Service Precautions

1. Before service, maintenance, or cleaning:
a. Unplug all devices from the generator.
b. Turn the engine switch to its "OFF" position.
c. Allow the engine to completely cool.
d. Then, remove the spark plug
cap from the spark plug.
2. Keep all safety guards in place and in
proper working order. Safety guards include
muffler, air cleaner, mechanical guards,
and heat shields, among other guards.
3. Make sure the Engine Switch is in its "OFF"
position before moving the Generator and
before performing any service, maintenance,
or cleaning procedures on the unit.
4. Keep all electrical equipment clean and dry.
Replace any wiring where the insulation is
cracked, cut, abraded, or otherwise degraded.
Replace terminals that are worn, discolored, or
corroded. Keep terminals clean and tight.
5. Do not alter or adjust any part of the
equipment or its engine that is sealed by the
manufacturer or distributor. Only a qualified
service technician may adjust parts that may
increase or decrease governed engine speed.
6. Wear ANSI-approved safety goggles, heavy-duty
work gloves, and dust mask/respirator during service.
7. Maintain labels and nameplates on the
equipment. These carry important information.
If unreadable or missing, contact Harbor
Freight Tools for a replacement.
For Generator technical questions, please call 1-800-444-3353.
Item 69672 / 69674
For Engine technical questions, please call 1-800-520-0882.
8. Have the equipment serviced by a qualified repair
person using only identical replacement parts.
This will ensure that the safety of the equipment
is maintained. Do not attempt any service or
maintenance procedures not explained in this
manual or any procedures that you are uncertain
about your ability to perform safely or correctly.
9. Store equipment out of the reach of children.
10. Follow scheduled engine and
equipment maintenance.
Refueling:
1. Do not smoke, or allow sparks, flames,
or other sources of ignition around the
equipment, especially when refuelling.
2. Do not refill the fuel tank while the
engine is running or hot.
3. TO PREVENT FUEL LEAKAGE AND FIRE
HAZARD, Do not overfill with fuel. Fill with
fuel according to the Fuel Level information
below the Specification chart for your model.
4. Do not fill fuel tank to the top. Leave a little
room for the fuel to expand as needed.
5. Refuel in a well-ventilated area only.
6. Wipe up any spilled fuel and allow excess
to evaporate before starting engine.
To prevent FIRE, do not start the engine
while the smell of fuel hangs in the air.
SAVE THESE
INSTRUCTIONS.
Page 5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Predator generators 6500 Watt and is the answer not in the manual?

Questions and answers

Carlos
February 10, 2025

Where is fuse box

1 comments:
Mr. Anderson
February 11, 2025

The fuse box location is not explicitly mentioned in the provided context. However, the context does mention a "Case, Fuse Connector" and "Fuse, Rectifier (5A)," which suggests that fuses are part of the control panel assembly. Based on this, the fuse box is likely located near or within the control panel of the Predator 6500 Watt generator.

This answer is automatically generated

Carlos
February 10, 2025

Where is the circuit breaker

1 comments:
Mr. Anderson
February 11, 2025

The circuit breakers are located on the control panel of the Predator 6500 Watt generator. They are used to protect the generator from overloading and are marked near the breaker to indicate the load they protect.

This answer is automatically generated

Carlos
February 10, 2025

Where is circuit braker

1 comments:
Mr. Anderson
February 11, 2025

The circuit breaker is located on the control panel of the Predator 6500 Watt generator. It protects the generator from overloading and is marked near the breaker with its rating and the load it protects.

This answer is automatically generated

Elva
February 21, 2025

My pretador 6500 is used to power my RV but the lights keep dimming . It sounds nice and steady I checked the oil and fuel ect but it's still dimming.

1 comments:
Mr. Anderson
February 21, 2025

Dim lights when using a Predator 6500 Watt generator to power an RV could be caused by several factors:

1. Overloaded Generator – If the total wattage of connected appliances exceeds the generator's capacity, voltage may drop, causing lights to dim.
2. Start-Up Wattage Demand – Appliances with motors, such as air conditioners or refrigerators, require extra power when starting, which can temporarily reduce available voltage.
3. Faulty or Loose Connections – Poor or loose connections between the generator and RV can cause voltage drops, leading to dimming lights.
4. Fuel or Engine Issues – If the generator's engine is not running smoothly due to fuel problems or maintenance issues, it may not produce consistent power.
5. Grounding Problems – If the generator is not properly grounded, it could cause unstable voltage output.

To troubleshoot, check the total load on the generator, ensure proper connections, and verify that the generator is running correctly.

This answer is automatically generated

This manual is also suitable for:

6967269674

Table of Contents

Save PDF