G: Power Supply

The OPEN (660) 120/140/150 can either accommodate
an AC power supply or a DC power supply.
G-1: AC P
OWER SUPPLY
The AC power supply used in the OPEN (660) system is a
100 watts forced air cooling power supply. It is a dual
output switching power supply specially designed for the
OPEN (660) system.
G-1-1: I
NPUT
Universal AC input voltage
²
The range of input voltage is from 85V
Input frequency
²
The range of input frequency is between 47Hz to
63Hz.
Input current
²
The maximum input current is 3A at 115 V
at 230 V

Inrush current

²
The inrush current is less than 30A at 115 V
at 230 V
G-1-2: O
UTPUT
Load range
²
Output
Min. load
+5V
+12V
a. At the factory, the +5V output is set between
5.00V to 5.10V at 60% rated load, and the +12V
output is checked to be within the accuracy range.
b. The adjustable range for the +5V output is +/-
5%.
Note: +12V output voltage will track the adjustment.