Advertisement

Quick Links

Advertisement

Table of Contents
loading

Summary of Contents for Agilent Technologies All

  • Page 2: Table Of Contents

    OSCILLOSCOPES, ANALYZERS, METERS Oscilloscopes Oscilloscope Probes & Accessories Signal Analyzers EMI/EMC Noise Figure Analyzers Network Analyzers Logic Analyzers System and Protocol Test Bit Error Ratio Testers Optical/Transmission Digital Multimeters Power Meters Electronic Counters LCR & Resistance Meters Component Test Instruments Signal Source Analyzer Dynamic Signal Analyzer...
  • Page 3: Oscilloscopes

    80 GHz • Unique mixed signal scopes with integrated oscilloscope and logic analysis features • MegaZoom technology for fast and deep memory all the time Agilent Offers a Wide Range of Oscilloscopes Model Bandwidth Sample Rate Analog Channels Digital Channels...
  • Page 4 Dual Cursor Accuracy 4% full scale Save and Recall Waveform and Setup Memories All specifications are warranted. Specifications are valid after a 30-minute warm-up Save/recall up to 10 waveforms and configuration setups at anytime period and within ±10°C from firmware calibration temperature.
  • Page 5 Channel 1 and Channel 2. Analog progressive and interlaced video 4.5-inch diagonal color CSTN LCD standards including NTSC, PAL and SECAM. Positive or negative sync Resolution pulse polarity. Modes – all fields, even fields, odd fields or line 5 – 263 320 x 240 pixels within a field Control...
  • Page 6 See your Signals More Clearly 1 MΩ: 13 pF Time Base Accuracy All 3000 Series models have color displays to allow you to quickly 100 ppm identify your signals, and the large size – 15 cm (5.9 in) with 320 x Acquisition Modes 240 resolution –...
  • Page 7 Provides GPIB and RS-232 connectivity and pass/fail output for automatic testing. Warranty Options All models include a standard 1-year warranty. Contact your local sales office for prices of extended warranty options. R-51B-001-3C: 1-year return-to-Agilent warranty, extended to 3-years English URL www.agilent.com/find/products...
  • Page 8 Full-width Pattern Triggering Analog: Up to 4 Channels with 4 GaS/s Sample Rate and 1 GHz Bandwidth Flexible triggering capabilities across all scope and logic channels so you can easily isolate and analyze complex signals in your mixed analog and digital designs.
  • Page 9 MegaZoom III Deep Memory • LXI class C compatible Based on the same technology that powers Agilent’s market leading high end oscilloscopes the deep memory that is available in the 5000 oscilloscope is based on MegaZoom technology. 1 Mpt of MegaZoom...
  • Page 10 Serial Decode C/SPI/CAN/LIN/FlexRay serial bus decode • • Options Battery option • • There is either an upgrade or for pay option available; advanced serial triggering and decode available on 4 or 4+16 – channel models only. English URL www.agilent.com/find/products...
  • Page 11 Inflection occurs at 200 ns/div at 100 s/div memory that is simultaneously fast and deep all the time, unlike 10 GSa/s deep-memory options on alternative scopes. With Agilent oscillo- scopes, you have up to 128 Mpts of MegaZoom deep memory,...
  • Page 12 MSOs allow you to trigger on any combination of analog and digital signals – and on many popular serial bus protocols. You can do all of this with a single, easy-to-use oscilloscope interface.
  • Page 13 All of the 6000 Series are supplied with MegaZoom III technology and MSO models incorporate the seamless integration of 16 logic timing channels. All models can be upgraded with additional memory at any time after purchase and all DSO models can be upgraded to an MSO configuration in your lab as an after purchase product.
  • Page 14 Oscilloscopes 6000 Series Portable Oscilloscopes (cont.) Agilent Portable Oscilloscope Specifications DSO/ MSO6000 Series 601xA 603xA 605xA 610xA Channels 2 (DSO6012A) 2 (DSO6032A) 2 (DSO6052A) 2 (DSO6102A) 4 (DSO6014A) 4 (DSO6034A) 4 (DSO6054A) 4 (DSO6104A) 2 + 16 (MSO6012A) 2 + 16 (MSO6032A)
  • Page 15 10:1 passive probe per scope (analog) channel, MSO includes a 54620-68701 (2 x 8) logic cable, user guide, service manual, programmer’s manual, power cord, accessories storage, front panel cover, one-year warranty, Agilent IO libraries version 14.2 CD Memory and MSO Options...
  • Page 16 Because the 6000L Series Oscilloscope is LXI class C compliant and is 100% com-...
  • Page 17: Oscilloscope Probes & Accessories

    2 Mpts 2 Mpts The above models include: user’s guide, service guide, programmers guide, power code, 10:1 divider passive probe per scope channel, Agilent IO Libraries Suite 14.2, 1 year warranty, GPIB extender, LAN crossover cable, rack mount hardware Standard Probes Included Passive Probes Logic Cable Kit –...
  • Page 18 The open viewing system architecture enables all the standard PC connectivity you are famil- • Unrivaled InfiniiMax active probes and accessories iar with, making it easy to share your work and communicate your results.
  • Page 19 11 ps rms Triggering Source All Channels (Scope Channels 1 – 4 and Logic Channels D0 – D15) & External Modes Edge, glitch, line, pattern, state, delay by time, delay by events, TV & violation triggers (pulse width, setup/hold, and transition) Jitter 8 ps ±...
  • Page 20 Accessories 8000 Series Extensive Application Software The Agilent 8000 Series Infiniium Oscilloscope offers a broad portfolio of add-on applications that enable you to customize your oscilloscope. Agilent engineers have worked with industry experts to create software for the oscilloscope that will offer application specific insight and ultimately save you time.
  • Page 21 N2781A 10 MHz/150 A Current Probe, AC/DC (Requires N2779A attached, giving you accurate insight into your high-speed measurement. Power Supply) Agilent offers a variety of probe tips to help you probe any test point. N2782A 50 MHz/30 A Current Probe, AC/DC (Requires N2779A Power Supply)
  • Page 22 InfiniiMax II probing system will lead to improved measure- ments and increased design margins. • Industry’s only full bandwidth economical lead-free solder-in The signal integrity advantages of Agilent’s Infiniium 80000B probe solution Series Scopes and InfiniiMax Probing System include the industry’s •...
  • Page 23 Inc.) is available for extending the reach of InfiniiMax probes into tight environments or into test chambers (Part number PRP042105-01). Please contact Gore at 1-800-311-3060 or look up international contacts at www.gore.com Operating Temperature Range: 0 to 105°C English URL www.agilent.com/find/products...
  • Page 24 Low speed electrical mask testing for ANSI and ITU standards E2699A My Infiniium Integration Package (Opt 6) Customize Infiniium user interface to launch user-created or 3rd party executable programs E2682A Voice Control Option Hands free operation of the Infiniium Oscilloscope English URL www.agilent.com/find/products...
  • Page 25 Jitter Mode decomposes jitter and amplitude interference into its constituent components and presents jitter data in various insightful displays. Jitter Mode operates at all data rates the DCA-J supports. The 86100C brings several key attributes to jitter analysis: Meeting Your Growing Need for More Bandwidth •...
  • Page 26 Notepad, then can be transferred to the instrument’s hard drive using LAN, Flash drive, or USB devices. Perform these mask conformance tests with convenient user-definable measurement conditions, such as mask margins for guardband testing, number of waveforms tested, and stop/limit actions. English URL www.agilent.com/find/products...
  • Page 27 Jitter Mode operates at all data rates the DCA-J sup- ports, removing the traditional data rate limitations from complex Transitioning from the Agilent 83480A or jitter analysis.
  • Page 28 Pick any 4 rates (155 Mb/s to 8.5 Gb/s). This module is not compatible with the 86100A and 86100B Digital Communication Analyzer (DCA) mainframes. If you would like to upgrade older DCAs contact Agilent Technologies and ask for current trade-in deals.
  • Page 29 ± 2% of channel offset), ± 2% of ±0.4% of full scale ±2.5% of full scale offset (all bandwidths) offset (all bandwidths) ±2 mV ± 3% of (reading- ±2 mV ± 2% of (reading- channel offset), 40 GHz...
  • Page 30 Input Return Loss (HMS-10 connector fully filled fiber) 33 dB 850 nm >13 dB , 1310 nm/1550 nm >24 dB Smallest average optical power required for mask test. Values represent typical sensitivity of NRZ eye diagrams. Assumes mask test with compliance filter switched in. English URL www.agilent.com/find/products...
  • Page 31 DC Offset Range (referenced to center of screen) ±500 mV Input Dynamic Range (relative to channel offset) ±400 mV Maximum Input Signal ±2 V (+16 dBm) Nominal Impedance 50 Ω Reflections (for 30 ps rise time) Electrical Input 3.5 mm (male) English URL www.agilent.com/find/products...
  • Page 32 Input Dynamic Range (relative to channel offset) ±400 mV ±400 mV Maximum Input Signal ±2 V (+16 dBm) ±2 V (+16 dBm) Nominal Impedance 50 Ω — Reflections (for 30 ps rise time) Electrical Input 2.4 mm (male) 1.85 mm (female) English URL www.agilent.com/find/products...
  • Page 33 (#100, 200, 300) (#040) (#101, 200, 300) (#040) Note: Other modules and options available. See the Technical Specifications, p/n 5989-0278EN or www.agilent.com for configuration details. Ordering Information Dual Electrical Channel Modules 86112A Dual 20 GHz Electrical Channels 86100C Infiniium DCA-J Mainframe...
  • Page 34 1132A 5 GHz Iprobe Amplifier These are available from F9 Systems, see www.f9-systems.com 1134A 7 GHz Probe Amplifier Call Agilent for connectivity and probing solutions not listed above. InfiniiMax I Probe Heads Firmware and Software E2675A InfiniiMax Differential Browser Probe Head and Accessories.
  • Page 35 User with 50 ohm termination adapter. Requires the 1142A probe power supply. Requires the 1143A probe offset and power module. Requires N2775A power supply. Requires one or more InfiniiMax probe heads or connectivity kit per amplifier. Requires N2779A power supply. English URL www.agilent.com/find/products...
  • Page 36 Alligator ground lead, qty 2 N2770A N2862/63A Low-cost Passive Probe Family The Agilent N2862A and N2863A low-cost passive probes provide a 10:1 attenuation and features a high input resistance of 10 Mohm. The probes can be adjusted for low-frequency compensation and high-frequency compensation.
  • Page 37 Oscilloscope Probes & Accessories High-Impedance Passive Probes 10400 10400B Passive Divider Probe Family Family The 10400B probe family are reliable general-purpose high perfor- mance passive probes that replace the 10400A family of probes. These probes include a no-slip browser. The crown point of the browser digs in to solder and won’t slip while the pogo pin allows small hand movements without losing contact.
  • Page 38 10:1 10 MOhm, 10 pF 600 MHz 1 MOhm, 12 – 14 pF System bandwidth with 54810A/15A/20A/25A. System bandwidth with all Infiniium scopes. System bandwidth with 54845A. System bandwidth with 54830B/31B/32B/30D/31D/32D/33A/33D, DSO/MSO8064A and DSO/MSO8104A. 1160 Family Replacement Parts PC Board Mini-Probe Sockets...
  • Page 39 2 of the 0.5 mm Wedge probe adapter, 4 of probe adapter for an easy hands-free solution for probing 0.5 and our 0.5 mm IC clips and 10 standard IC clips. All for a price substan- 0.65 mm IC packages. See page 87 for more information.
  • Page 40 PQFP and SOIC SMT packages from 0.5 – 0.8 mm pitch. The thin body allows clips to be mounted side by side for probing adjacent IC pins. They are suitable for use with all Agilent oscilloscope probes and logic analyzers and have a maximum input voltage of ±40 V (dc + peak ac).
  • Page 41 N2773A Power Supply for N2772A 1153A 200 MHz Differential Probe The 1153A is a 200 MHz Differential Probe for use with Agilent Infiniium Oscilloscopes. It is a 1X FET differential probe with 200 MHz bandwidth and 3000:1 CMRR (Common Mode Rejection Ratio).
  • Page 42 Agilent is the only company that has overcome the resonance probing 0.5 mm and 0.65 mm IC packages. See page 87 for more formed by the connection of a probe to a device. The Agilent information. 1156/57/58A probes optimize performance to make your job easier.
  • Page 43 0.5 mm and 0.65 mm IC packages. See page 87 for more information. This probe can access power directly from the 54520/40 series and 54615/16B oscilloscopes. The 1142A power supply is required for all other instruments. This configuration requires 50 Ohm inputs. English URL www.agilent.com/find/products...
  • Page 44 BNC input, 0.2 to 0.5 V/div, and a minimum input impedance of 1 MOhm. 1 mV/100 mA Range; Output Signal: 10 mV/A ac/dc. 1mV/10 mA Range; Output Signal: 100 mV/A ac/dc. Working Voltage: 660 V max., Battery: 9 V alkaline. English URL www.agilent.com/find/products...
  • Page 45 In addition, volt- age offset or temperature drift on the probe can be easily corrected by using the zero adjustment control. English URL www.agilent.com/find/products...
  • Page 46: Signal Analyzers

    Application Note 5989-0552EN Five Applications to Help you Decide Application Note 5989-0526EN Finding Hidden Problems Using Agilent’s Deep-Memory Oscilloscope: How IBM Solved a Mystery Customer Success Story 5988-5655EN The Truth About the Fidelity of High-Bandwidth Voltage Probes Application Note 1404 5988-6515EN...
  • Page 47 Fourier- and radiated emissions. based analyzers can measure dynamic Using any of the PSA Series spectrum signals because they measure all frequen- Signal/Spectrum Analyzers analyzers as the measurement engine, the cies simultaneously, not one at a time.
  • Page 48 Signal Analysis Overview (cont.) Overview Overview Below you will find a condensed comparison guide of Agilent Signal/Spectrum Analyzers. For the full signal/spectrum analyzer capabilities, please see their individual web pages at www.agilent.com or their respective sections in this catalog. 856x ESA-E...
  • Page 49 • • • Removable storage 3.5" floppy Memory card 3.5" floppy 3.5" floppy Option. Future Option. With 89601A VSA software. Device-side only. For complementary signal creation software, see Signal Generators – Signal Studio Software on page 311. English URL www.agilent.com/find/products...
  • Page 50 Signal Analysis Overview (cont.) Dynamic Signal Analyzers Overview Frequency Range Channel Frequency Real-time Dynamic Range Amplitude Model Page Match Resolution in Lines Bandwidth Accuracy* (±) Number 0.000122 Hz to 102.4 kHz ±0.04 dB, ±0.5˚ 100 to 1600 25.6 kHz 80 dB (90 dB typical) 0.15 dB 35670A *Relative accuracy = relative frequency response + lesser of either scale fidelity or IF gain accuracy.
  • Page 51 • FCC Part 15 Subpart F Swept Tuned or FFT Analysis Measurements Beyond Spectrum Analysis With the all-digital IF, the PSA can perform both swept or FFT The PSA Series offers a variety of optional measurement personali- measurements. FFT capability can significantly reduce the sweep ties to expand measurement capability.
  • Page 52 Analyze time-varying signals such as pulsed RF, time division multi- ple access (TDMA), interleaved and burst-modulated signals with gated sweep capability that is now a standard feature of all the PSA Series spectrum analyzers. The gated sweep capability enables the PSA to perform fast and accurate spectrum measurements on burst signals without interference from switching the carrier on and off.
  • Page 53 • adjacent channel power leakage ratio (ACLR) • intermodulation distortion • multi-carrier power • spectrum emission mask • occupied bandwidth • CCDF • power control (PRACH power, slot power and slot phase for UE phase discontinuity) • power versus time English URL www.agilent.com/find/products...
  • Page 54 Perform measurements on uplink and downlink TD-SCDMA signals. the preselector to the PSA using an Agilent approved source. The The measurement personalities, based on the 3GPP TD-SCDMA personality allows the PSA to control settings within the preselector standard UTRA TDD 1.28 Mcps option, provide power and modula-...
  • Page 55 –156 dBc/Hz Span ≥10 Hz, swept 1 µs to 500 ms 10 MHz –156 dBc/Hz –157.5 dBc/Hz Resolution 0.1 µs Sweep (trace) Point Range Span = 0 Hz 2 to 8192 Span ≥10 Hz 101 to 8192 English URL www.agilent.com/find/products...
  • Page 56 31.15 to 35 GHz –152 dBm –156 dBm 35 to 44 GHz –146 dBm –150 dBm 44 to 45 GHz –143 dBm –150 dBm 45 to 49 GHz –143 dBm –146 dBm 49 to 50 GHz –140 dBm –145 dBm English URL www.agilent.com/find/products...
  • Page 57 –96 (10 dB input attenuation, 20 to 30°C, 10 Hz ≤RBW ≤1 MHz, input signal (–10 dBm mixer level) –10 to –50 dBm, all settings auto-coupled except Auto Swp Time = Accy, 13.25 GHz to 25 GHz –100 nominal +90 nominal any reference level, any scale) (–10 dBm mixer level)
  • Page 58 ACPR dynamic range, W-CDMA (5 MHz offset, RRC weighted, 26.5 GHz to 50.0 GHz –85 +12.5 nominal 3.84 MHz noise bandwidth): Preamp on (Option E444xA-1DS, for all models, two –45 dBm tones at Two carriers –70 dB nominal preamp input) Four carriers –68 dB nominal...
  • Page 59 Calibration Cycle Level 5 V TTL The recommended calibration cycle is one year. Calibration services Trigger 2 output Reserved for future applications are available through Agilent service centers. Monitor Output Connector VGA compatible, 15-pin mini D-SUB Input and Outputs Format VGA (31.5 kHz horizontal, 60 Hz vertical...
  • Page 60 For more information on the PSA Series, please visit: www.agilent.com/find/psa Warranty and Service Standard warranty is 1 year R-51B-001-3C 1 Year Return-to-Agilent warranty extended to 3 years Calibration R-50C-001 Standard Calibration R-50C-002 Standards Compliant Calibration E444xA-OBW Service Manual, Assembly Level...
  • Page 61 PSA front panel keys to optimize the modulation analysis. Different speed settings also allow the users for the best The Agilent N5531S measuring receiver is comprised of a PSA compromise between the measurement speed and accuracy. high-performance spectrum analyzer with Option 233 (Built-in measuring receiver personality), a P-series precision power meter (N1911A/12A), and an N5532A sensor module.
  • Page 62 • Linearity: ±(0.009 dB + 0.005 dB/10 dB step) • Relative measurement accuracy: – ±(0.015 dB + 0.005 dB/10 dB step) (nominal) between the residual noise threshold to the maximum measurable level – Range change uncertainty: ±0.031 dB English URL www.agilent.com/find/products English URL www.agilent.com/find/products...
  • Page 63 Digital bandwidths also provide the spectrum analyzer with a full 100 dB on-screen calibrated display. PC Software for 8560EC Series The Agilent BenchLink Spectrum Analyzer PC software provides an easy-to-use communications link between your PC and the 8560EC 8560EC series spectrum analyzers.
  • Page 64 A single coaxial con- 85672A Spurious Response Measurements Utility nection is all you need to measure signals from 30 Hz to 50 GHz. Prese- lection minimizes images and multiple responses at higher frequencies.
  • Page 65 TOI reference to single tone. 2 GHz to 6.6 GHz –10 dBm <–100 dBc 2.0 GHz to 13.25 GHz –10 dBm <–100 dBc 2.0 GHz to 20 GHz –10 dBm <–90 dBc 20 GHz to 25 GHz –10 dBm <–90 dBc English URL www.agilent.com/find/products...
  • Page 66 Dimensions (w/o handle, feet, cover): 187 mm H x 337 mm W x 461 mm D (7.48 in x 13.34 in x 18.44 in) Weight (carrying, nominal) • Agilent 8560EC/62EC/63EC: 16.3 kg (36 lbs) • Agilent 8564EC/65EC: 17.3 kg (38 lbs) English URL www.agilent.com/find/products...
  • Page 67 The 85672A Spurious Response Measurements Utility makes mea- Channel Power surements fast and easy with the touch of a button. Works on all 8560EC series spectrum analyzers. See page 111 for details. The channel power feature quickly provides the user with informa- tion on total power within a specified channel bandwidth, as well as power density within the channel.
  • Page 68 89601A VSA, the two most popular software products for system due to an all digital IF technology, make the MXA ideal for high- designers in the wireless communication industry, in a single instru- volume, low-cost manufacturing.
  • Page 69 (ACP) and noise of test systems. The MXA is an LXI class C compliant signal analyzer power ratio (NPR). You can view all readings of the markers on the that can help you and your team open new possibilities in testing.
  • Page 70 +50 dBm (100 W) input attenuation ≥30 dB Resolution 0.1 us DC volts Sweep (trace) Point Range DC coupled ±0.2 Vdc All spans 1 to 20001 AC coupled ±70 Vdc Time Gating Display Range Gate method Gated LO; Gated video; Gated FFT Log scale 0.1 to 1 dB/division in 0.1 dB steps...
  • Page 71 (10 dB attenuation, 20 to 30°C, 1 Hz ≤RBW ≤1 MHz, input signal Displayed Average Noise Level (DANL) –10 to –50 dBm, all settings auto-coupled except Auto Swp Time = Accy, (Input terminated, sample or averaging type = Log, 0 dB input attenuation, any reference level, any scale, = nominal standard deviation) IF Gain = High, 20 to 30°C.)
  • Page 72 Samples of this product have been type tested in accordance with the Channel Power Agilent Environmental Test Manual and verified to be robust against the Amplitude accuracy, W-CDMA or IS-95 (20 to 30°C, attenuation = 10 dB): environmental stresses of storage, transportation and end-use; those ±0.80 dB (±0.30 dB 95...
  • Page 73 +15 Vdc, ±7% at 150 mA max nominal Agilent MXA Demonstration Guide, p/n 5989-6126EN –12.6 Vdc, ±10% at 150 mA max nominal Select the Right Agilent Signal Analyzer for Your Needs, Selection Guide, USB 2.0 ports p/n 5968-3413E Master (2 ports)
  • Page 74 EXA and MXA signal analyzers including phase noise, noise figure, and analog demodulation The Agilent EXA Economy Signal Analyzer offers unprecedented speed, accuracy, and application cover- age for an economy class instrument. Make Every Millisecond Count...
  • Page 75 (TDMA), interleaved and burst-modulated with N9010A-EFM USB Flash Drive, 512 MB, upgradeable time gating capability. The Agilent EXA offers three types of Time N9010A-DVR USB DVD-ROM/CD-R/RW Drive, upgradeable Gating: Gated LO (or Gated sweep), Gated Video and Gated FFT.
  • Page 76 HSDPA / 8PSK measurement application (N9079A-2FP) 89601X VSA application 1xEV-DO measurement application (N9076A)* cdma2000/cdmaOne measurement application (N9072A) Consult the Agilent website for the latest listing of available measurement applications for both EXA and MXA: www.agilent/find/exa_apps www.agilent/find/mxa_apps * available for order mid-2008...
  • Page 77 EDGE and GSM. But it also offers a wide range of general purpose demodulators for FSK, BPSK, QPSK, offset QPSK, QAM, and VSB, all with user-settable symbol clock rate, bandwidth, filter type and alpha. You can even apply your own proprietary filtering by providing the filter’s impulse or frequency response.
  • Page 78 Link the 89600 VSA software to any Vector Simulink-based designs with Option 106. This option provides a VSA one of a variety of Agilent instruments to sample your signal. Signal block set designed to work with Simulink tool sets and block sets.
  • Page 79 R&D lab and can be signals. They offer FFT based spectrum analysis, wideband flexible directly linked to a wide range of Agilent spectrum analyzers, digital demodulation, and scope-like measurements on RF signals. oscilloscopes and modular VXI systems. This software is provided...
  • Page 80 144 MB/288 MB/1.2 GB signal capture memory option Add a second IF/baseband channel option Add a second RF channel option (89640/41 only) Choice of VXI-mainframe size: 4, 6, 13-slot (not all configurations fit all units) Choice of PC interface: desktop, laptop; also, laptop PC with...
  • Page 81 • Integrated measurements for noise figure and phase noise (opt) E4402B When combined with the communication focused measurement per- sonalities or the Agilent 89601 VSA software, this express analyzer • RMS, quasi-peak, peak detectors and EMI bandwidths are E4404B available makes a powerful tool for communications device development.
  • Page 82 Agilent’s IO Libraries Suite E4411B E4403B The ESA has a wide selection of detectors to meet all of your test Agilent’s IO Libraries Suite ships with the ESA series spectrum E4408B needs; including averaging (RMS), peak, negative peak, sample, and...
  • Page 83 Modulation Analysis Options 229 (measurement personality) and COM (communication test analyzer) combine to enable you to measure EVM and other related metrics for all major 2G/3G formats. Constellation and eye diagrams are provided to help verify modulation quality. 89601A VSA Link...
  • Page 84 Guaranteed specifications provided over a wide temperature range of 0 to 55°C. Measurements Made Easy One-button Power Measurements with Quick setup and measurement time with one-button RF power measurements for all major 2G/3G, WLAN, Standards-based Setups and digital video formats.
  • Page 85 8.0 MB Data Storage Provides internal storage of measurement data and setups for future analysis or comparison. Express Analyzer Features and Performance Summary See the ESA data sheet for more specifications and details. (http://cp.literature.agilent.com/litweb/pdf/5968-3386E.pdf) Basic Analyzer Standard Analyzer Communication Test...
  • Page 86 Options 106 and 228 are not available outside of the Option 304 bundle 1DS, 1D5 ESA-L Series Custom Analyzer All custom ESA-L series include a 75 Ω input port Available Models E4411B (9 kHz to 1.5 GHz) Custom configuration not available for E4403B or E4408B...
  • Page 87 Economy Portable Spectrum Analyzer, ESA Series (cont.) E4411B ESA Accessories E4403B Option Description Comments E4408B E4402B Accessory information can be found at: www.agilent.com/find/sa-accessories E4404B ESA Specific Accessories E4405B 12 VDC power cable DC power connection available on every ESA E4407B Hard transit case ESA Series...
  • Page 88 10 Hz resolution bandwidth. The CSA also offers overall amplitude Weight with batteries 8.5 kg accuracy of ±0.5 dB. Now you get all of this capability and more with Weight without batteries 7.5 kg excellent reliability and low service and support costs.
  • Page 89 Internal 10 MHz Reference • Aging rate: ±1 ppm/year • Temperature stability: ±1 ppm The Agilent N9320A RF spectrum analyzer is one of the new prod- • Supply voltage stability: ±0.3 ppm ucts in Agilent low cost RF instrument family, offering excellent...
  • Page 90 The narrowest RBW also means least noise is introduced by N9340A for overall lowest DANL • The Agilent N9340A achieves the lowest SSB phase noise which also helps detect low signals (spurious or noise) close to the carrier which would otherwise be missed English URL www.agilent.com/find/products...
  • Page 91 • Output Flatness: ±3 dB, referenced to 50 MHz, 0 dBm Calibration Cycle: 1 year Temperature Range Operating • Operating: –10°C to +50°C Battery: 0°C to +50°C • Storage: –40°C to +70°C Battery: –20°C to 50°C • Warm-up Time: 30 minute English URL www.agilent.com/find/products...
  • Page 92 Eliminate the need for signal identification at millimeter frequencies. ers, the 8560EC series portable spectrum analyzers, ESA (E4407B) The Agilent 11974 series mixers are preselected from 26.5 to 75 GHz portable mid-performance spectrum analyzers, the 8566B for faster, easier testing of millimeter devices and systems. Pre-...
  • Page 93 50 Ω to 75 Ω or 75 Ω to 50 Ω impedance converter with type-N Noise Figure <7 dB <8.5 dB connectors, operating from DC to 3 GHz. Use the Agilent 11852B Output Power for 1 dB >+6 dBm >+7 dBm typical Option 004 (50 Ω...
  • Page 94 • Preselector filter alignment using external signal source Agilent’s new EMI measurement system offer excellent ampli- • Built-in limiter for conducted emissions protection tude and frequency accuracy across the entire band. Delivering 8192 •...
  • Page 95 With Agilent’s E7400A Series EMC analyzers, you can evaluate perfor- The EMC standard analyzer (option STD) includes all the options listed mance quickly and easily. below. To receive a standard analyzer with a tracking generator order option STG instead of STD.
  • Page 96 Point and click to mark individual signals and add them to a list This high-gain, low-noise preamplifier adds sensitivity for or use the “Add Peaks to List” function to add all the signals above a MIL-STD radiated measurements. Frequency range is 1 to 26.5 GHz.
  • Page 97: Noise Figure Analyzers

    Full Measurement Capability visual indicators on the screen showing the current machine state. Features present in all NFA series noise figure analyzers Easy Measurement Setup • ENR data automatically loaded into NFA series noise figure...
  • Page 98 ±<6 ppm ±<0.01 ppm Settability ±<0.5 ppm ±<0.01 ppm Tuning Accuracy (Start, Stop, Center, Marker) 4 MHz Measurement Bandwidth (default on all models of Noise Figure Analyzer) Frequency Error 10 MHz – 3.0 GHz ±<Reference error + 100 kHz 3.0 GHz – 26.5 GHz ±<Reference error + 400 kHz...
  • Page 99 With handle (max): 222 mm H x 409 mm W x 515 mm D N8975A 10 MHz to 26.5 GHz NFA Series Noise Figure Analyzer Weight (typical, without options) All options, other than those marked with *, can be ordered at any time for N8973A: 15.5 kg use with an instrument.
  • Page 100 12 GHz to 26.5 GHz 14 – 17 dB N4002A SNS Series Noise Source, 10 MHz to 26.5 GHz, nominal ENR 15 dB All of the SNS series noise sources are provided with an APC 3.5 (male) connector as standard. Instrument...
  • Page 101 346B 10 MHz to 18 GHz 346 Series Noise Source nominal ENR 15 dB 346C 10 MHz to 26.5 GHz 346 Series Noise Source nominal ENR 15 dB All of the 346 series noise sources are provided with an APC 3.5 (male) connector as standard.
  • Page 102: Network Analyzers

    All synthesized sweeper. Most Agilent network networks by creating a data model of such network analyzers in the Agilent product...
  • Page 103 (see are improved by several orders of magnitude. Figure 3). All Agilent network analyzers are Agilent network analyzers contain built-in, multi-channel receivers utilizing a refer- Figure 4: Direct measurement of group delay with high-speed computational hardware that can ence channel and at least one test channel;...
  • Page 104 • Advanced automation and flexible options to boost capabilities manufacturing, component test manufac- tures demand fast, accurate measurements. Agilent offers a host of RF and microwave vector network analyzers that are ready to tackle the most challenging active and passive networks, devices, components and subsystems.
  • Page 105 8720ET, 8720ES, 8722ET and 8722ES microwave network analyzers PNA models offer fast and accurate RF component measurements E5070B were discontinued on April 30, 2005. The Agilent 8753ET and 8753ES for both R&D evaluations and production testing. E5071B RF network analyzers were discontinued on October 31, 2006.
  • Page 106 At times measurement parameters need to be calculated math- ematically or processed statistically after data acquisition. The VBA Built-in 2, or 4 test ports provide simultaneous measurement of all is also useful for such post processing. Unique analysis functions are signal paths for components.
  • Page 107 ENA multiport test solution can mea- • 0.004 dBrms (10 MHz to 4.38 GHz at 70 kHz IFBW) sure all the measurement paths required for antenna switch module • 0.006 dBrms (4.38 GHz to 8.5 GHz at 70 kHz IFBW) testing.
  • Page 108 E5062A ENA-L RF Network Analyzer Providing the latest in modern technology and flexibility, the Agilent ENA-L network analyzers provide basic vector network analysis in a wide range of industries and applications such as wireless communication, cable TV, automotive, education, and more.
  • Page 109 The Agilent PNA, PNA-X and PNA-L Series sources. You can choose to connect them via the USB, GPIB, LAN,...
  • Page 110 Simply connect the ECal module to your test ports and let the analyzer control and measure all the standards necessary for full two-port calibration. These modules are controlled directly from the analyzer via a USB connection.
  • Page 111 The PNA can also be configured with waveguide mm-wave heads for banded solutions up to 325 GHz. Typical performance below 45 MHz and above 67 GHz. All N5250A numbers are typical. Typical performance includes retrace and band-switching times with response calibration.
  • Page 112 Includes sweep and retrace time. 20 GHz to 40 GHz — — — — 0.020 0.020 Program executed in the PNA. 40 GHz to 50 GHz — — — — — 0.020 Program executed on an external PC. English URL www.agilent.com/find/products...
  • Page 113 The N5250A 110 GHz system carries a full purchase. one-year on-site warranty (where available). All models are not available in all countries. For more detailed information regarding the 110 GHz network analyzer system, refer to the Key Literature & Web Link Agilent Web site: www.agilent.com/find/pna and download the N5250A Technical...
  • Page 114 N4689A USB Hub N4689A Calibration Software Option 897 Perpetual license for built-in performance test software for N5242A-897 Agilent inclusive calibration Option 898 Perpetual license for built-in performance test software for N5242A-898 standards compliant calibration Calibration Documentation Option 1A7 ISO 17025 compliant calibration...
  • Page 115 Option 225 Description 300 kHz to 20 GHz 4-port standard test set Option 240 1-year return-to Agilent warranty and service 300 kHz to 20 GHz 4-port configurable test set 3-year return-to Agilent warranty and service and extended power range Option 245...
  • Page 116 41901A SMD PI-Network Test Fixture Measurement Parameters: Gain (Amplitude Ratio), Phase, Group-Delay, Amplitude, Gain-Phase, Gain-Delay, Impedance, Admittance 41901A-010 to 41901A-061 Attachment Kit Display: 6.5 inch TFT Color LCD 11667A 50 Ω Power Splitter Programming: IBASIC 87512A Transmission/Reflection Test Kit English URL www.agilent.com/find/products...
  • Page 117 The • Extremely fast narrowband spectrum measurement stepped FFT is performed for all RBW settings. For example, with • Impedance analysis option and test kit available 100 Hz RBW and 100 kHz span, the 4395A has a sweep time of 300 ms, while swept-tuned spectrum analyzers take a few tens of seconds.
  • Page 118 ±3% basic accuracy @ 23 ± 5°C, after OPEN/SHORT/LOAD calibration 16194A High Temperature Component Test Fixture 16196A/B/C/D Parallel Electrode SMD Test Fixture 16197A Bottom Electrode SMD Test Fixture 16092A Spring Clip Test Fixture 41800A Active Probe 41802A 1 MΩ Input Adapter English URL www.agilent.com/find/products...
  • Page 119 Option 4396B-010. A 7 mm connector is mounted on this kit for easy connection to an appropriate impedance test figure. A wide variety of Agilent test fixtures can be used with the test kit, including the surface-mount-device (SMD) fixtures.
  • Page 120 • Third-Order Intermodulation Distortion (@ ≥10 MHz, –30 dBm, separation >20 kHz): <–75 dBc Other Spurious (@ –30 dBm mixer input, offset ≥1 kHz): <–70 dBc Scale Fidelity: ±0.05 dB @ 0 to –30 dB from ref. level English URL www.agilent.com/find/products...
  • Page 121 Option 4395A-010 (100 kHz to 500 MHz) or the 4396B with Option 75 Ω devices up to 2 GHz with an Agilent network analyzer. The test 4396B-010 (100 kHz to 1.8 GHz). The test port of the 43961A is a 7 mm port of the 87512A is a 50 Ω...
  • Page 122 Transit Cases play. Limit testing reduces test time by letting the analyzer make Agilent offers a complete line of sturdy transit cases in Valise and quick and objective pass/fail decisions. External disk save/recall Tote styles. The cases protect your instrument from shock,...
  • Page 123 8757D Option 002’s internal power calibrator. enhancement. Option 001 changes to a 7-mm connector. Dynamic accuracy refers to measurement accuracy as power varies (in dB) from a 0 dBm reference. 25° ± 5°C, 50 MHz. DC mode, 25° ± 5°C. English URL www.agilent.com/find/products...
  • Page 124 Network Analyzers 8757 System Accessories (cont.) Waveguide Detectors and Detector Adapters Summary R85026A For use with the Agilent 8757 only in either ac or dc detection modes Q85026A Model Frequency Connector Dynamic Return Frequency Dynamic U85026A Range Type Range Loss...
  • Page 125 85022A System Cable Kit 11667A: DC to 18 GHz 11667B: DC to 26.5 GHz The 85022A contains all the BNC and GPIB cables to connect an 11667C: DC to 50 GHz Agilent sweep oscillator (8360 series, 83750, or 83751 synthesized Impedance: 50 Ω...
  • Page 126 8757D to give you maximum flexibility in specifying a system that meets 85025A 0.01 to 18 GHz, Type-N (m) your needs. Consult your local Agilent Technologies sales office if 85025A-001 7-mm Connector you would like assistance. 85025B 0.01 to 26.5 GHz, 3.5 mm (m) 85025D 0.01 to 50 GHz, 2.4 mm (m)
  • Page 127 PNA Series Multiport Network Analysis Solutions N4420B • Full crossbar matrix available at 4-, 6-, 8-, 12-, and 16-ports Agilent Multiport Test Sets Extend Network Analysis • Internal couplers enable the highest accuracy for your multiport N4421B Capabilities to a Greater Number of Test Ports, Increase...
  • Page 128 Traceable mea- surement data, on disk, is shipped with each kit. Verification kits may be recertified by Agilent Technologies. This recertification includes a new measurement of all standards and new data with uncertainties. English URL www.agilent.com/find/products...
  • Page 129 O, S, L (m) and 85059A (f), adapters 1.85 mm 0.010 to 67 Hz Precision 8510, PNA 85058V All coaxial calibration kits are specified from DC to their upper frequency limit. WR-28 26.5 to 40 Precision 8510, 85106, R11645A Waveguide Mechanical Calibration Kits WR-22...
  • Page 130 2.4 mm (f) NMD to 7 mm 85135D calibration kit, or ordered separately. A full detailed list of calibra- 2.4 mm (f) NMD to 7 mm tion kit contents is available from the web site: www.agilent.com/ 7 mm Flexible 2.4 mm (f) NMD to 7 mm...
  • Page 131 11854A 50-ohm BNC Accessory Kit 11856A 75-ohm BNC Accessory Kit 7-16 Adapter Kits 11906A 7-16 to 7-16 Adapter Kit 11906B 7-16 to 50-ohm Type-N Adapter Kit 11906C 7-16 to 7-mm Adapter Kit 11906D 7-16 to 3.5-mm Adapter Kit English URL www.agilent.com/find/products...
  • Page 132: Logic Analyzers

    From 34 up to 9,782 Additional Considerations Probes and accessories; Wide variety of processor, bus, FPGA and protocol solutions; View Scope for integrated measurements and analysis with Agilent oscilloscopes; Optional application and analysis software packages Accessories 1181BZ Testmobile System Cart Key Literature &...
  • Page 133 • View cross-domain measurements, correlated in time • Set up measurements easily and navigate through your data The Agilent 16900 Series logic analysis systems provide high- quickly with the analyzer’s intuitive user interface and touch performance, system-level debugging of digital designs. Configure...
  • Page 134 • Identify problem signals quickly by viewing eye diagrams across ing/state analyzer modules or pattern generator modules to meet all buses and signals simultaneously with eye scan your validation needs. • Capture either single-ended or differential signals •...
  • Page 135 Unleash the Complementary Power of a Logic Verification, Debugging and Stress Testing Analyzer and an Oscilloscope The Agilent 16720A digital pattern generator module for Agilent’s Easily make time-correlated measurements between an Agilent logic 16900 Series logic analysis systems is ideal for the functional testing analyzer and oscilloscope.
  • Page 136 4 GHz (250 ps) timing zoom at 64 K deep. Find anomalies separated in time with memory depths upgradeable to 32 M. You get it all at a price that fits your budget. Models with an integrated pattern generator let you control and monitor real-time system operation.
  • Page 137 16804A ordered separately. Options 16806A www.agilent.com/find/logic_analyzer_probes The following options apply to all 16800 Series logic analyzers: 16821A General Purpose Flying Lead Probe 16800A-102 Front Panel with 15” Display 16822A 17-ch E5383A 16800A-103 Front Panel with 15” Display and Touch Screen...
  • Page 138 E5910A Serial Link Optimizer for Xilinx FPGAs • Gain visibility into the internal activity of your Xilinx FPGAs. Agilent’s Serial Link Optimizer is a software tool that extends the Access up to 128 internal signals for each pin dedicated to debug Xilinx ChipScope Pro Serial IO Toolkit and provides easy-to-use •...
  • Page 139 E5404A Accurate Measurements Start with Reliable Probing Your logic analyzer measurement is only as reliable as your probing. Agilent offers a wide variety of probing accessories that support general-purpose and application specific measurement needs. The Soft Touch Connectorless Samtec probes provide a robust, reliable connection between your Agilent logic analyzer and the system under test.
  • Page 140 Note: E5386A half-channel transition adapter provides transition between probes and 16760A logic analyzer cables. Use to reduce the number of probes and connectors required to run in half-channel mode. Adapter maps even channels to all pins of an E5378A, E5379A, E5387A, E5390A, E5402A, E5405A or E5406A. It supports differential or single-ended clock, differential or single-ended data.
  • Page 141 Ordering Information Contact Agilent if you do not see support for your specific vendor or device. A representative can: • Determine if support is under development • Recommend third parties that design custom solutions • Direct you to information or consultants that can help you design a test solution English URL www.agilent.com/find/products...
  • Page 142 • Simultaneously acquires Tx/Rx bidirectional traffic 16900 Series Logic Analyzer Module • Tracks changes across all speed modes – sleep, low power and 16720A Pattern Generator Module high speed • Displays data and control packets at the protocol level Probe between the N4850A and the Device under Test One of the following for each N4850A.
  • Page 143 B4610A B4630A B4641A Identify problem signals quickly by viewing eye diagrams across all buses and The split Source window displays the source code on top and the inverse- signals simultaneously. assembled trace below. The two traces are time-correlated and track as you scroll.
  • Page 144: System And Protocol Test

    Based on the modular, scalable, multi- Networks (173x Series) accelerate test phases and improve user N2X chassis, the Agilent System The 173x Protocol Analyzers, traffic genera- product robustness. These applications Protocol Tester combines multi-protocol tors and SAN tester help you design, debug,...
  • Page 145 • Exercising the DUT – the fully featured x16 exerciser drives the drop to reproduce system problems DUT to the limits • Multiport testing allows you to stress all slots with the same load • Two-in one: A single stimulus and response solution with the conditions and synchronize the tests exerciser and analyzer •...
  • Page 146 (CRC error, invalid field contents, length mismatch) in software pendent of a system. The passive backplane features 3 independent Other Features busses, all prepared for traffic up to x16 and includes reset, standby • Analyzer to exerciser traffic record and replay power, SSC etc.
  • Page 147 • Automated generation of data link layer packets (DLLPs): ACK/NAK, • Feedback of state transitions performed Init/Update-FC • Timestamp in [ns] for all states • Automatic generation and checking of LCRC and sequence numbers; • Link status indications allows the insertion of incorrect LCRCs into TLPs for testing purposes;...
  • Page 148 Related Literature Publication Number • Captures training sequences, ordered sets, data-link-layer packets and The Agilent Test Portfolio for PCI Express 2.0, Brochure 5989-5594EN transaction-layer packets in both directions simultaneously Agilent E2960B Series for PCI Express 2.0, Brochure 5989-5610N •...
  • Page 149 The Graphical User Interface allows the user to select tests and execute them. There are two main windows available in the GUI. All tests in the corresponding mode are listed with name and descrip- tion relative to the PCI Express Specification. In the description field, tool tips provide a detailed description of each test.
  • Page 150 • Carefully monitors the behavior of the DUT in response to certain Brochure 5988-7780EN error conditions • Agilent Technologies, E2960 Protocol Analyzer and Exerciser for PCI • Connection to protocol analyzer for root cause analysis of failed Express, Data Sheet 5988-8679EN compliance tests •...
  • Page 151 PCI Server during system validation with the Agilent E2928A PCI/PCI-X Series Exerciser & Analyzer The Agilent E2920 PCI/PCI-X Series of Verification Tools is a family of test tools designed to provide an early and extensive insight into PCI/PCI-X-based designs, revealing and solving design problems...
  • Page 152 • Hierarchical data representation for fast problem detection and ✓ E2993A in-depth root cause analysis with report generation External Agilent Logic • Numerable ready-to-go tests: data transfer rate, data efficiency, Analyzer Adapter bus usage, retry rate ✓ FS2104 Future Plus...
  • Page 153 A traditional Fibre Channel test environment includes active is performing. Statistics reported include throughput, latency, test tools that generate traffic conditions needed to test all of the lost frames, CRC errors and sequence errors fabric and equipment capabilities, together with passive protocol analyzers to transparently monitor protocol communications within the network.
  • Page 154 Range: 1 second to 7 days Display Sampling Interval Range: 1 second to 1 hour Test Card Synchronization All measurements are synchronized across all test cards within the SAN Test System Capture Memory (in SAN Tester Application) 32 MB real time memory per port...
  • Page 155 8.3 ns TimeStamp resolution N5543A Portable Laptop System Controller Time Correlation N5544A Standard 1U Rack-mount Server Controller • All analyzers in the same session share the same clock to allow for N5545A High-performance 1U Rack-mount Server Controller time-correlated measurements Option •...
  • Page 156: Bit Error Ratio Testers

    • Differential input and output; SFI-4, SFI-5, Xaui p/n 5988-6960EN The ParBERT 81250 is a modular, flexible and scalable Agilent ParBERT 81250 Measuring a real 43.2 Gb/s eye pattern Product platform with a very comprehensive software and measurement Note, p/n 5988-6625EN suite designed to fit your application needs.
  • Page 157: Specifications

    10, 11, 15, 23, 31 (HW based) (HW based) (pure PRBS) Auto-Synchronization On PRBS and memory based data by: — – Bit synchronization with or without automatic phase alignment – Automatic delay alignment around the start sampling delay English URL www.agilent.com/find/products...
  • Page 158 E4862B Generator Front-end 3.35 Gb/s E4863B Analyzer Front-end 3.35 Gb/s N4874A Generator Module 7 Gb/s N4875A Analyzer Module 7 Gb/s N4872A Generator Module 13.5 Gb/s N4873A Analyzer Module 13.5 Gb/s E4868B 45/43.2 Gbit/s Multiplexer Module E4869B 45/43.2 Gbit/s Demultiplexer Module English URL www.agilent.com/find/products...
  • Page 159 • Built-in, compliant and calibrated jitter injection with >0.5 UI Operation Range (option J10). All in one box: PJ, SJ, RJ, BUJ for stressed eye Internal clock: 620 Mb/s to 12.5 Gb/s (option C13 and G13) or testing of a receiver 7 Gb/s (option C07 and G07) •...
  • Page 160 N4903A-G13 Pattern Generator 150 Mb/s to 12.5 Gb/s N4903A-A01 Bit Recovery Mode N4903A-CTR Compliant and Tunable Loop Bandwidth N4903A-J10 Jitter Sources: RJ, PJ, SJ, BUJ N4903A-J11 SSC Generation N4903A-J12 Automated Jitter Tolerance Compliance Software N4903A-J20 Interference Channel: ISI, Sinusoidal Interference (includes N4915A-002, N4915A-003) English URL www.agilent.com/find/products...
  • Page 161 • Built-in, compliant and calibrated jitter injection with Operation Range >0.5 UI (option J10). All in one box: PJ, SJ, RJ, BUJ for stressed Internal clock: 620 Mb/s to 12.5 Gb/s (option G13) or 7 Gb/s ( option G07) eye testing of a receiver External clock: 150 Mb/s to 12.5 Gb/s (option G13) or 7 Gb/s (option G07)
  • Page 162 Jitter • LAN, USB, GPIB for remote control 9 ps pp typical Transition Time • Compatibility with existing remote commands, e.g. Agilent 71612, <25 ps (10% to 90% and ECL levels) 86130A series and N4900 Series Cross Point Adjust • Color touch screen, Windows XP 20% –...
  • Page 163 BERT and the 81141/42A serial pulse data generator. Key Literature & Web Link www.agilent.com/find/n4916 Ordering Information N4916A De-emphasis Signal Converter, includes one 50 Ohm termination SMA, one 2.4 mm to SMA adapter. No signal cables included. English URL www.agilent.com/find/products...
  • Page 164 850 mVpp typ., single-ended automated manufacturing test of electrical and optical devices 1700 mVpp typ., differential running at speeds between 125 Mb/s and 3.125 Gb/s. It addresses all LVDS common standard speeds via selectable bit rates. 400 mVpp typ., single-ended 800 mVpp typ., differential...
  • Page 165: Optical/Transmission

    2 GHz tuning range. Available with one of a number of factory-set center frequencies in the range of 4 to 11 GHz. The N2099A is part of a family of Agilent PXI products that are focused at providing test equipment for optical transceiver manu- facturers.
  • Page 166 ActiveX drivers provide easy to use software, remote control, and a graphical user interface is provided for manual operation of the module. The N2102A is part of a family of Agilent PXI products that are focused at providing test equipment for optical transceiver manu- facturers.
  • Page 167 1.0625 to 5 Gb/s. • Significantly smaller than a traditional BERT The N2101A is part of a family of Agilent PXI products that are • Fixed internal clock rates 1.0625, 1.25, 2.125, 2.488, 2.5, 4.25, focused on providing cost effective test equipment for optical trans- 5.0 Gb/s...
  • Page 168 50 Mb/s to 4.25 Gb/s. The N2100A is part of a family of Agilent PXI products that are focused on providing test equipment for optical transceiver manu- facturers.
  • Page 169: Digital Multimeters

    Digital Multimeters Overview Overview L4400 Agilent offers a full line of digital multimeters. 34405A U1251A & U1252A 34410A & 34411A Selection Table for Digital Multimeters, Voltmeters Product Type Basic Measurements Additional Measurements Connectivity U1251A NEW! Handheld dc & ac voltage, dc & ac current,...
  • Page 170 10 A 10 A Accuracy 0.8% + 20 counts 0.7% + 20 counts The high performance Agilent U1250A Series handheld digital mul- timeters (DMMs) bring high performance on-the-go for electronic Frequency troubleshooting and validation. Owing to its innovation and credi- Range...
  • Page 171 Both primary and secondary displays are 5 digit on the LCD display. Both Brochure, p/n 5989-6381EN the primary and secondary displays offer a maximum resolution of 50,000 For more information on U1250A Series www.agilent.com/find/U1250A counts. Automatic polarity indication. To watch U1250A Series interactive product showcase Power Consumption www.agilent.com/find/U1250A_showcase...
  • Page 172 PC via USB. The 34405A can also be controlled remotely with industry-standard SCPI commands. For its easy integration into different program- ming environments, the 34405A is shipped with the Agilent IO Library Suite, LabVIEW driver and IVI-COM driver. Specifications DC Specifications Accuracy ±...
  • Page 173 ⁄ digit resolution and calibration temperature 18°C – 28°C. 20% over range on all range except 750 Vac. Specifications are for sinewave inputs >5% of range. Maximum crest factor : 3 at full scale. Additional error to be added as frequency >30 kHz and signal input <10% of range. 30 kHz – 100 kHz: 0.003% of full scale per kHz.
  • Page 174 Note, p/n 5989-5980EN Side-by-Side Comparison: Agilent 34405A and Fluke 45 Digital Multimeter Application Note, p/n 5989-5979EN Migration from the Agilent 34401A to the Agilent 34405A Digital Multimeter Application Note, p/n 5989-5515EN For more information on 34405A: www.agilent.com/find/34405A For driver and software downloads: http://adn.tm.agilent.com/ English URL www.agilent.com/find/products...
  • Page 175 10 mV 100 mV 10 MΩ The clear, logical front panel of the 34401A allows you to easily select all primary measurement functions. Traditional “bench” Input Protection: >1000 V on all ranges functions, such as continuity and diode test, are included. Math Measurement Accuracy: ±(% of reading + % of range)
  • Page 176 Note: –3 dB frequency typically >1 MHz 500 V fuse Maximum Reading Rate: Same as dcV Input Resistance: 1 MΩ ± 2%, in parallel with 100 pF Input Protection: >750 V rms on all ranges AC Current (true rms) Maximum Volt-Hz Product: 8 x 10 Measurement Accuracy: ±(% of reading + % of range);...
  • Page 177 Digital Multimeters Digit Digital Multimeters The Agilent 34410A is a high performance digital multimeter 34410A • 6 digit resolution designed for high speed and precise triggering, offering maximum • 10,000 readings/sec @ 5 digits to the PC versatility for present and future needs. The 34410A is a 6 digit, •...
  • Page 178 1 million readings of volatile memory and triggering capabilities. • 1 M reading memory The 34411A has all the features of the 34410A, plus additional • Analog level and pre/post triggering performance that makes it even more powerful. The 34411A •...
  • Page 179 1 rack unit • 50,000 readings/sec. @4 digits to the PC high size. With all the features of the 34411A, users can take advan- • 1 M reading memory tage of the 34401A/E1412A compatibility mode to easily integrate •...
  • Page 180 Keithley 181 nanovoltmeter. Agilent IntuiLink: Easy Data Access The Included Agilent IntuiLink software allows your captured data to be put to work easily, using PC applications such as Microsoft Excel or Microsoft Word, to analyze, interpret, display, print, and document the data you get from the 34420A.
  • Page 181 10 mA 0.0015 + 0.0002 0.0040 + 0.0002 0.0060 + 0.0002 All resistance specifications are for channel 1 only, after 2-hour warm-up, resolution at 7.5 digits (100 NPLC) with filters off, for 4-wire Ω or 2-wire Ω 100 Ω 1 mA 0.0015 + 0.0002...
  • Page 182 High-Test System Throughput • 1 Hz to 10 MHz bandwidth Faster Testing • Up to 50 readings/s with all readings to specified accuracy • Up to 100,000 readings/s • Choice of sampling or analog true rms techniques • Internal test setups >340/s •...
  • Page 183 1.4. Within 24 hours and ±1°C of last ACAL. Peak (ac+dc) input limited to 3458A-A6J ANSI Z540 Compliant Calibration 5 x full scale for all ranges. Add 2 ppm of reading additional error for Agilent factory 3458A-907 Front-handle Kit traceability of 10 Vdc to US NIST.
  • Page 184 Kelvin Probe set for 4-wire Ohm measurements. Each set contains plugs and have a Sanoprene over-mold for a comfortable grip. Each kit 2 clips. includes one black and one red test lead. English URL www.agilent.com/find/products English URL www.agilent.com/find/products English URL www.agilent.com/find/products English URL www.agilent.com/find/products...
  • Page 185 34171B DMM Terminal Connector A clamp on probe for a wide range of applications such as measuring Provides a convenient and reliable method to connect wires to all ground currents, powers ripple or current distribution in systems. five input terminals on the 34401A, 34410A, 34411A, and L4411A.
  • Page 186: Power Meters

    External Power Supply and Triggering Module to safeguarding sensitive information and measurements. This makes the Agilent U2000 Series suitable to be used in a secure environment. The U2000 Series is a complete solution that simplifies your measurement setup and meets all your measurement needs. No...
  • Page 187 Power Meters U2000 Series USB Power Sensors (cont.) U2000 Low Power Path and High Power Path for Agilent U2000 Series USB Power Sensors Series Sensor Power Range U2000A, U2001A, U2002A, U2004A –60 dBm to +20 dBm Low Power Path: –60 dBm to –10 dBm High Power Path: –10 dBm to +20 dBm...
  • Page 188 CDMA and TDMA 34131A Hard Transit Case signals. When the software is in control of the meter, all the meter 34161A Accessory Pouch functions and pre-defined setups are not relevant as the software 34141A Yellow Soft Carry Case overrides the meter.
  • Page 189 • 300 kHz, 1.5 MHz and 5 MHz video (modulation) bandwidths calibration factors, linearity, and temperature compensation data E9327A • Wide dynamic range sensors are all stored within the E9320 sensor’s EEPROM. • Calibration factors stored in EEPROM Specifications Sensor Max.
  • Page 190 Frequency Range: 9 kHz to 110 GHz, sensor dependent Power Range: –70 dBm to +44 dBm (100 pW to 25 W), sensor dependent Power Sensors: Compatible with all 8480 series and E-series sensors except the E9320A family Single Sensor Dynamic Range •...
  • Page 191 Millimeter-Wave Sensor Calibration A 50 MHz calibration port is included in Agilent waveguide power sensors for calibration with the power meter. This calibration pro- vides traceability to NIST at millimeter-wave frequencies, and it elim- inates the uncertainties due to temperature changes and the variance in making measurements with different meter/sensor combinations.
  • Page 192 11708A is factory set to 30 dB ± 0.05 dB at 50 MHz, traceable to NIST. SWR <1.05 at 50 MHz. per pulse (E) in W – µs according to Pa = 30 – 0.02E. This sensor directly replaces the popular 8484A power sensor. English URL www.agilent.com/find/products...
  • Page 193 Time parameter measurements of pulse rise time, fall time, pulse width, time to positive occurrence and time to negative occurrence are also provided. Sensor Compatibility P-Series power meters are compatible with all Agilent P-Series wideband power sensors, E-series sensors and 8480 series power sensors Key System Specifications and Characteristics...
  • Page 194 N1912A-003 Rear Panel Sensor and Power Reference Connectors N1912A-908 Supplies a One-instrument Rackmount Kit N1912A-909 Supplies a Two-instrument Rackmount Kit N1912A-1A7 Supplies an ISO17025 Certificate of Calibration with Data N1912A-A6J Supplies ANSI Z540 Certificate of Calibration with Data English URL www.agilent.com/find/products...
  • Page 195 18 GHz to 26.5 GHz 5.9% 26.5 GHz to 40 GHz 6.0% an external reference source. Agilent’s patent-pending technology integrates a dc reference source and switching circuits into each Physical Characteristics power sensor, so that you can zero and calibrate the sensor while Dimensions it is connected to a device under test.
  • Page 196: Electronic Counters

    The breadth of the Agilent offering allows The 53131A frequency counter offers high performance for system or bench. the best product to be selected for each application.
  • Page 197 — DVM and GPIB standard, battery optional, –70 dBm to +20 dBm true power meter 53149A 46 GHz 1 Hz –30 dBm — DVM and GPIB standard, battery optional, –70 dBm to +20 dBm true power meter English URL www.agilent.com/find/products...
  • Page 198 200 fully-formatted measurements per second. The counters use per day. the Standard Commands for Programmable Instruments (SCPI) Agilent IntuiLink for counters software turns your PC and protocol, letting you leverage your programming investment across counter into a powerful, easy-to-use measurement system. IntuiLink your measurement system.
  • Page 199 Analysis Automatic limit testing, math (scale and offset), statistics (minimum, maximum, mean, standard deviation). Statistics available on all measurements or only measurements that fall within limits. Measurement Characteristic Frequency range CH 1 & 2: dc – 225 MHz CH 1 &...
  • Page 200 The unique cable-loss-compensation feature (power correction) yields accura- cies and repeatabilities that rival power meters. Best of all, since the frequency of the test signal is measured simultaneously, the diode’s frequency response is automatically adjusted for. And like the latest in diode sensors, deviation from square law is also compensated for.
  • Page 201 Display: Backlit LCD 53152A Sample Rate: User-selectable Fast, Medium, Slow or Hold All measurement specifications are over the full signal ranges of Programming: GPIB and RS-232C, SCPI compatible channels 1 and 2. For full specifications or request a Product Math Functions Overview for the 53150 series microwave counters, please visit our •...
  • Page 202 DVM Specifications The Agilent 53140 series microwave counter/power meter/DVMs have Function: DC volts all the fundamental measurements required to install and maintain Range: ±50 Vdc today’s digital microwave radio links. Rugged field portability and a battery option complete the ensemble. These instruments are also at...
  • Page 203: Lcr & Resistance Meters

    4288A 1 kHz/1 MHz Capacitance Meter 4268A 120 Hz/1 kHz Capacitance Meter The Agilent 4288A 1 kHz/1 MHz capacitance meter offers a high- The 4268A capacitance meter offers the ability to test high value speed with reliable measurements for capacitor testing in the multi-layer ceramic capacitors at a constant large test signal level production lines.
  • Page 204 Weight: 16 kg/0.3 kg (35.2 lb/.66 lb) (typical) (Main Frame/Test Head) 4287A RF LCR Meter Key Literature The Agilent 4287A RF LCR meter offers accurate, reliable and fast measurements from 1 MHz to 3 GHz to improve quality and through- 4287A RF LCR Meter Technical Overview, p/n 5968-5443E put of electronic component testing in production lines.
  • Page 205 (≤72 hours at 23°C ± 5°C) instant a faulty DUT is removed from the handler, so the handler can • GPIB Interface: All control settings, measured values, and always be operated at its full speed. comparator information •...
  • Page 206 Ω, with a basic memorized (≤72 hours at 23°C ± 5°C) accuracy of 0.6%. This wide range allows accurate, high-resistance • GPIB Interface: All control settings, measured values, and measurement of capacitors, relays, switches, connectors, materials, comparator information cables, and PC boards. The grounded device-under-test (DUT) mea- •...
  • Page 207 SHORT 5.6 ms MEDIUM 88 ms The Agilent E4980A Precision LCR Meter offers the highest accura- LONG 220 ms cy and repeatability from 20 Hz to 2 MHz, and supports LAN, USB and GPIB PC connectivity. Unlike competing LCRs, the E4980A E4980A-001 DC Bias Current Output: 100 mA max.
  • Page 208 E4980A-002 Bias Current Interface E4980A-201 Handler Interface E4980A-301 Scanner Interface E4980A-ABA Add Hardcopy User’s Guide E4980A-ABJ Add Hardcopy Users Guide E4980A-1A7 Add ISO 17025 Compliant E4980A-A6J ANSI Z540 Compliant Calibration E4980A-1CM Add Rack Mount Kit English URL www.agilent.com/find/products English URL www.agilent.com/find/products...
  • Page 209 75 kHz to 30 MHz. Whether in research and development, production, quality assurance, or incom- SHORT 30 ms ing inspection, the 4285A will meet all of your LCR meter test and MEDIUM 65 ms measurement requirements.
  • Page 210 Ten additional setups can also be stored/loaded from a memory card. • GPIB: All instrument control settings, measured values, comparator limits, list sweep table, and self-test results. • Memory: The memory buffer can store a maximum of 128 measurement results and output the data over GPIB, ASCII, and 64-bit binary data formats.
  • Page 211 (≤72 hours at 23°C ± 5°C) The 4338B milliohmmeter is a precise, reliable, high-speed test tool • GPIB Interface: All control settings, measured values, and for measurements of low resistance. comparator information •...
  • Page 212: Component Test Instruments

    Impedance analyzers, in • Permittivity ( ) or dielectric constant for addition to all the functions of the LCR electric fields meter, measure impedance, phase, and Impedance Analyzer Selection Guide...
  • Page 213 DC current, and frequency/phase/power transient. Resonator/Filter Test E5100A 10 kHz to 180/300 MHz Network analyzer best fitted for production line especially for resonator and filter manufacturer with fast measurement speed, low noise floor and powerful dedicated commands. English URL www.agilent.com/find/products...
  • Page 214 Note : Refer to the accessory descriptions for frequency and operational limits. Compatible when used in conjunction with 16085B. Do not connect the ground lead to the instrument. 7-mm cable is required. 3.5-mm(m) to 7-mm Adapter is required. English URL www.agilent.com/find/products English URL www.agilent.com/find/products...
  • Page 215 E4991A-010, Probe Station Connection Kit, provides all necessary parts in one option and solves this problem. This option includes extension cables, a connecting plate, and detailed installation procedures. Cascade Microtech is an Agilent channel partner and they provide RF probe stations.
  • Page 216 16196C-710 Add a Magnifying Lens and Tweezers 16196D Parallel Electrodes SMD Test Fixtures 16196D-710 Add a Magnifying Lens and Tweezers 16197A Bottom Electrode SMD Test Fixtures 16197A-001 Add 0201 (inch)/0603 (mm) Device Guide Set English URL www.agilent.com/find/products English URL www.agilent.com/find/products...
  • Page 217 PC boards, substrates, and polymer materials. p/n 5980-1234E When used with the 16453A, the firmware (E4991A-002) built into Agilent Solutions for Measuring Permittivity and Permeability with LCR the analyzer automatically calculates permittivity parameters. The Meters and Impedance Analyzers, p/n 5980-2862EN flexible firmware also lets you display data as a Cole-Cole plot or find relaxation time.
  • Page 218 Electrical Interface: Four-terminal pair performed on a small amount of liquid samples. Key Literature Specifications Agilent Solutions for Measuring Permittivity and Permeability with LCR Operating Frequency: 20 Hz to 30 MHz Meters and Impedance Analyzers, p/n 5980-2862EN Operating Temperature: –20°C to +125°C Sample Size: 3.4 ml to 6.8 ml...
  • Page 219 The equivalent-circuit analysis function provides advanced model- ing (three and four element models) based on circuit constant values The Agilent 4294A precision impedance analyzer is an integrated of five available circuit models. This function simulates the frequen- solution for efficient impedance measurement and analysis of com- cy characteristics of components by using derived circuit values or ponents and circuits.
  • Page 220 110 MHz), p/n 5968-4506E Evaluation of MOS Capacitor Oxide C-V Characteristics Using the DC Bias Agilent 4294A, p/n 5988-5102EN DC Bias Level: 0 V to ±40 V, 0 A to ±100 mA (Auto level control Accurate Impedance Measurement with Cascade Microtech Probe...
  • Page 221: Signal Source Analyzer

    Removable HDD, 2 USB connectors, Probe power connector (+15 V, tions and aerospace & defense applications. –12.6 V, 150 mA maximum), GND terminal This all-in-one solution is designed to provide a significantly accurate and efficient measurement environment with easy-to-use 10 MHz Reference Output on Rear Panel features and excellent PC connectivity in order to improve design Frequency Uncertainty: 0.5 ppm typ.
  • Page 222 E5053A-1A7 ISO 17025 Compliant Calibration E5053A-1CM Rackmount Kit E5053A-1CN Front Handle Kit E5053A-1CP Rackmount and Front Handle Kit E5053A-ABA Add English Manual Set E5053A-ABJ Add Japanese Manual Set E5001A-1FP E5001A Jitter Application – Standard Tier, Fixed, Perpetual License English URL www.agilent.com/find/products English URL www.agilent.com/find/products...
  • Page 223: Dynamic Signal Analyzer

    Everything you need to troubleshoot vibration Key Literature and noise problems in the field is in one instrument. (You can retrofit all options — buy only the functionality you need today and 35670A Rotor Dynamics Measurement Technique, p/n 5966-0518E add more as your needs change.)

Table of Contents