6 Troubleshooting

CONDITION: No sound, even though
the amp has power. Power LED is on
without flashing and the amp is receiving an
input signal. Signal indicator is flashing.
Speakers not connected.
Open circuit due to speaker failure.
There is a short on the amplifier
output. First disconnect your speakers
from the affected channel(s) one by one
to determine if one of the loads is
shorted.
DC or excessive low-frequency signal at
the amplifier's output has enabled
speaker protection.
"Off/Flashing/On" above means that
the LED can be off, or flashing, or on.
page 18
CTs Power Amplifiers
CTs Power Amplifiers

7 Specifications

CONDITION: Thermal indicator is
flashing.
POSSIBLE REASON:
The amplifier has become too hot for
safe operation. Check for loads less than
2 ohms, and for excessive input levels.
Figure 7.1 CTs 4200
Check for proper ventilation and proper
mode-switch setting. Driving low-
impedance loads while in high-voltage
mode can cause overheating.
CONDITION: All channel thermal
indicators are flashing.
POSSIBLE REASON:
Power supply thermal overload.
CONDITION: No input signal.
(Signal indicator is not flashing even though
audio is applied and channel is ready).
POSSIBLE REASON:
Input signal level is very low.
Input cables have become disconnected.
CONDITION: Bridge LED is flashing.
Figure 7.2 CTs 8200
POSSIBLE REASON:
Power Chart
The mode switch was switched while the
power was on.
Operation Manual
Operation Manual
CTs 4200: MINIMUM GUARANTEED POWER
Dual Mode
Channels Driven
4
1 kHz
20 Hz - 20 kHz
4 Ohm
260
215
8 Ohm
180
190
70V (25 Ohm) at 0.1% THD
220
220*
Power Chart
Bridge-Mono Mode
Channel Pairs Driven
1 kHz
8 Ohm
520
16 Ohm
400
100V (50 Ohm)
at 0.1% THD
220
* Constant Voltage full bandwidth power ratings support 100 Hz - 20 kHz due to automatic high-pass filters.
CTs 8200: MINIMUM GUARANTEED POWER
Dual Mode
Channels Driven
8
1 kHz
20 Hz - 20 kHz
4 Ohm
200
175
8 Ohm
160
155
70V (25 Ohm) at 0.1% THD
200
185*
Bridge-Mono Mode
Channel Pairs Driven
4
1 kHz
8 Ohm
400
16 Ohm
320
100V (50 Ohm) at 0.1% THD
200
* Constant Voltage full bandwidth power ratings support 100 Hz - 20 kHz due to automatic high-pass filters.
(in watts, 0.1% THD) 120VAC, 60 Hz units
2
1
1 kHz
1 kHz
20 Hz - 20 kHz
270
270
225
210
220
210
240
250
245*
2
1
20 Hz - 20 kHz
1 kHz
20 Hz - 20 kHz
430
560
450
380
440
420
220*
250
245*
(In watts, 0.1% THD) 120VAC, 60 Hz units
4
1
2
1 kHz
1 kHz
1 kHz
20 Hz - 20 kHz
250
260
270
230
190
200
220
220
220
240
250
230*
2
1
20 Hz - 20 kHz
1 kHz
1 kHz
20 Hz - 20 kHz
350
500
540
460
310
380
440
440
185*
220
250
230*
page 19