Product Features; Wire Reference; 3M-22 Features - Filtrete 3M-22 Install Manual

Hide thumbs Also See for 3M-22:
Table of Contents

Advertisement

3M-22 Features

This thermostat can be used with all millivolt and 24VAC heating and cooling systems. It
cannot be used with line voltage systems. This thermostat is digital and your desired heat or
cool temperatures can easily be set on the large screen with the +/- buttons on the front. A
minimum 4 minute off time protects heating and cooling systems from damage.
This thermostat uses a new technique called sequential staging for more comfort with
faster reaction to requested temperature changes. When using a heat pump with Aux heat, if

Wire Reference

Your Wires
Filtrete Terminal
R or V or VR RH and RC Single power for HEAT and COOL
RH or 4
RC
RC Power for COOL (RH not connected to RC)
W
W2
?
Y
Y COOL control
Y2
Y2 2nd stage COOL control
G or F
G FAN control
C or X
E
L
T
B or
B Heat pump changeover (cool to heat, powered in heat)
O
O Heat pump changeover (heat to cool, powered in cool)
B and O
SEE NOTE
W Heat control
W2 2nd stage HEAT or heat pump auxiliary heat
A 3rd wire for zoned hot water heat (see zoned)
C Common 24VAC power (to power thermostat)
Emergency heat (do not connect, tape off)
System monitor (do not connect, tape off)
Outdoor sensor (do not connect, tape off)
the heat pump cannot keep up and/or is
defective, remove jumper from position 8 and put
jumper on position 6 and the Aux heat will then
be your only source of heat. Be sure to restore it
to PUMP when the pump is again operational as
aux heat is more expensive than pump heat.
RH Power for HEAT (RH not connected to RC)
23
PG
24
PG
B and O
NOTE: If
there are both
B and O wires
(Trane pump
products)
DO NOT
CONNECT B
to B terminal,
connect B to C
terminal