Stopping The Engine Under Normal Conditions - Predator generators 6500 Watt Owner's Manual & Safety Instructions

5500/6500 watt portable generator
Table of Contents

Advertisement

Stopping the Engine in an Emergency
1. To stop the engine in an emergency,
turn the Engine Switch off.
NOTICE: Generator shut-off under load may damage
the generator and attached equipment.

Stopping the Engine Under Normal Conditions

1. Before turning off the Engine,
turn off all electrical loads,
then unplug them.
2. Turn the Engine Switch off.
3. Close the Fuel Valve.
For Generator technical questions, please call 1-800-444-3353.
Item 69672 / 69674
For Engine technical questions, please call 1-800-520-0882.
I
O
OFF
I
O
OFF
Page 13

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Predator generators 6500 Watt and is the answer not in the manual?

Questions and answers

Carlos
February 10, 2025

Where is fuse box

1 comments:
Mr. Anderson
February 11, 2025

The fuse box location is not explicitly mentioned in the provided context. However, the context does mention a "Case, Fuse Connector" and "Fuse, Rectifier (5A)," which suggests that fuses are part of the control panel assembly. Based on this, the fuse box is likely located near or within the control panel of the Predator 6500 Watt generator.

This answer is automatically generated

Carlos
February 10, 2025

Where is the circuit breaker

1 comments:
Mr. Anderson
February 11, 2025

The circuit breakers are located on the control panel of the Predator 6500 Watt generator. They are used to protect the generator from overloading and are marked near the breaker to indicate the load they protect.

This answer is automatically generated

Carlos
February 10, 2025

Where is circuit braker

1 comments:
Mr. Anderson
February 11, 2025

The circuit breaker is located on the control panel of the Predator 6500 Watt generator. It protects the generator from overloading and is marked near the breaker with its rating and the load it protects.

This answer is automatically generated

Elva
February 21, 2025

My pretador 6500 is used to power my RV but the lights keep dimming . It sounds nice and steady I checked the oil and fuel ect but it's still dimming.

1 comments:
Mr. Anderson
February 21, 2025

Dim lights when using a Predator 6500 Watt generator to power an RV could be caused by several factors:

1. Overloaded Generator – If the total wattage of connected appliances exceeds the generator's capacity, voltage may drop, causing lights to dim.
2. Start-Up Wattage Demand – Appliances with motors, such as air conditioners or refrigerators, require extra power when starting, which can temporarily reduce available voltage.
3. Faulty or Loose Connections – Poor or loose connections between the generator and RV can cause voltage drops, leading to dimming lights.
4. Fuel or Engine Issues – If the generator's engine is not running smoothly due to fuel problems or maintenance issues, it may not produce consistent power.
5. Grounding Problems – If the generator is not properly grounded, it could cause unstable voltage output.

To troubleshoot, check the total load on the generator, ensure proper connections, and verify that the generator is running correctly.

This answer is automatically generated

This manual is also suitable for:

6967269674

Table of Contents

Save PDF