Troubleshooting - Kohler K-13453 Maintenance Manual

Touchless bathroom sink faucet
Table of Contents

Advertisement

Available languages

Available languages

Warranty (cont.)
*Never use cleaners containing abrasive cleansers, ammonia, bleach,
acids, waxes, alcohol, solvents or other products not recommended
for chrome. This will void the warranty.

Troubleshooting

Symptoms
Probable
Causes
1.
No water
A. Filter is
flow.
plugged.
B. Sensor eyes
are dirty.
C. Water not
turned on.
D. Incorrect
installation.
E. The aerator
is plugged.
F. Sensor eyes
are scratched.
G. A flex hose
is kinked.
H. Power was
interrupted.
I. Battery life
expired.
J. Bleed hole
in diaphragm
is plugged or
debris exists
on the seal.
Kohler Co.
Recommended Action
A. Clean or replace the filter.
B. Wipe the sensor eyes with a
damp soft cloth. Wipe dry with a
dry soft cloth.
C. Verify that the water supply is
turned on and that pressure is at
least 20 psi (137 kPa).
D. Verify that the faucet is mounted
as instructed in the installation
guide. Ensure that the sensor eyes
are above the rim of the sink. Refer
to the installation instructions.
E. Remove and clean the aerator.
For calcium/mineral deposits, soak
the plastic insert in a 50:50 mix of
water and vinegar. Soak only the
plastic insert.
F. Replace the sensor assembly.
G. Check the flex hoses to make
certain they are not kinked. If a
flex hose is kinked, disconnect it,
straighten, and reconnect.
H. Wait 2 minutes after power is
restored as the sensor cycles
through the automatic sensing
distance.
I. Replace the power supply.
J. Clean or replace the diaphragm.
11
1124215-5-C

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

K-13462Tk-13469K-13468K-1374K-1375

Table of Contents