Page 1
FXS+ DUAL VOICE OPTION MODULE Part Number 1200080L1 Part Number 1200080L1#HS & FXS+ DUAL VOICE PLUG-ON BOARD Part Number 1200082L1 Part Number 1200082L1#HS USER MANUAL 61200.080L1-1C October 1995...
Physical Description ..................5 Chapter 2. Installation ..................7 Unpack and Inspect ....................7 Shipped by ADTRAN ..................7 Provided by Customer ..................7 Installing the FXS+ Dual Voice Option Module ..........8 Determine Revision Level of TSU 100 / TSU 600 ........8 Modules With Hot Replaceable Label on Back Panel ........
Page 4
Table of Contents Port Configuration Menu Items/Parameters Summary ...... 21 PORT UTIL (Port Utility) ................... 22 Port Test ......................23 1 kHz Tone ..................23 VIEW SIG BITS (View Signaling Bits) .......... 24 SET TX SIGNAL (Set Transmit Signal) ......... 24 SET 2-W OUTPUT (Set 2-Wire Output) ........
Introduction FXS+ DUAL VOICE OVERVIEW The FXS+ Dual Voice (FXS+) option module is one of the option modules available for use with the ADTRAN TSU 100/600. The FXS+ module provides two 2-wire voice-grade interfaces serving as the source of line- current and ringing voltage to a telephone or station interface.
• FXS, PLAR, and Tandem operating modes • Ground Start or Loop Start signaling • Supports analog message-waiting light when used with ADTRAN FXO+ • Wink or Immediate Supervision in Tandem mode • Integral ringback and dial tone generation • Integral 20 Hz ring generator •...
Page 7
Chapter 1. Introduction • Adding the FXS+ plug-on board provides the TSU 100/600 with four voice ports in one option slot • Selectable response during carrier failure • Full V.34 modem connect capability (28.8 kbps) for #HS model • Provides FXS forward disconnect capability •...
Chapter 1. Introduction FXS+ Option Module Specifications The FXS+ Dual Voice option module conforms to the following specifications: Voice Channels 2 (4 with plug-on module installed) Transmission Levels TX: +3 to -5 dB TLP, 1 dB steps RX: 0 to -8 dB TLP, 1 dB steps Frequency Response 300 - 3400 Hz ( 1.0 dB) 2-wire Impedance...
Chapter 1. Introduction Physical Description The FXS+ is an option module which plugs into the option slot in the rear of the TSU 100; see Figure 1-1. Figure 1-1 FXS+ Dual Voice Option Module The FXS+ rear panel includes a plastic plug over a cutout for additional connectors.
FXS+ module back for repair or for verification of damage during shipment. Shipped by ADTRAN The following items are included in the ADTRAN shipment: • FXS+ Dual Voice option module • User Manual...
If the card is to be installed in a TSU 100 or TSU 600 with an earlier software revision, ADTRAN recommends that the TSU first be upgraded to the most recent revision to ensure proper operation with the FXS+. For...
Chapter 2. Installation Modules Without Hot Replaceable Label on Back Panel Power to the TSU 100/600 must be Off when installing or removing the FXS+ Dual Voice option module without a Hot Replaceable label on the back panel. Placement of the Option Module Figure 2-1 represents the action required for proper placement of the option module.
Chapter 2. Installation Wiring The FXS+ Dual Voice option module offers two connec- tors for an analog voice interface. The connector is universal and accepts either an RJ-45 (8 Pin) or an RJ-11 (6 pin modular plug). The pinout is given in Table 2-A. The required wiring connection is: Connector Type (USOC) = RJ-45 Part number = AMP # 555164-1...
Chapter 2. Installation POWER UP TESTING AND INITIALIZATION The FXS+ option module executes an abbreviated self test during the power up sequence, as described in the TSU 100/600 manual. No initialization input is required. Any previously configured setting for the FXS+ is restored automatically upon power up.
Chapter 2. Installation WARRANTY AND CUSTOMER SERVICE ADTRAN will replace or repair this product within five years from the date of shipment if the product does not meet its published specifications or if it fails while in service. For detailed warranty, repair, and return information refer to the ADTRAN Equipment Warranty and Repair and Return Policy Procedure.
Chapter 3. Operation Chapter 3 Operation OVERVIEW The FXS+ module is controlled as part of the TSU 100/600 using the same methods as described in the user manual. See the TSU 100/600 User Manual for descriptions of front panel indicators and buttons. Menu Structure When an option module is installed in the TSU 100/600, the unit adds it to the list of available options...
Chapter 3. Operation Once the option module is selected, the FXS+ menus appear as a subset of, and operate the same as, menus for the TSU 100/600. With the cursor on one of the TSU 100/600 four main menu choices press Enter or a menu number to display the first two submenu items.
Chapter 3. Operation FXS+ MENU ITEMS The FXS+ menus are accessed from, and operated the same as, menus for the TSU 100/600. The FXS+ items are submenu choices of the TSU 100/600 four main menus, as shown in Figure 3-1. For information on Factory Restore and Run Self Test see TSU Features Used With FXS+ Options in this chapter.
Chapter 3. Operation 2W STATUS (2-Wire Status) There are three information fields, Busy, Ringing, and MW (message waiting). See Figure 3-3. An asterisk (*) indicates an item is active. Figure 3-3 2-Wire Status Display Busy An asterisk is present if loop current is flowing through the 2-wire circuit.
Chapter 3. Operation PORT CONFIG (Port Configuration) Port Configuration, a submenu of TSU 100/600 main menu item Configuration, is used to configure the FXS+ option module. The following submenu items are used to configure the parameters: • MODE • RX LVL (TLP) •...
ADTRAN FXO+ on the far end. This feature requires the T-span to be operated on ESF framing. When any port uses this mode in a slot, ringing is scheduled to a common two second on, four second off cadence, for all ports in that slot.
Chapter 3. Operation disconnect supervision. This mode also requires other options to be selected. These options are: supervi- sion, dial tone, loop reverse battery, and ringback. These options are described in detail elsewhere. Ringing cadence for incoming calls is two seconds on, four seconds off.
Chapter 3. Operation Fault Resp (Fault Response) Fault Resp is used to set the 2-wire response to a carrier alarm. For a network alarm, the ground start 2-wire trunk would appear busy if Fault Resp is set to seized. If set to normal, no seizure of a ground start trunk occurs.
Chapter 3. Operation • Ringback This option generates ringback tone towards the T-span when enabled and the FXS+ card is in one of the Tamden modes. This may be needed on some cases when the network does not provide ringback tone.
Utilities (UTIL) displays the current software information for each port installed in the unit. This information is required when requesting assistance from ADTRAN Customer Service or when updates are needed. When Port Utility is displayed, place the cursor on it and press Enter to display the first available port.
Chapter 3. Operation Port Test Port Test, a submenu of the TSU 100/600 Main menu item Test, activates tests of the selected data ports. Selecting the FXS+ displays tests available for this option module. See Figure 3-7 and Table 3-B. 1)NETWORK TESTS 4)TEST 1)1 KHZ TONE...
Chapter 3. Operation VIEW SIG BITS (View Signaling Bits) View Sig Bits is used to view the status of the RX and TX signaling bits in the DS-1 stream. See Figure 3-8. The status of both the A and B bits is displayed. Figure 3-8 View Signaling Bits Display SET TX SIGNAL (Set Transmit Signal)
Chapter 3. Operation TSU FEATURES USED WITH FXS+ OPTIONS In addition to the FXS+ menu items, two additional menu items of the TSU 100/600 may be operated in conjunction with the FXS+ option module. These are Factory Restore and Run Self Test. Factory Restore Factory Restore, a submenu of the TSU 100/600 Main menu item Utilities (UTIL), restores the factory installed...
Appendix A. 2FXS+ Failure Messages Appendix A FXS+ Failure Messages FAILURE MESSAGES AT POWER-UP The following messages indicate a probable component failure on the FXS+ Module: EPROM checksum error E01 - EPROM CS Static RAM error E02 - RAM ERR E03 - RNG FQ HI Ring generator frequency too high E04 - RNG FQ LO...
Appendix B. Signaling States Vs. Mode of Operation Appendix B Signaling States SIGNALING STATES VS. MODE OF OPERATION The four tables in this appendix describe the signaling states for voice card and the DS-1 PCM stream. Ground start signaling is not used in PLAR mode. See Table B-A.
Appendix B. Signaling States Vs. Mode of Operation Ground start signaling provides its own tip ground in response to ring ground in the Tandem Mode. See Table B-B. Table B-B Tandem Mode Switch to FXS+ FXS+ FXS+ Condition 2W Output RX A RX B TX A TX B...
Appendix B. Signaling States Vs. Mode of Operation See Tables B-C and B-D for descriptions of FXS mode for signaling states. Table B-C FXS+ Mode (Loop-Start) FXS+ 2W Input RX A RX B TX A TX B 2W Output (Outgoing call from FXS+) Loop Open No Ringing (Idle) Loop Closed...
Appendix B. Signaling States Vs. Mode of Operation Table B-D FXS+ Mode (Ground Start) FXS+ FXS+ 2W Input RX A RX B TX A TX B 2W Output (Outgoing call from FXS+) No Ring Gnd Loop Open Idle Ring Gnd No Tip Gnd Ring Gnd Loop Closed...
Page 37
Support and have the unit serial number available. Technical Support (800) 726-8663 Repair and Return If ADTRAN Technical Support determines that a repair is needed, Technical Support will coordinate with the Return Material Authorization (RMA) department to issue an RMA number. For information regarding...
Page 38
NOTICE This FXS+ module (Software Revision L and later) includes far-end discon- nect and analog message-waiting features when used with an ADTRAN FX0+ module. The configuration menu structure has been modified to accommo- date these new features. If T -Watch is used to configure this card, version 3.0 or later is needed.