Download Print this page

GE WSM2420 Installation Instructions Manual page 5

24"(61cm) electric washer/dryer
Hide thumbs Also See for WSM2420:

Advertisement

Power Supply C ord
Direct Wire
Fire Hazard
Use a new UL listed 30 amp power supply cord.
Use a UL listed strain relief.
Disconnect
power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal
(silver).
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining
2 supply wires to remaining
2 terminals
(gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
Fire Hazard
Use 10 gauge solid copper
wire.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal
(silver).
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining
2 supply wires to remaining
2 terminals
(gold).
Securely tighten
all electrical connections.
Failure to do so can result in death, fire, or
electrical
shock.
1. Disconnect power.
3.
2. Remove the hold-down
screw and terminal block cover.
U
_==:=:::=:==::=_
i
D
Install strain relief.
Style 1: Power supply cord strain relief
Remove the screws from a 3/4"(1.9 cm) UL listed strain relief
(UL marking on strain relief). Put the tabs of the two clamp
sections into the hole below the terminal block opening so
that one tab is pointing up and the other is pointing down, and
hold in place. Tighten strain relief screws just enough to hold
the two clamp sections together.
A. Strain relief tab pointing
up
B. Hole below terminal block opening
C. Clamp section
D. Strain relief tab pointing down
A. Center silver-colored
terminal block screw
B. Hold-down
screw
C. Terminal block cover
D. Internal ground conductor
screw

Advertisement

loading