (E&M) OICE OPTION MODULE trolled as part of the TSU 100/120/600 using the same methods as described in the user manual. See the TSU 100/120/600 User Manual for descriptions of front panel in- dicators and buttons.
  • Page 24: Figure 3-1. Tsu 100 Main Menu

    Chapter 3. Operation Once the option module is selected, the E&M+ MENUS pear as a subset of, and operate the same as, menus for the TSU 100/120/600. With the cursor on one of the TSU 100/ 120/600 four main menu choices, press or a menu Enter number to display the first two submenu items.
  • Page 25: E&M+ Menu Items

    Chapter 3. Operation E&M+ Menu Items The E&M+ M are accessed from, and operate the ENUS same as, menus for the TSU 100/120/600. The E&M+ items are submenu choices of the TSU 100/120/600 four Main menus, as shown in Figure 3-1 on page 3-2. For in- formation on F and R ACTORY...
  • Page 26: Figure 3-3. E&M Status Display

    Chapter 3. Operation E&M Status There are two information fields, E- and M- LEAD LEAD See Figure 3-3. An Asterisk (*) indicates an item is active. M-LEAD E-LEAD Figure 3-3. E&M Status Display E-Lead An asterisk is present if the E-Lead is being grounded and the Rx A signal bit is equal to 1.
  • Page 27: Port Configuration (Port Config)

    Chapter 3. Operation Port Configuration (Port Config) , a submenu of TSU 100/120/600 ONFIGURATION Main Menu item C , is used to configure the ONFIGURATION E&M+ option module. The following submenu items are used to configure the parameters: • Mode •...
  • Page 28: Mode

    Chapter 3. Operation Mode sets the type of interface and T1 signaling to be used. Choices include: • 4W_E&M (four-wire E&M) 4-wire transmission; uses E-Lead and M-Lead signal- • 2W_ E&M (two-wire E&M) 2-wire transmission; uses E-Lead and M-Lead signal- •...
  • Page 29: Fault Response (Fault Resp)

    (UTIL) displays the current software TILITIES information for each port installed in the unit. This infor- mation is required when requesting assistance from ADTRAN Customer Service or when updates are needed. When P is displayed, place the cursor on it TILITY and press to display the first available port.
  • Page 30: Port Test

    Chapter 3. Operation Port Test , a submenu of the TSU 100/120/600 Main menu item T , activates tests of the selected data ports. Selecting the E&M+ displays tests available for this op- tion module. See Figure 3-7 and Table 3-2. When Port Test is Displayed, place the cursor on it and press to display the first available port.
  • Page 31: Figure 3-8. View Signaling Bits Display

    Chapter 3. Operation 1 kHz Tone This test injects a 1004 Hz sine wave either toward the far end (TX Direction toward the T1 network) or toward the near end (the 2/4-wire interface on the option module). This tone may be used for testing or relative level mea- surements.
  • Page 32: Tsu Features Used With E&M+ Options

    Chapter 3. Operation TSU FEATURES USED WITH E&M+ OPTIONS In addition to the E&M+ menu items, two additional menu items of the TSU 100/120/600 may be operated in conjunction with the E&M+ option module. These are and R ACTORY ESTORE Factory Restore , a submenu of the TSU 100/120/600 ACTORY...
  • Page 33: Appendix A. E&M+ Menu Tree

    E&M+ Menu Tree Appendix A The menu tree for the E&M+ Dual Voice Option Module and Plug-On Board is provided in Figure A-1. 1) PORT STATUS 1) E&M STATUS (E-LEAD, M-LEAD) 2) VIEW SIG BITS (RXA RXB TXA TXB) 1) MODE: 4W_E&M, 2W_E&M, 4W_TO, 2W_TO 2) PORT CONFIG 2) RX LVL (TLP): -17 dB to +7dB 3) TX LVL (TLP): +7 dB to -17dB...
  • Page 34 Appendix A. E&M+ Menu Tree E&M+ Dual Voice Option Module User Manual 61200105L2-1...
  • Page 35: Appendix B. E&M+ Failure Messages

    E&M+ Failure Messages Appendix B FAILURE MESSAGES AT POWER-UP The following messages indicate a probable component failure on the E&M+ Dual Voice option module or plug- on board: E01 - EPROM CS EPROM checksum error E02 - RAM ERR Static RAM error E10 - SIGNALING Failure of signal bit transmission E&M ALARM MESSAGES...
  • Page 36 Appendix B. E&M+ Failure Messages E&M+ Dual Voice Option Module User Manual 61200105L2-1...
  • Page 37: Appendix C. Signaling States

    Signaling States Appendix C SIGNALING STATES Table C-1 describes the signaling states for the E&M+ Dual Voice option module and plug-on board and the DS- 1 PCM stream. Table C-1. E&M+ Signaling States E-LEAD OUTPUT RXA RXB TXA TXB M-LEAD INPUT M-lead IDLE (0 V - Type I/II) (-48 V - Type V)
  • Page 38: Appendix C. Signaling States

    Appendix C. Signaling States E&M+ Dual Voice Option Module User Manual 61200105L2-1...
  • Page 39: Index

    2-1 Connector Type (USOC) RJ-45, wiring connection 2-4 installing the unit, how to 2-2 Customer Service v items, shipped by adtran with unit 2-1 damage inspection 2-1 Limited product warranty vi Loopback 3-9 E&M Alarm messages B-1 E&M Status 3-4...
  • Page 40 return material authorization (RMA) v Run Self Test 3-10 Part Number AMP # 555164-1, wiring connection 2-4 Physical Description, E&M+ option Safety Instructions iv module 1-4 seccessful self test 2-5 pinout, E&M voice pinout connection self test, failed 2-5 self test, successful 2-5 placing the option module 2-3 Set E-lead 3-9 plug-on board menu tree A-1...
  • Page 41 (800) 615-1176 Sales (800) 827-0807 Post-Sale Support Please contact your local distributor first. If your local distributor cannot help, please contact ADTRAN Technical Support and have the unit serial number avail- able. Technical Support (888) 4ADTRAN Repair and Return If ADTRAN Technical Support determines that a repair is needed, Technical Sup- port will coordinate with the Customer and Product Service (CaPS) department to issue an RMA number.

This manual is also suitable for:

1200105l31200106l21200106l3

Table of Contents