6 Troubleshooting
CONDITION: No sound, even though
the amp has power. Power LED is on
without flashing and the amp is receiving an
input signal. Signal indicator is flashing.
•
Speakers not connected.
•
Open circuit due to speaker failure.
•
There is a short on the amplifier
output. First disconnect your speakers
from the affected channel(s) one by one
to determine if one of the loads is
shorted.
•
DC or excessive low-frequency signal at
the amplifier's output has enabled
speaker protection.
"Off/Flashing/On" above means that
the LED can be off, or flashing, or on.
page 18
CTs Power Amplifiers
CTs Power Amplifiers
7 Specifications
CONDITION: Thermal indicator is
flashing.
POSSIBLE REASON:
•
The amplifier has become too hot for
safe operation. Check for loads less than
2 ohms, and for excessive input levels.
Figure 7.1 CTs 4200
Check for proper ventilation and proper
mode-switch setting. Driving low-
impedance loads while in high-voltage
mode can cause overheating.
CONDITION: All channel thermal
indicators are flashing.
POSSIBLE REASON:
•
Power supply thermal overload.
CONDITION: No input signal.
(Signal indicator is not flashing even though
audio is applied and channel is ready).
POSSIBLE REASON:
•
Input signal level is very low.
•
Input cables have become disconnected.
CONDITION: Bridge LED is flashing.
Figure 7.2 CTs 8200
POSSIBLE REASON:
Power Chart
•
The mode switch was switched while the
power was on.
Operation Manual
Operation Manual
CTs 4200: MINIMUM GUARANTEED POWER
Dual Mode
Channels Driven
4
1 kHz
20 Hz - 20 kHz
4 Ohm
260
215
8 Ohm
180
190
70V (25 Ohm) at 0.1% THD
220
220*
Power Chart
Bridge-Mono Mode
Channel Pairs Driven
1 kHz
8 Ohm
520
16 Ohm
400
100V (50 Ohm)
at 0.1% THD
220
* Constant Voltage full bandwidth power ratings support 100 Hz - 20 kHz due to automatic high-pass filters.
CTs 8200: MINIMUM GUARANTEED POWER
Dual Mode
Channels Driven
8
1 kHz
20 Hz - 20 kHz
4 Ohm
200
175
8 Ohm
160
155
70V (25 Ohm) at 0.1% THD
200
185*
Bridge-Mono Mode
Channel Pairs Driven
4
1 kHz
8 Ohm
400
16 Ohm
320
100V (50 Ohm) at 0.1% THD
200
* Constant Voltage full bandwidth power ratings support 100 Hz - 20 kHz due to automatic high-pass filters.
(in watts, 0.1% THD) 120VAC, 60 Hz units
2
1
1 kHz
1 kHz
20 Hz - 20 kHz
270
270
225
210
220
210
240
250
245*
2
1
20 Hz - 20 kHz
1 kHz
20 Hz - 20 kHz
430
560
450
380
440
420
220*
250
245*
(In watts, 0.1% THD) 120VAC, 60 Hz units
4
1
2
1 kHz
1 kHz
1 kHz
20 Hz - 20 kHz
250
260
270
230
190
200
220
220
220
240
250
230*
2
1
20 Hz - 20 kHz
1 kHz
1 kHz
20 Hz - 20 kHz
350
500
540
460
310
380
440
440
185*
220
250
230*
page 19