General
7845GSM and 7845i-GSM Communication Modules both come equipped with an internal dual band cellular
antenna. In most cases, this antenna will provide a sufficient received signal strength indication (RSSI) for a
successful installation.
The Honeywell GSM-ANT Indoor Fixed Length Antenna should be used in installations where moving the
antenna to a higher point within the building will provide better RSSI.
Signal Strength
For reliable service, 7845GSM and 7845i-GSM should only be installed in locations where the RSSI is a
minimum of three bars. RSSI is a measure of how well the 7845GSM/7845i-GSM is receiving the cell tower.
The RSSI value measured in dBm can be viewed using the 7720P Programming Tool, by using the shift <E>
command.
dBm is displayed as a negative value on the 7720P and a smaller negative number is better.
i.e., -60 dBm is a better RSSI than -100 dBm.
Installation Guidelines
By following a few simple guidelines, you can maximize the performance of the 7845GSM/7845i-GSM and
simplify your installation.
Find the best coverage before mounting and wiring the radio by moving 7845GSM/7845i-GSM to
several locations while monitoring the RSSI.
The best RSSI can usually be found on an exterior wall at the highest point in the building. Avoid
the basement.
Maintain at least 12 inches of clearance between 7845GSM/7845i-GSM and steel I-beams, HVAC
ducts, metal studs, steel roofs or roofs, exterior walls with metalized insulation or aluminum siding
and other large metal objects.
If a consistent RSSI of three bars cannot be found with the internal antenna, an external antenna should be
used.
External Antenna
The GSM-ANT is not weatherproof, and must be installed indoors and mounted vertically while maintaining
12 inches of clearance from large metal objects. Install the antenna as follows:
1. Measure and record the 7845GSM/7845i-GSM RSSI using the internal antenna for reference.
2. Disconnect all power from the unit, including the battery.
3. Remove plastic plug from the SMA mounting hole on top of the 7845GSM/7845i-GSM, and insert the
SMA end of the adapter cable.
4. Secure the SMA connector with the included washer and nut.
5. Plug the MMCX end of the adapter cable into the external antenna port and route cable as shown in
Figure 1.
6. Find a suitable location that will allow the antenna to be mounted vertically.
7. Route the antenna cable and connect the SMA to the 7845GSM/7845i-GSM.
8. Restore power to the unit, measure the RSSI and compare the new value to the value recorded in
step 1.
9. Adjust the location of the antenna to maximize the RSSI, for at least three bars.
10. Permanently mount the antenna vertically using the included hardware.
Indoor, , , , Fixed Length
Indoor
Indoor
Indoor
Installation Guide
K14372 8/06 Rev. A
AlarmNet GSM- - - - ANT
AlarmNet GSM
AlarmNet GSM
AlarmNet GSM
Fixed Length Antenna
Fixed Length
Fixed Length
ANT
ANT
ANT
Antenna
Antenna
Antenna

Advertisement

loading

Summary of Contents for Honeywell GSM-ANT

  • Page 1 In most cases, this antenna will provide a sufficient received signal strength indication (RSSI) for a successful installation. The Honeywell GSM-ANT Indoor Fixed Length Antenna should be used in installations where moving the antenna to a higher point within the building will provide better RSSI.
  • Page 2: Specifications

    CABLE SIGNAL STRENGTH (RSSI) FUNCTION LED DISPLAY Select a site where signal strength is 3 - 5 bars lit solid. Min. Lit 7845GSM-024-V0 Figure 1 – GSM-ANT Indoor, Fixed Length Antenna Installation SPECIFICATIONS: Type: Dual band, dipole, PCB VSWR: <2:1...

This manual is also suitable for:

Alarmnet gsm-ant