INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
CONNECTING ELECTRIC DRYERS
(cont.)
WARNING:
• Connect
the power
cord to the terminal
block. Each colored
wire should
be connected
to
same color screw. Wire color indicated
on manual
is connected
to the same color screw
in block.
Failure to follow these instructions
may result in a short or overload.
• Grounding
through
the neutral
conductor
is prohibited
for: (1) new branch-circuit
installations,
(2) mobile
homes,
(3) recreational
vehicles,
and (4) areas where
local
codes
prohibit
grounding
through
the neutral
conductor.
Four-wire Connection for Electric Dryers: Direct wire
• A 4-wire connection
is required for all mobile
and manufactured
home installations, as well
as all new construction
after January 1, 1996.
• A UL-listed strain relief is required.
• Use UL-listed 4-wire #10 AWG-minimum
copper conductor
cable.
• Allow at least 5 ft (1.5 m) length to allow for
removal and reinstallation of the dryer.
1" (2.5 cm)
I-_
Ground Wire
5"
(12.7 cm)
_/
Remove 5 inches (12.7 cm) of the outer
covering from the wire. Remove 5 inches
of insulation from the ground wire. Cut off
approximately
11/2inches (3.8 cm) from the
other three wires and strip 1 inch (2.5 cm)
insulation from each wire. Bend the ends of
the three shorter wires into a hook shape.
Terminal
Block
UL-Listed
Relief
UL-Listed
4-Wire
Power Cord
Remove the terminal block access cover
on the upper back of the dryer. Install a
UL-listed strain relief into the power cord
through-hole;
then thread the power cable
prepared in Step 1 through the strain relief.
................................... Hot
-Neutral _Hot
Ground
Ground Wire
Transfer the dryer's ground wire from behind
the green ground screw to the center screw
of the terminal block. Attach the two hot
leads of the power cable to the outer terminal
block screws. Attach the white neutral wire
to the center terminal block screw. Attach the
power cable ground wire to the green ground
screw. TIGHTEN ALL SCREWS SECURELY.
Reinstall the terminal block access cover.
CONNECTING ELECTRIC DRYERS
(cont.)
WARNING:
• Connect
the power
cord to the terminal
block. Each colored
wire should
be connected
to
same color screw. Wire color indicated
on manual
is connected
to the same color screw
in block.
Failure to follow these instructions
may result in a short or overload.
• Grounding
through
the neutral
conductor
is prohibited
for: (1) new branch-circuit
installations,
(2) mobile
homes,
(3) recreational
vehicles,
and (4) areas where
local
codes
prohibit
grounding
through
the neutral
conductor.
_
T#ree-wire Connection for Electric Dryers: Power Cord
• A 3-wire connection
is NOT permitted on new
• Use a 30-amp, 240V, UL-listed
power cord
construction
after January 1, 1996.
with #10 AWG-minimum
copper
conductor
• A UL-listed strain relief is required,
and closed loop or forked terminals with
upturned ends.
Terminal
Block
• UL-Listed
Strain Relief
3-Wire
Power
Remove the terminal block access cover
on the upper back of the dryer. Install a
UL-listed strain relief into the power cord
through-hole;
then thread a UL-listed, 30A,
240V, 3-wire, #10 AWG-minimum
copper
conductor
power cord through the strain
relief.
Ground Win
Attach the two hot leads of the power cord
to the outer terminal block screws. Attach
the neutral wire to the center terminal block
screw. Connect the external ground (if
required by local codes) to the green ground
screw. TIGHTEN ALL SCREWS SECURELY.
Reinstall the terminal block access cover.