Page 2
PM-PRO, PM-PRO-E SPECIFICATIONS Note: Where different, PM-PRO-E specs are in parentheses. Current rating: Input Voltage Range: Meter Accuracy: Spike Protection Modes: Clamping Voltage, all modes: Response time: Maximum surge current: Maximum spike energy: Noise attenuation: Dimensions: Weight: Construction: Power consumption:...
PM-PRO POWER CONDITIONER/MONITOR Safety Information To obtain best results from your Furman PM-PRO, please be sure to read this manual carefully before using it. WARNING: To reduce the risk of electrical shock, do not expose this equip- ment to rain or moisture. Dangerous high voltages are present inside the enclosure.
Page 4
7. Clean the PM-PRO with a damp cloth only. Do not use solvents or abrasive cleaners. Never pour any liquid on or into the PM-PRO. 8. When left unused for a long period of time, the power cord of the PM-PRO should be unplugged from the outlet.
Page 5
PM-PRO Compared to PM-PRO-E The PM-PRO is intended for use with 120 VAC power and is rated at 20 amps; the PM-PRO-E is for 230 VAC power and rated at 16 amps. Outlets on the PM- PRO-E are IEC-320 types. The GROUND OK feature is not available on the PM- PRO-E.
AC voltmeter that continually measures normal voltages. The meter reads from 90 to 128 volts in 2 volt steps (PM-Pro-E: 180 to 256 volts, in 4 volt steps). The normal range voltages are indicated in green, with moderate and...
Page 7
The PM-PRO's voltmeter has a basic accuracy of plus or minus two volts, and extreme cold or heat may cause an additional one volt of error (four volts and two volts for the PM-PRO-E).
LEDs. If it trips, reduce the load on the PM-PRO and push it back to the ON position. (Note: The PM-PRO-E's circuit breaker is not mag- netic.)
Page 9
If this does occur, most likely damage will be limited to the PM-PRO itself and will affect only certain spike suppression components (called varistors or MOV's.) In this "suicide" mode, the...
Repair Stations. This warranty shall be cancellable by Furman at its sole discretion if the PM-PRO unit has been subjected to physical abuse, has been operated without a proper safety ground, or has been modified in any way without written authorization from Furman.