After the oven is installed
and the gas connected,
all gas connections
MUST be tested for gas leaks.
Be sure that elec-
tricity is off before turning on the gas supply.
Test with pressure
gauge or apply soapy solution
or leak detector
solution
on ALL gas connections.
Repair
any leaks that may appear
before
operating
oven.
THE
REGULATOR
IS SET
FOR
USE WITH
NATURAL
GAS.
FOR
USE WITH
LP GAS,
THE
REG-
ULATOR
MUST
BE CONVERTED.
The gas pressure
regulator
is located
in the compartment
behind
the
control
frame.
Removecontrol
frame
(see instructions
below),
loosen
and slide the control
mounting
plate
out to gain access to the pressure
regulator.
TO REMOVE
CONTROL
FRAME
t
v
(TYPICAL
CONSOLE)
1
Remove
bezel nut from oven light switch
by turning
counterclockwrse
2.
Remove
all other
knobs
by pullrng
straight
forward,
3.
Remove
front
3 Phillips
screws
under
control
frame
and 2 Phillips
screws
on top portlon
of control
frame.
Be sure to hold control
frame
in place.
4.
Pull control
frame
forward.
To convert
the regulator
for LP gas, remove
the regulator
access
cap (see below).
Reverse
cap, so that "LP"
In
cap recess is showing
when
cap is in place. Return
cap to regulator
and tighten.
The regulator
IS
set at 4" water
column
(W-C.) for use with
natural
gas and 10" W.C. for use with
LP gases.
In order
to check
pressure
regulator,
the inlet test pressure
must
be at least one (1") W.C. greater
(5" for natural
and 1 1" for LP) than
setting.
Maximum
pressure
to regulator
must not exceed
14" W.C.
\